In this Letter, we have developed new and highly efficient periodic multilayer mirrors Al/Sc, Al/Sc/SiC, and Mo/Al/Sc with optimized reflectance at wavelengths between 40 and 65 nm. We have reached record values in measured peak reflectance: 57.5% at 44.
View Article and Find Full Text PDFThis paper demonstrates that highly reflective Cr/B₄C multilayer interference coatings with nanometric layer thicknesses, designed to operate in the soft X-ray photon energy range, have stable reflective performance for a period of 3 years after deposition. The microstructure and chemical composition of layers and interfaces within Cr/B₄C multilayers is also examined, with emphasis on the B₄C-on-Cr interface where a significant diffusion layer is formed and on the oxide in the top B₄C layer. Multiple characterization techniques (X-ray reflectivity at different photon energies, X-ray photoelectron spectroscopy, transmission electron microscopy, electron diffraction and X-ray diffraction) are employed and the results reveal a consistent picture of the Cr/B₄C layer structure.
View Article and Find Full Text PDFDuring the last 10 years, blueberry (Vaccinium corymbosum) production in Uruguay has increased to more than 850 ha. From 2005, symptoms of dieback characterized by the death of twigs and branches have been frequently observed in blueberry plants cv. O'Neal in orchards located in Uruguay.
View Article and Find Full Text PDFPurpose: The purpose of the present study was to compare lag screw fixation versus miniplates with monocortical screw technique with respect to the amount of transverse displacement of the proximal segment after bilateral sagittal osteotomy (BSO) for mandibular advancement surgery.
Patients And Methods: We conducted a multicenter, retrospective investigation of 82 patients who underwent a mandibular advancement with BSO and rigid internal fixation. Forty-five patients from Denmark and Sweden, the miniplate fixation group, received a rigid fixation consisting of miniplates with monocortical screws.
Purpose: The primary purpose of this study is to quantify the kinematics of the temporomandibular joint (TMJ) in patients following unilateral TMJ arthrotomy with metal fossa-eminence partial joint replacement and compare them with TMJ kinematics of healthy individuals.
Materials And Methods: Fourteen healthy volunteers and 13 female surgical patients (minimum 4 years postoperative) participated in this study. An electromagnetic tracking device was used to record the kinematics of the mandible relative to temporal bone during opening-closing, protrusive, and lateral movements.