Our study evaluated the efficacy and feasibility of left bundle branch area pacing (LBBAP) compared to right ventricular outflow tract septal pacing (RVOSP). We conducted a prospective, single-center, observational study involving 200 consecutive patients who required pacemaker implantation. The patients were divided into two groups (LBBAP and RVOSP), with 100 patients in each group.
View Article and Find Full Text PDFIntroduction And Objectives: The multiparametric implantable cardioverter-defibrillator HeartLogic index has proven to be a sensitive and timely predictor of impending heart failure (HF) decompensation. We evaluated the impact of a standardized follow-up protocol implemented by nursing staff and based on remote management of alerts.
Methods: The algorithm was activated in HF patients at 19 Spanish centers.
Introduction: A new technology capable of monitoring local impedance (LI) and contact force (CF) has recently been developed. At the same time, there is growing concern regarding catheter ablation performed under fluoroscopy guidance, due to its harmful effects for both patients and practitioners. The aim of this study was to assess the safety and effectiveness of zero-fluoroscopy cavotricuspid isthmus (CTI) ablation monitoring LI drop and CF as well as to elucidate if these parameters can predict successful radiofrequency (RF) applications in CTI ablation.
View Article and Find Full Text PDFObjective: To investigate the association of accelerometer-measured lifestyle physical activity with rapid-rate non-sustained ventricular tachycardias (RR-NSVTs) in patients with arrhythmogenic cardiomyopathy (AC).
Methods: This multicentre, observational study enrolled 72 patients with AC, including right, left and biventricular forms of the disease, with underlying desmosomal and non-desmosomal mutations. Lifestyle physical activity, objectively monitored with accelerometers (ie, movement sensors) and RR-NSVT, identified as >188 bpm and >18 beats from a textile Holter ECG for 30 days.