Eliciting information from patients is fundamental to medical professionals' capacity to deliver good healthcare outcomes in Emergency Departments (EDs). There are different kinds of utterances that "do questioning", and health professionals can variously attend to the medical agenda and the interpersonal aspects of their interactions with those attending the ED in the way that they construct these utterances. We investigate a corpus of ED interactions to determine the prevalence and range of utterances produced by doctors and directed at patients that "do questioning.
View Article and Find Full Text PDFWe developed novel zwitterionic near infrared (NIR) fluorescent agents (ABZWCY-HPβCD and AAZWCY-HPβCD), which exhibit favorable hydrophilicity, low plasma protein binding, high stability and non-toxicity. These attractive characteristics ensure that they are excreted rapidly, without any skin accumulation or metabolism . More importantly, zwitterionic HPβCD based agents can be efficiently filtrated by the glomerulus and completely excreted through the kidneys into urine without reabsorption or secretion in the kidney proximal tubule.
View Article and Find Full Text PDFEvaluation of renal function is crucial for a number of clinical situations. Here, we reported a novel exogenous fluorescent marker (FITC-HPβCD) to real-time assess renal function by using a transcutaneous fluorescent detection technique. FITC-HPβCD was designed based on the principle of renal clearance of designed drugs.
View Article and Find Full Text PDFTranscutaneous measurement of the glomerular filtration rate (GFR) is now frequently used in animal studies. GFR allows consecutive measurements on the same animal, including multiple measurements on a daily basis, because no blood sampling is required. Here we derive and validate a novel kinetic model for the description of transcutaneously measured FITC-Sinistrin excretion kinetics.
View Article and Find Full Text PDFStud Health Technol Inform
January 2018
Glomerular filtration rate (GFR) is considered the best parameter for the assessment of renal function, being usually determined on the basis of urine or plasma clearance of exogenous renal markers. The common methodology is invasive, time consuming and cumbersome, with multiple blood and/or urine sampling and following laboratory assays required. The method detailed here allows to transcutaneously determine the renal function in awake animals, in a non-invasive and efficient manner by using an electronic device which detects the fluorescence emitted through the skin from the renal marker FITC-Sinistrin.
View Article and Find Full Text PDF