Publications by authors named "J P Kretzer"

Objectives: Several short-term analyses from German Registry for Acute Aortic Dissection Type A (GERAADA) have been published. This study investigated whether short-term risk factors are transferable to the long-term prognosis of patients.

Methods: Thirty-three centres with 2686 patients participated in the long-term follow-up.

View Article and Find Full Text PDF

Purpose: As capsule elongation is assumed to weaken the static stability of the shoulder joint, the purpose of this biomechanical study was to demonstrate that capsule elongation occurs immediately after a first-time shoulder dislocation and not just after recurrent dislocation events. We hypothesize an increment in joint clearance due to joint capsule elongation after a first-time dislocation.

Methods: An experimental in-vitro study was conducted on 6 paired fresh frozen human shoulders (4 females; 2 males; 12 specimen) with a mean age of 80 (Range 67-89) years.

View Article and Find Full Text PDF

Implant modularity within revision total hip arthroplasty (THA) offers multiple implant configurations and allows surgeons a high intraoperative flexibility to restore functionality to the patients joint, even in complex revision cases. However, a rare but devastating complication for patients, clinicians and manufacturers presenting a breakage of the taper junction between the distal stem and the proximal implant part. Aside from implant and patient specific risk factors, corrosion and fretting at the stem junctions have been associated with taper failure.

View Article and Find Full Text PDF

Background: In this article, an overview and comparison of the most commonly used cemented hip stems, grouped into different stem types and cement mantle thickness, is given to see which combination performs well.

Methodology: Revision rates of cemented stem types were categorized from the Endoprosthesis Register-Germany, and 3‑ and 5‑year revision rates were reported and analyzed. For the research, the focus was on the Exeter, C‑Stem, MS-30, Excia, Bicontact, Charnley, Müller straight stem, Twinsys, Corail, Avenir, Quadra, and the Lubinus SP II stems.

View Article and Find Full Text PDF

Background: To reduce hardware-related complications in coracoid graft fixation to the anterior aspect of the glenoid, a metal-free Latarjet technique was recently introduced. The aim of this study was to compare the primary stability of a classic Latarjet procedure with 2 metal screws to a novel metal-free, all-suture cerclage method. It is hypothesized that fixation of the coracoid graft with 2 malleolar screws will provide higher primary stability compared with an all-suture cerclage technique.

View Article and Find Full Text PDF