We present a very complete database of individual non-methane hydrocarbon (NMHC) measurements with high temporal resolution (hourly) in a rural background atmosphere. We show their use to characterize the biogenic NMHC as well as to identify the transport and impact of anthropogenic NMHC on rural areas. In January 2003 an automatic GC-FID analyzer of volatile organic compounds between 2 and 10 carbon atoms (C2-C10 VOCs) was placed in the centre of the Valderejo Natural Park in northern Iberia (42.
View Article and Find Full Text PDFThis paper presents results of the processing and validation of data collected by an automatic gas chromatograph (AGC). This system was used to monitor 62 volatile organic compounds (VOCs) in urban air in the Basque Country, Spain. The nonpolar compounds (C2-C10) identified-paraffins, olefins, aromatics, and chlorinated compounds-accounted for 88% of the mass of total non-methane hydrocarbons (TNMHCs) in ambient air.
View Article and Find Full Text PDFJ Air Waste Manag Assoc
August 1999
During a preliminary field campaign of volatile organic compound (VOC) measurements carried out in an urban area, two complementary analysis techniques were applied to establish the technical and scientific bases for a strategy to monitor and control VOCs and photochemical oxidants in the Autonomous Community of the Basque Country. Integrated sampling was conducted using Tenax sorbent tubes and laboratory analysis by gas chromatography, and grab sampling and in situ analysis also were conducted using a portable gas chromatograph. With the first technique, monocyclic aromatic hydrocarbons appeared as the compounds with the higher mean concentrations.
View Article and Find Full Text PDF