Publications by authors named "J Jeyasugiththan"

This study assesses radiation doses in cone beam computed tomography (CBCT) procedures in Sri Lanka, with the goal of establishing initial diagnostic reference levels (DRLs). Data from 1162 retrospective scans across four institutions were analyzed, and the medians of the pooled dose distribution for seven clinical indication categories were presented as the DRL values. The proposed DRLs based on clinical indications are 1013 mGy·cm2 for pathological conditions including cysts, tumors, and lesions, 1307 mGy·cm2 for implant planning, 1266 mGy·cm2 for presurgery assessment, and 1585 mGy·cm2 for evaluation of sinus and nasal pathology, temporomandibular disorder, and facial trauma.

View Article and Find Full Text PDF

The introduction of automatic tube current modulation (ATCM) has resulted in complex relationships between scanner parameters, patient body habitus, radiation dose, and image quality. ATCM adjusts tube current based on x-ray attenuation variations in the scan region, and overall patient dose depends on a combination of factors. This work aims to develop mathematical models that predict CT radiation dose and image noise in terms of attenuating diameter and all relevant scanner parameters.

View Article and Find Full Text PDF

This study represents the first national survey conducted in Sri Lanka to establish national diagnostic reference levels (NDRLs) for screening and diagnostic acquisitions in digital mammography (2D-DM) and digital breast tomosynthesis (DBT). Additionally, the study investigated the relationship between average glandular dose (AGD) and compressed breast thickness (CBT) and introduced a novel concept called dose range bands (DRBs) as a tool for optimizing radiation dose in mammography. DICOM metadata was used to extract dose data and exposure parameters from women undergoing either screening (350) or diagnostic (750) DM.

View Article and Find Full Text PDF

In head and neck computed tomography (CT) imaging, the optimisation of radiation dose is crucial due to the presence of radio-sensitive organs. This study aimed to evaluate the radiation dose in multi-slice CT for head and neck examinations. Volume CT dose index, dose length product and effective dose (E) were assessed for 10 head and neck CT scans performed on 292 adult patients (mean age 49.

View Article and Find Full Text PDF

The present survey evaluated the level of awareness of radiological protection concepts and imaging parameters among Sri Lankan radiographers for the first time. The data were collected using an electronic questionnaire of 22 questions on demographic data, awareness of radiation protection concepts and imaging parameters. Only 84 out of 122 (68.