Publications by authors named "J Colsher"

The purpose of this study was to validate a novel approach to estimating effective dose (E) in 'fast-kV switch dual energy computed tomography' using MOSFET detectors. The effective energy of the combined dual energy environment was characterized with the dual energy CT scanner and then MOSFETs were calibrated matching to the effective energy of the dual energy CT beam with a conventional CT beam. The calibration method was then experimentally validated by comparing the dose between MOSFET and an ion chamber (IC) using a standard CTDI body phantom.

View Article and Find Full Text PDF

Purpose: Volume quantifications of lung nodules with multidetector computed tomography (CT) images provide useful information for monitoring nodule developments. The accuracy and precision of the volume quantification, however, can be impacted by imaging and reconstruction parameters. This study aimed to investigate the impact of iterative reconstruction algorithms on the accuracy and precision of volume quantification with dose and slice thickness as additional variables.

View Article and Find Full Text PDF

Objectives: To investigate the impact of an adaptive statistical iterative reconstruction (ASiR) algorithm on diagnostic accuracy and confidence for the diagnosis of hypervascular liver tumours, as well as the reader's perception of image quality, using a low tube voltage (80 kVp), high tube current computed tomography (CT) technique.

Methods: Forty patients (29 men, 11 women) with 65 hypervascular liver tumours underwent dual energy CT. The 80 kV set of the dual energy acquisition was reconstructed with standard filtered backprojection (FBP) and ASiR at different blending levels.

View Article and Find Full Text PDF

Current estimation of lung nodule size typically relies on uni- or bi-dimensional techniques. While new three-dimensional volume estimation techniques using MDCT have improved size estimation of nodules with irregular shapes, the effect of acquisition and reconstruction parameters on accuracy (bias) and precision (variance) of the new techniques has not been fully investigated. To characterize the volume estimation performance dependence on these parameters, an anthropomorphic chest phantom containing synthetic nodules was scanned and reconstructed with protocols across various acquisition and reconstruction parameters.

View Article and Find Full Text PDF

Purpose: To determine the quantitative relationship between image quality and radiologist performance in detecting small lung nodules in pediatric CT.

Methods: The study included clinical chest CT images of 30 pediatric patients (0-16 years) scanned at tube currents of 55-180 mA. Calibrated noise addition software was used to simulate cases at three nominal mA settings: 70, 35, and 17.

View Article and Find Full Text PDF