Cell shape remodeling is a principal driver of epithelial tissue morphogenesis. While progress continues to be made in our understanding of the pathways that control the apical (top) geometry of epithelial cells, we know comparatively little about those that control cell basal (bottom) geometry. To examine this, we used the Drosophila ommatidium, which is the basic visual unit of the compound eye.
View Article and Find Full Text PDFTissue slicing is at the core of many approaches to studying biological structures. Among the modern volume electron microscopy (vEM) methods, array tomography (AT) is based on serial ultramicrotomy, section collection onto solid support, imaging via light and/or scanning electron microscopy, and re-assembly of the serial images into a volume for analysis. While AT largely uses standard EM equipment, it provides several advantages, including long-term preservation of the sample and compatibility with multi-scale and multi-modal imaging.
View Article and Find Full Text PDFInorganic polyphosphate (polyP) is a ubiquitous polymer that controls fundamental processes. To overcome the absence of a genetically tractable mammalian model, we developed an inducible mammalian cell line expressing Escherichia coli polyphosphate kinase 1 (EcPPK1). Inducing EcPPK1 expression prompted polyP synthesis, enabling validation of polyP analytical methods.
View Article and Find Full Text PDFPurpose: To evaluate the safety and intraocular pressure (IOP)-lowering efficacy of 2 models of the travoprost intraocular implant (fast-eluting [FE] and slow-eluting [SE] types) from 1 of 2 phase 3 trials (the GC-010 trial).
Design: Multicenter, randomized, double-masked, sham-controlled, noninferiority trial.
Participants: Patients with open-angle glaucoma or ocular hypertension having an unmedicated baseline mean diurnal IOP (average of 8 am, 10 am, and 4 pm time points) of ≥ 21 mmHg, and IOP of ≤ 36 mmHg at each of the 8 am, 10 am, and 4 pm timepoints at baseline.
Introduction: This prospective, multicenter, randomized, double-masked pivotal phase 3 trial evaluated the efficacy and safety of the travoprost intracameral SE-implant (slow-eluting implant, the intended commercial product) and FE-implant (fast-eluting implant, included primarily for masking purposes) compared to twice-daily (BID) timolol ophthalmic solution, 0.5% in patients with open-angle glaucoma (OAG) or ocular hypertension (OHT).
Methods: The trial enrolled adult patients with OAG or OHT with an unmedicated mean diurnal intraocular pressure (IOP) of ≥ 21 and unmedicated IOP ≤ 36 mmHg at each diurnal timepoint (8 A.