The paper presents a validation of novel multichannel ballistocardiography (BCG) measuring system, enabling heartbeat detection from information about movements during myocardial contraction and dilatation of arteries due to blood expulsion. The proposed methology includes novel sensory system and signal processing procedure based on Wavelet transform and Hilbert transform. Because there are no existing recommendations for BCG sensor placement, the study focuses on investigation of BCG signal quality measured from eight different locations within the subject's body.
View Article and Find Full Text PDFThis paper introduces a novel algorithm for effective and accurate extraction of non-invasive fetal electrocardiogram (NI-fECG). In NI-fECG based monitoring, the useful signal is measured along with other signals generated by the pregnant women's body, especially maternal electrocardiogram (mECG). These signals are more distinct in magnitude and overlap in time and frequency domains, making the fECG extraction extremely challenging.
View Article and Find Full Text PDFIEEE J Biomed Health Inform
June 2022
This pilot comparative study evaluates the usability of the alternative approaches to magnetic resonance (MR) cardiac triggering based on ballistocardiography (BCG): fiber-optic sensor (O-BCG) and pneumatic sensor (P-BCG). The comparison includes both the objective and subjective assessment of the proposed sensors in comparison with a gold standard of ECG-based triggering. The objective evaluation included several image quality assessment (IQA) parameters, whereas the subjective analysis was performed by 10 experts rating the diagnostic quality (scale 1 - 3, 1 corresponding to the best image quality and 3 the worst one).
View Article and Find Full Text PDFSynchronization of human vital signs, namely the cardiac cycle and respiratory excursions, is necessary during magnetic resonance imaging of the cardiovascular system and the abdominal cavity to achieve optimal image quality with minimized artifacts. This review summarizes techniques currently available in clinical practice, as well as methods under development, outlines the benefits and disadvantages of each approach, and offers some unique solutions for consideration.
View Article and Find Full Text PDFThis study focuses on the design of a measuring system for monitoring the power quality within the SMART street lighting test polygon at university campuses with relation to testing an adaptive current control strategy for three-phase shunt active power filters. Unlike conventional street lighting, SMART elements are powered 24/7. Due to the electronic character of the power part of such mass appliances, there are increased problems with the power quality of the electric energy.
View Article and Find Full Text PDF