Percutaneous Coronary Intervention (PCI) is a treatment method that involves reopening narrowed arteries with a balloon catheter that delivers a cylindrical, mesh-shaped implant device to the site of the stenosis. Currently, by applying a coating to a bare metal stent (BMS) surface to improve biocompatibility, the main risks after PCI, such as restenosis and thrombosis, are reduced while maintaining the basic requirements for the mechanical behavior of the stent itself. In this work, for the first time, the development and optimization process of the spatial structure of the Co-Cr stent (L-605) with a graphene-based coating using cold-wall chemical vapor deposition (CW-CVD) to ensure uniform coverage of the implant was attempted.
View Article and Find Full Text PDF: With modern diagnostic tools, incidence ischemia with no obstructive coronary atherosclerosis (INOCA) and heart failure with preserved ejection fraction (HFpEF) are found to be much higher than previously believed, and-as they lead to adverse cardiovascular outcomes-their causes and development are subjects of ongoing research. There is growing evidence that coronary microvascular dysfunction might be the underlying cause of both INOCA and HFpEF. : In 65 patients with effort angina but no obstructive coronary artery disease, the index of microvascular resistance and coronary flow reserve were measured invasively in the LAD.
View Article and Find Full Text PDFThe immune responses to both SARS-CoV-2 infection and vaccines are of key importance in prevention efforts. In April and May 2020, 703 study participants tested for COVID-19 by PCR tests were registered. In June and July 2020, they were examined for the presence of SARS-CoV-2 S1/S2 IgG.
View Article and Find Full Text PDFThe registration of physical signals has long been an important part of cardiological diagnostics. Current technology makes it possible to send large amounts of data to remote locations. Solutions that enable diagnosis and treatment without direct contact with patients are of enormous value, especially during the COVID-19 outbreak, as the elderly require special protection.
View Article and Find Full Text PDFGraphene coating on the cobalt-chromium alloy was optimized and successfully carried out by a cold-wall chemical vapor deposition (CW-CVD) method. A uniform layer of graphene for a large area of the Co-Cr alloy (discs of 10 mm diameter) was confirmed by Raman mapping coated area and analyzing specific G and 2D bands; in particular, the intensity ratio and the number of layers were calculated. The effect of the CW-CVD process on the microstructure and the morphology of the Co-Cr surface was investigated by scanning X-ray photoelectron microscope (SPEM), atomic force microscopy (AFM), scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDS).
View Article and Find Full Text PDF