The Response Time Concealed Information Test can reveal that a person recognizes a relevant item (probe, e.g., a murder weapon) among other, irrelevant items (controls), based on slower responses to the probe compared to the controls.
View Article and Find Full Text PDFBackground: Repeated action or inaction toward objects changes preferences for those objects. However, it remains unclear whether such training activates approach-avoidance motivation toward the objects, which leads to actual behavior. We conducted a pre-registered online experiment to examine whether approach and avoidance tendencies were affected by the experience of having executed or withheld a button-press response to a stimulus.
View Article and Find Full Text PDFBackground: Heterozygous loss-of-function mutations in the chromodomain helicase DNA-binding protein 7 (CHD7) gene cause CHARGE syndrome characterized by various congenital anomalies. A majority of patients with CHARGE syndrome present with congenital hypogonadotropic hypogonadism (HH), and combined pituitary hormone deficiency (CPHD) can also be present. Whereas CHD7 mutations have been identified in some patients with isolated HH without a diagnosis of CHARGE syndrome, it remains unclear whether CHD7 mutations can be identified in patients with CPHD who do not fulfill the criteria for CHARGE syndrome.
View Article and Find Full Text PDFExogenous insulin can induce insulin antibodies that have a low affinity/high binding capacity. Similar to what is observed in insulin autoimmune syndrome, these insulin antibodies can cause fasting hypoglycemia and postprandial hyperglycemia, a phenomenon known as "exogenous insulin antibody syndrome" (EIAS). Cases of EIAS in patients with type 1 and type 2 diabetes have been sporadically reported, mainly in Asia.
View Article and Find Full Text PDFPrevious studies have posited that the significance of a crime-relevant item in a question produces differential physiological responses in the Concealed Information Test (CIT). However, this term is equivocal and needs to be clarified in order to strengthen the theoretical underpinnings of the CIT. The present study examined the hypothesis that differential responding depends on the examinee's understanding of which item in a question is relevant to a given context.
View Article and Find Full Text PDFThe display duration of stimuli is overestimated due to the increase in phasic arousal induced by the stimuli or high levels of background arousal. A previous study demonstrated that display duration of items (2 s) was overestimated when a participant attempted to conceal one of the items so as not to be detected in the concealed information test (CIT). As the time perception remained the same between the item to be concealed and the other items, the overestimation was thought to be due to the high level of background arousal under the conceal condition.
View Article and Find Full Text PDFThe orienting response (OR) account of the Concealed Information Test (CIT) posits that physiological responses to CIT items are components of the OR. Physiological variations within a stimulus sequence were investigated in an OR task (Study 1) and the CIT (Study 2). In Study 1, an unexpected increase in tone intensity was introduced after repeated standard tone presentations.
View Article and Find Full Text PDFThe item to be concealed elicits greater physiological arousal than other items. Since high physiological arousal causes an overestimation of time, the display duration of an item is expected to be perceived as longer when people intend to conceal it. After stealing and concealing one item, 36 university students were asked to judge the display duration of an item as shorter than, equal to, or longer than a memorised duration of 2 s.
View Article and Find Full Text PDFJapan is the only country where the polygraph with the concealed information test (CIT) is widely applied to criminal investigations. The CIT can reveal whether an examinee has knowledge of specific details of a crime. Furthermore, the CIT can extract crime-relevant information that investigative organizations have not yet uncovered.
View Article and Find Full Text PDFRecent studies have shown that a memorized item in the Concealed Information Test elicits a frontal negative slow wave (500-1000 ms) of the event-related potential, the cortical source of which involves the right prefrontal cortex. To examine whether this negative slow wave reflects a process that is specific to concealment rather than a more general cognitive control process, we compared the event-related potentials of 24 participants in four conditions involving the presence or absence of memory and the intention to conceal. Results showed that right prefrontal activation during the frontal negative slow wave (estimated by Standardized Low Resolution Brain Electromagnetic Tomography) was only observed when participants attempted to conceal the memorized item, but not when they were motivated to reveal it or had no intention to conceal.
View Article and Find Full Text PDFThe concealed information test (CIT) is a psychophysiological memory detection technique for examining whether an examinee recognizes crime-relevant information. In current statistical analysis practice, the autonomic responses are usually transformed into Z scores within individuals to remove inter- and intra-individual variability. However, this conventional procedure leads to overestimation of the effect size, specifically the standardized mean difference of the autonomic responses between the crime-relevant information and the crime-irrelevant information.
View Article and Find Full Text PDFRecent studies on deception have shown that a late positive potential (LPP), a component of event-related brain potentials, is elicited when a participant wishes to conceal recognition of the eliciting stimulus. The LPP occurs about 500 ms after stimulus onset and has an occipital scalp distribution with concurrent negativity at frontal sites. The present study investigated the cortical sources of the LPP associated with the intention to conceal.
View Article and Find Full Text PDFPalmatier and Rovner (2015) discussed the possible interplay of two major methods of polygraph examination, the Comparison Question Test (CQT) and the Concealed Information Test (CIT). In this comment, we argue that such an attempt overlooks fundamental differences between the two methods. Specifically, both methods differ in their criterion variables; detecting deception versus detecting memory traces.
View Article and Find Full Text PDFThe concealed information test (CIT) can be used to assess whether an individual possesses crime-related information. However, its discrimination performance has room for improvement. We examined whether screening out participants who do not respond distinctively on a pretest improves the diagnosticity of a mock-crime CIT.
View Article and Find Full Text PDFMany studies on the Concealed Information Test have focused on phasic physiological changes that are temporally locked to stimulus presentation. However, little is known about changes in tonic, basal physiological levels throughout a stimulus series. This study focused on changes in tonic physiological activities during the CIT.
View Article and Find Full Text PDFClin Neurophysiol
February 2015
Objective: The interaction between affective and cognitive processes has been examined using the late positive potential (LPP) component of the event-related brain potential. The LPP is elicited not only by affective stimuli but also by nonaffective stimuli that require effortful cognitive processing. However, it is unclear whether these LPPs are equivalent.
View Article and Find Full Text PDFThe concealed information test (CIT) assesses an examinee's recognition of a crime-relevant item using physiological measures. However, a guilty examinee not only recognizes the crime-relevant item but also conceals the recognition intentionally. In this study, we attempted to identify the effect of concealing the recognition on event-related potentials and autonomic responses.
View Article and Find Full Text PDFPsychophysiological detection of deception has seen increased attention in both research and applied settings. In this field, the most scientifically validated paradigm is the Concealed Information Test (CIT). The CIT does not directly deal with whether a participant is lying, but examines whether a participant recognizes a critical relevant detail, inferred by differences in physiological responses between critical and non-critical items.
View Article and Find Full Text PDFFront Psychol
December 2012
The Concealed Information Test (CIT) is a psychophysiological technique for examining whether a person has knowledge of crime-relevant information. Many laboratory studies have shown that the CIT has good scientific validity. However, the CIT has seldom been used for actual criminal investigations.
View Article and Find Full Text PDFThe concealed information test (CIT) assesses an examinee's crime-relevant memory on the basis of physiological differences between crime-relevant and irrelevant items. The CIT based on autonomic measures has been used for criminal investigations, while the CIT based on event-related potentials (ERPs) has been suggested as a useful alternative. To combine these two methods, we developed a quantification method of ERPs measured in the autonomic-based CIT where each item was repeated only 5 times.
View Article and Find Full Text PDFInt J Psychophysiol
August 2011
The Concealed Information Test (CIT) assesses an examinee's knowledge about a crime based on response differences between crime-relevant and crime-irrelevant items. One effective measure in the CIT is the respiration line length, which is the average of the moving distances of the respiration curve in a specified time interval after the item onset. However, the moving distance differs between parts of a respiratory cycle.
View Article and Find Full Text PDFThe concealed information test (CIT) has been used to detect information that examinees possess by means of their autonomic responses. However, the central activities related to these autonomic responses remain unclear. In this study, we simultaneously recorded 128-ch event-related potentials (ERPs) and various autonomic responses (heart rate, respiratory rate, respiratory amplitude, cutaneous blood flow, and skin conductance response) to a critical item (i.
View Article and Find Full Text PDFWhether an examinee has information about a crime is determined by the Concealed Information Test based on autonomic differences between the crime-related item and other control items. Multivariate quantitative statistical methods have been proposed for this determination. However, these require specific databases of responses, which are problematic for field application.
View Article and Find Full Text PDFThis study examined effects of arousal level on the physiological responses in a polygraph examination using the Concealed Information Test (CIT). Thirty-nine healthy college students were tested with or without evaluative observation. Electrodermal activity, blood pressure, heart rate, normalized pulse volume, and respiration were recorded.
View Article and Find Full Text PDFA latent class discrimination method is proposed for analyzing autonomic responses on the concealed information test. Because there are significant individual differences in autonomic responses, individual response patterns are estimated on the pretest. Then an appropriate discriminant formula for the response pattern of each individual is applied to the CIT test results.
View Article and Find Full Text PDF