Purpose: To assess the clinical outcome of the involved-node radiotherapy (INRT) concept using modern radiation treatments (intensity-modulated radiotherapy [IMRT] or deep-inspiration breath-hold radiotherapy [DIBH) in patients with localized supradiaphragmatic Hodgkin lymphoma.
Methods And Materials: All but 2 patients had early-stage Hodgkin lymphoma, and they were treated with chemotherapy prior to irradiation. Radiation treatments were delivered using the INRT concept according to European Organization for Research and Treatment of Cancer guidelines.
Purpose: To compare the dose distribution between three-dimensional conformal radiotherapy (3DCRT), intensity modulated radiotherapy (IMRT) with six coplanar beams (6b-IMRT) and IMRT with nine coplanar beams (9b-IMRT) during adjuvant radiotherapy for retroperitoneal sarcoma.
Methods And Materials: The 10 most recent patients who had received adjuvant radiotherapy were reviewed. Three different treatment plans were generated (3DCRT, 6b-IMRT and 9b-IMRT) to deliver 50.
Background And Purpose: To evaluate the input of FDG-PET data in the implementation of the involved-node radiotherapy concept and dose painting.
Materials And Methods: Patients with early-stage Hodgkin lymphoma treated with combined modality treatments. First, patients underwent a PET/CT before chemotherapy in the treatment position using a head and shoulder immobilization mask.
Background And Purpose: In the framework of an ESTRO ESQUIRE project, the BRAPHYQS Physics Network and the EQUAL-ESTRO laboratory have developed a procedure for checking the absorbed dose to water in the vicinity of HDR or PDR sources using a mailed TLD system. The methodology and the materials used in the procedure are based on the existing EQUAL-ESTRO external radiotherapy dose checks.
Materials And Methods: A phantom for TLD postal dose assurance service, adapted to accept catheters from different HDR afterloaders, has been developed.
Background And Purpose: A new phantom is proposed for measuring the strength of 192Ir high dose rate sources and for verification of the dose calculated by the treatment planning system. The complete formalism and measurement procedure for this phantom is described, as well as the preliminary results obtained in a number of centers around Brazil.
Materials And Methods: The measurements are performed using powder thermoluminescent dosimeter capsules; the source strength is measured in air and the verification of the dose calculation algorithm in water phantom.
Background And Purpose: A geometric check procedure of the reconstruction techniques used in brachytherapy treatment planning systems was developed by the EQUAL (European Quality Laboratory) Laboratory in the framework of the ESTRO's (European Society for Therapeutic Radiology and Oncology) project 'ESQUIRE' (Education Science and QUality assurance In Radiotherapy in Europe [Baumann M, Brada M. Towards equity in turbulent Europe ESTRO, European cooperation and the European Commission. Radiother Oncol 2005;75:251-2.
View Article and Find Full Text PDFBackground And Purpose: An anthropomorphic water filled polymethylmethacrylate (PMMA) phantom designed to serve as a Quality Assurance (QA) tool and a training aid in brachytherapy of gynaecological tumours is investigated and presented. Several dosimetric parameters associated with the dose rate calculation can be verified with the aid of this phantom such as the source positioning, its imaging reconstruction from radiographs and the accuracy of the algorithm used for manual or computer dose rate calculation.
Material And Methods: The phantom walls and the internal structure are 5mm thick and consist of PMMA, in the form of the abdomen taken from a female Alderson Phantom Marker points representing the organs of interest were determined from computed tomography scans of a patient of similar size.