Objective: This study reviewed the application of curved and bileaflet designs to pulmonary expanded polytetrafluoroethylene conduits with diameters of 10 to 16 mm and characterized this conduit on in vitro experiment, including particle image velocimetry.
Methods: All patients who received this conduit between 2010 and 2022 were evaluated. Three 16-mm conduits were tested in a circulatory simulator at different cardiac outputs (1.
The high-speed liquid-jet velocity achieved using an injector strongly depends on the piston motion, physical property of the liquid, and container shape of the injector. Herein, we investigate the liquid ejection mechanism and a technique for estimating the ejection velocity of a high-speed liquid jet using a pyro jet injector (PJI). We apply a two-dimensional numerical simulation with an axisymmetric approximation using the commercial software ANSYS/FLUENT.
View Article and Find Full Text PDFAnn N Y Acad Sci
September 2006
The cryogenic fluid transfer technique will prove useful for flexible and low-cost space activities by prolonging the life cycle of satellites, orbital transfer vehicles, and orbital telescopes that employ cryogenic fluids, such as reactants, coolants, and propellants. Although NASA has conducted extensive research on this technique to date, a complicated mechanism is required to control the pressure in the receiver tank and avoid a large liquid loss by vaporization. We have proposed a novel fluid transfer method by using swirl flow combined with vapor condensation facilitated by spray cooling.
View Article and Find Full Text PDF