Publications by authors named "Isao Yamaguchi"

[Purpose] We aimed to develop a noninvasive specific ultrasonographic assessment of the talonavicular joint during loading to facilitate the analysis of treatment of flatfoot. [Participants and Methods] Sixty healthy participants underwent ultrasound imaging of the talonavicular joint while sitting and standing. The talonavicular angle was defined as the intersection of the line connecting the navicular and talar heads and the line connecting the talar head and sustentaculum tali.

View Article and Find Full Text PDF

Background: The flexion adduction internal rotation (FADIR) test is performed by the combined motions of hip flexion (with knee flexion), adduction, and internal rotation, and can often reproduce anterior hip pain consistent with an individual's presenting pain. Since it has high sensitivity for intraarticular pathology diagnosis but low specificity, understanding the extraarticular pathology that can induce anterior hip pain in the FADIR test may also be essential. This study hypothesized that the interrelationships between the joint capsule and gluteus minimus differ in individuals with and without FADIR-positive pain and aimed to elucidate the in vivo interrelationships at hip internal rotation in 90°-flexion, which is also often restricted in individuals with FADIR-positive pain.

View Article and Find Full Text PDF

Tetraphenylethene derivatives (TPEs) are used as luminescence probes for the detection of metal ions and biomolecules. These sensors function by monitoring the increase in the photoluminescence (PL) intensity of the TPEs resulting from aggregation-induced emission (AIE) upon interaction with the analytes. The AIE behavior of the sensors was investigated by measuring their PL.

View Article and Find Full Text PDF

Peripheral nerve tension is known to be related to the pathophysiology of neuropathy; however, assessing this tension is difficult in a clinical setting. In this study, we aimed to develop a deep learning algorithm for the automatic assessment of tibial nerve tension using B-mode ultrasound imaging. To develop the algorithm, we used 204 ultrasound images of the tibial nerve in three positions: the maximum dorsiflexion position and -10° and -20° plantar flexion from maximum dorsiflexion.

View Article and Find Full Text PDF

Although the flexion abduction external rotation (FABER) test is a useful hip provocation test, hip soft tissue characteristics in the FABER position remain unclear. This study investigated the in-vivo joint capsule characteristics, including its articular cavity area and relation to the fat pad surrounded by the joint capsule and pericapsular muscles, in the FABER position using magnetic resonance imaging. Thirteen hips from 13 healthy volunteers were analyzed.

View Article and Find Full Text PDF

Purpose: This study aimed at analyzing the relationship between the estimated volume of distribution on computed tomography (eVd) of non-ionic contrast medium and four different patients' body size parameters (BSPs) (total body weight, body mass index, body surface area, and lean body weight) in abdominal dynamic contrast-enhanced computed tomography (ADCE-CT) . Moreover, this study intended to derive a method for calculating the iodine dose to target contrast enhancement.

Methods: We measured enhanced CT values of the equilibrium phase of the abdominal aorta in 527 patients who underwent ADCE-CT.

View Article and Find Full Text PDF

Water-soluble cationic and anionic oligofluorenes bearing N1-alkylcytosine side chains, namely OF-1 and OF-2, were synthesized. The photoluminescence (PL) intensity of an aqueous solution of OF-1 decreased on the addition of (TTAGGG)m as telomere DNA models. In contrast, the PL intensity of OF-2 increased on the addition of DNA.

View Article and Find Full Text PDF

Reaction of -(2,4-dinitrophenyl)pyridinium chloride (salt(Cl)) with sodium dicyanamide (Na(CN)N) resulted in anion exchange between Cl and (CN)N to yield a new Zincke salt, salt((CN)N). Reactions of salt((CN)N) with piperazine, specifically ()-(-)- or ()-(+)-2-methylpiperazine under eco-friendly conditions, such as in aqueous solution, in the absence of a catalyst, and at room temperature, resulted in pyridinium ring opening to yield ionic high-molecular-weight polymers with 5-2,4-dienylideneammonium dicyanamide units or chiral 5-(2-methylpiperazinium)-2,4-dienylideneammonium dicyanamide units, namely, polymer(H;(CN)N), polymer(-Me;(CN)N), and polymer(-Me;(CN)N). UV-Vis measurements revealed that the π-conjugation system expanded along the polymer chain due to the orbital interaction between the electrons on the two nitrogen atoms of the piperazinium ring.

View Article and Find Full Text PDF

For improvement of three-dimensional time-of-flight magnetic resonance angiography (3D-TOF-MRA) image quality in the neck, fat-subtracted MRA by use of the two-point Dixon technique was compared with conventional fat-suppressed MRA techniques. Three different types of neck 3D-TOF-MRA were obtained [minimum echo time (TE) (1.9 ms), opposed-phase TE (3.

View Article and Find Full Text PDF

The purpose of this study was to verify the applicability of measurement of slice thickness of magnetic resonance imaging (MRI) by the delta method, and to discuss the measurement precision by the disk diameter and baseline setup of the slice profile of the delta method. The delta method used the phantom which put in the disk made of acrylic plastic. The delta method measured the full width at half maximum (FWHM) and the full width at tenth maximum (FWTM) from the slice profile of the disk signal.

View Article and Find Full Text PDF

Object: To propose a new arterial spin labeling (ASL) perfusion-imaging method (alternate slab width inversion recovery ASL: AIRASL) that takes advantage of the qualities of 3.0 T.

Materials And Methods: AIRASL utilizes alternate slab width IR pulses for labeling blood to obtain a higher signal-to-noise ratio (SNR).

View Article and Find Full Text PDF

Our aim in this study was to determine an optimal delay time of hepatic arterial phase (HAP) imaging of hypervascular hepatocellular carcinomas (HCCs) in dynamic contrast-enhanced MDCT (DCE-CT) by use of the bolus-tracking method. The time-enhancement curves (TECs) of the aorta and the contrast of the hepatic arterial and portal system (APC) in the pharmacokinetic analysis were calculated. The clinical study included 41 patients with known or suspected HCC who underwent DCE-CT.

View Article and Find Full Text PDF

A magnetic resonance imaging (MRI) system compatible linear stage was developed. The stage was made of acrylic plastic and moving power was applied by an ultrasonic motor. Moving distance of the stage was detected by counting the number of motor rotations using a optic fiber sensor.

View Article and Find Full Text PDF

Application of microTAS (micro Total Analysis Systems) technologies utilizing chips with microfluidic channels to clinical diagnostic testing has drawn a lot of attention since it is expected to contribute to shortening reaction time, reduction of reagent/sample consumption, reducing instrument size, and other advantages of microchip electrophoresis. We have developed a fully automated immunoassay system by employing isotachophoresis followed by capillary gel electrophoresis for immunoreaction and B/F separation in microfluidic channels on polymer microchips. Laser-Induced Fluorescence (LIF) was used for detection of the sandwich immunocomplex composed of DNA-conjugate antibody, antigen and fluorescent dye-conjugated antibody.

View Article and Find Full Text PDF

Bone char (BC) was prepared by carbonizing four types of animal biomass, and the adsorption of fluoride ions and elution of phosphate ions were investigated. It was found that the BC yield decreased as carbonization temperature increased, and that carbonization temperature had no significant effect on surface pH, base or acid consumptions. Fluoride ion adsorption was increased in BC produced at a low carbonization temperature.

View Article and Find Full Text PDF

The present study investigates (1) ozone treatment, (2) adsorption treatment using activated carbon treatment, and (3) ozone treatment with activated carbon for their efficacy in removing 17beta-estradiol (E2) present in an aqueous solution. Both ozone and activated carbon treatments for 20 min were effective in removing E2 (initial concentration, 100 mg/L). However, both treatments have been used for two processes, and the disposal time with these treatments is more than that of another treatment.

View Article and Find Full Text PDF

Implementation of the on-chip immunoassay for alpha-fetoprotein (AFP)-L3% was achieved using a fully automated microfluidic instrument platform that will prepare the chip and run the assay with a total assay time of less than 10min. Reagent/sample mixing, concentration, and reaction in microfluidic channels occur by the electrokinetic analyte transport assay (EATA) technique, enabling the integration of all assay steps on-chip. The determination of AFP-L3%, a biomarker for hepatocellular carcinoma, was achieved by the presence of Lens culinaris agglutinin in the separation channel, causing separation of the fucosylated isoform, AFP-L3, from the nonfucosylated AFP-L1 by lectin affinity electrophoresis.

View Article and Find Full Text PDF

The purpose of this study was to suppress CSF flow artifacts in the fast FLAIR sequence at 3.0T MRI. We investigated the influence of thickness of the inversion pulse in the sequence on the high-intensity CSF flow artifacts based on the flow phantom and in-vivo studies at 1.

View Article and Find Full Text PDF

The present study was performed to find the required volume of physiological saline for flushing that will allow the most efficient use of contrast medium during the early phase of dynamic CT. We calculated contrast medium aortic arrival time (AT), time to peak aortic enhancement (TPAE) and the elapsed time to TPAE from AT (rise time) from the TECs of pharmacokinetic analysis and clinical study. The rise time determined in the clinical study was 6.

View Article and Find Full Text PDF

Purpose: The present study was performed to identify the theoretical background for optimal use of the bolus tracking system by analyzing the changes in the initial slope of the aortic time-enhancement curve (TEC).

Materials And Methods: We calculated the contrast medium aortic arrival time (TAR), the time to reach the trigger threshold (effective TAR), the slope of the linear equation of the enhancement unit (enhancement rate), and the time to peak aortic enhancement from the TECs of the pharmacokinetic analysis and retrospective clinical study.

Results: In the pharmacokinetic analysis, the enhancement rate-simulated under conditions of injection duration 30 s and iodine load per body weight 500 mg/kg-was 27.

View Article and Find Full Text PDF

To prevent formation of trihalomethanes (THMs) in drinking water, removing precursors of trihalomethanes (PTHMs) in water resources for tap water is essential. We compared the following three treatments for removal of PTHMs: activated carbon (AC), ozone (OZ) and ozone-activated carbon combination (OZAC). Orange II (OR, an acidic dye), methylene blue (MB, a basic dye) and humic acid (HA) were used as PTHMs.

View Article and Find Full Text PDF

Background: Des-gamma-carboxy prothrombin (DCP), Lens culinaris agglutinin-reactive alpha-fetoprotein ratio (AFP-L3) and total alpha-fetoprotein (AFP) are tumor markers useful for diagnosing and determining the prognosis of hepatocellular carcinoma (HCC). There is a real need for measurement of these three markers on a one-assay platform.

Methods: A method of DCP measurement in human serum was developed using liquid binding assay (LBA), which enables rapid antigen-antibody reaction and bound/free separation on the LiBASys clinical analyzer.

View Article and Find Full Text PDF

The purpose of this study was to decrease vascular artifacts caused by the in-flow effect in three-dimensional inversion recovery prepared fast spoiled gradient recalled acquisition in the steady state (3D IR FSPGR) at 3.0 Tesla. We developed 3D double IR FSPGR and investigated the signal characteristics of the new sequence.

View Article and Find Full Text PDF