Publications by authors named "Isabella Baur"

Polypseudophakia, the concept of using a second intraocular lens (IOL) to supplement an IOL that has already been placed in the capsular bag, was first used as a corrective measure where the power requirement was higher than that of available single IOLs. Subsequently, the technique was modified to compensate for post-operative residual refractive errors. In these early cases, an IOL designed for the capsular bag would be implanted in the sulcus.

View Article and Find Full Text PDF

A variety of situations can lead to the need for an alternative method of intraocular lens (IOL) fixation if implantation in the capsular bag is not possible. Depending on the situation, sulcus-fixated IOLs, iris-fixated IOLs (IFIOLs) and scleral-fixated IOLs (SFIOLs) are available. With SFIOLs, a distinction is made between suture-fixated and sutureless-fixated techniques.

View Article and Find Full Text PDF
Article Synopsis
  • Technical advancements in lens surgery have greatly improved safety and outcomes, expanding indications for refractive lens exchange (RLE).
  • Modern presbyopia-correcting intraocular lenses (IOLs) can effectively restore both distance and near vision, making hyperopic patients ideal candidates for RLE.
  • Careful planning, patient selection, and counseling are essential to address risks and complications, especially in myopic patients who face higher risks like retinal detachment.
View Article and Find Full Text PDF

Purpose: To evaluate visual outcomes and patient-reported results after bilateral femtosecond-laser-assisted refractive lens exchange (RLE) with the implantation of a diffractive trifocal intraocular lens.

Design: Prospective interventional case series.

Methods: A study of 27 patients (54 eyes) implanted with the Clareon PanOptix (Alcon) multifocal intraocular lens during femtosecond-laser-assisted RLE in a university hospital setting.

View Article and Find Full Text PDF

Cataract is among the leading causes of visual impairment worldwide. Innovations in treatment have drastically improved patient outcomes, but to be properly implemented, it is necessary to have the right diagnostic tools. This review explores the cataract grading systems developed by researchers in recent decades and provides insight into both merits and limitations.

View Article and Find Full Text PDF

Purpose: In intraocular lens (IOL) implantation, insertion of the IOL injector enlarges the clear corneal incision. A larger incision size (IS) is associated with a higher risk for surgically induced astigmatism and endophthalmitis. The goal of this study was to determine which parameters most influence the final IS.

View Article and Find Full Text PDF

Purpose: To compare the optical quality and higher order aberrations of four different refractive extended depth of focus intraocular lens (EDOF IOL) models (Lentis Comfort [Teleon Surgical BV], MiniWell (SIFI), LuxSmart [Bausch & Lomb], and AcrySof IQ Vivity [Alcon Laboratories, Inc]) and a monofocal IOL (Tecnis ZCB00; Johnson & Johnson Surgical Vision, Inc).

Methods: An optical metrology instrument (OptiSpheric IOL PRO2; Trioptics GmbH) was used to study image quality metrics of the different IOLs. The modulation transfer function (MTF) was measured at pupil sizes 1 to 5 mm in 1-mm steps.

View Article and Find Full Text PDF

Purpose: We evaluated implantation behavior and injector damage of two different IOL injector systems, the Multisert and the AutonoMe.

Design: Prospective, randomized, comparative study with laboratory investigation.

Methods: We examined used injectors from 48 bilateral cataract cases and assessed video recordings of each Implantation.

View Article and Find Full Text PDF

Cataract surgery can lead to inflammatory processes in the retina due to its invasive nature, resulting in prolonged recovery times and reduced functional outcomes. The aim of the current study is to explore the impact that phacoemulsification parameters have on macular thickness following surgery. This prospective single-center study enrolled 46 healthy patients (46 eyes) who underwent uneventful cataract surgery.

View Article and Find Full Text PDF

This study compared the optical quality and chromatic performance of refractive-diffractive intraocular lenses (IOLs) that are designed to extend the range of vision of pseudophakic patients and alter chromatic aberration. Five IOLs were evaluated, Tecnis Synergy and Triumf POD L GF, both intended to compensate for eye's chromatism, as well as Acriva Trinova Pro C-a lens that increases chromatic aberration, and AT Lisa Tri and AcrySof IQ PanOptix. An optical setup composed of a corneal model inducing monochromatic and chromatic aberrations and incorporating various spectral conditions was employed.

View Article and Find Full Text PDF

Purpose: To evaluate the long-term rotational stability of capsular bag-fixated toric intraocular lenses (IOLs) in polypseudophakic eyes of patients who underwent duet procedure for reversible trifocality.

Design: Retrospective interventional case series.

Methods: We included 34 eyes of 20 patients who underwent duet procedure with implantation of a monofocal toric IOL (RayOne toric, Hoya XY1AT, or a Tecnis ZCT800) into the capsular bag and a trifocal-diffractive Sulcoflex IOL into the ciliary sulcus.

View Article and Find Full Text PDF

Purpose: To study the distribution of spherical aberration (SA) in astigmatic corneas in a cataract population and the relationship between magnitude of corneal astigmatism and fourth-order corneal SA.

Methods: Data routinely collected using a Scheimpflug camera (Pentacam; Oculus Optikgeräte GmbH) were retrospectively analyzed. Patients with a minimum age of 60 years were included.

View Article and Find Full Text PDF

Background: Due to its invasive nature, cataract surgery can lead to inflammatory processes in the posterior segment, which can result in prolonged recovery times, reduced functional outcomes, and late-onset complications. The aim of the current study was to identify wherever phacoemulsification parameters play a role in choroidal thickness change following cataract surgery.

Methods: This prospective single-center study enrolled 31 patients (31 eyes) scheduled to undergo routine cataract surgery.

View Article and Find Full Text PDF

(1) Background: Laparoscopic resection for colon and rectal cancer was introduced in the early 1990s; the aim of this analysis was to show possible advantages of minimal-invasive approaches in rectal cancer surgery. (2) Methods: From 2016 to 2020, all patients undergoing open, laparoscopic or robotic-assisted rectal cancer surgery in Germany were retrospectively analyzed regarding sex distribution, conversion rates and in-hospital mortality rates according to nationwide hospital billing data based on diagnosis-related groups (DRGs). (3) Results: In total, 68,112 patients were analyzed, and most commonly, low anterior rectal resections with primary anastomosis ( = 25,824) were performed with an increase of minimal-invasive procedures over the years (open: 51% to 27%; laparoscopic: 47% to 63% and robotic: 2% to 10%).

View Article and Find Full Text PDF

Early (< 3 months) intraocular lens (IOL) dislocation occurs due to insufficient fixation in the capsular bag, while late dislocation (≥ 3 months) is due to increasing insufficiency of the zonular apparatus. Iris-fixated IOL (IFIOL) and suture- or sutureless-fixated scleral IOL (SFIOL) are currently the most commonly used methods when IOL exchange is indicated. Different methods of scleral fixation with or without sutures have been described.

View Article and Find Full Text PDF

Purpose: To clinically evaluate a diffractive continuous-range-of-vision intraocular lens (IOL) that combines bifocal and extended depth-of-focus technologies in refractive lens exchange (RLE) patients.

Setting: University eye clinic.

Design: Prospective interventional clinical study.

View Article and Find Full Text PDF

Simultaneous implantation of a monofocal or monofocal toric intraocular lens (IOL) into the capsular bag and a multifocal IOL into the ciliary sulcus, referred to as duet procedure, allows us to create multifocality that is more easily reversible than the implantation of a capsular bag-fixated multifocal IOL. The optical quality and results after the duet procedure are equivalent to those of a capsular bag-fixated multifocal IOL. Patients who cannot tolerate the side effects of multifocal optics or who develop an ocular condition leading to loss of function such as age-related macular degeneration (AMD) or glaucoma in the course of their lives may benefit from the reversibility of the procedure.

View Article and Find Full Text PDF

We evaluated the optical quality of two approaches to trifocality: polypseudophakia versus monopseudophakia. The combination (polypseudophakia) of a monofocal Basis Z B1AWY0 and AddOn Trifocal A4DW0M intraocular lens (IOL) was compared to using one Basis Z Trifocal B1EWYN IOL, all from 1stQ GmbH. In both approaches, we measured modulation transfer function (MTF) and Strehl Ratio (SR) values at 3.

View Article and Find Full Text PDF

Presbyopia correction through implantation of a trifocal intraocular lens (IOL) is a modality offered to both cataract and refractive-lens exchange patients. To maximize postoperative satisfaction, IOL selection needs to be made based on patients' requirements aligned with the available technology. Five Trifocal IOLs were assessed in this study, and their differentiating features were identified: Triumf POD L GF, AT Lisa Tri, Tecnis Synergy, AcrySof IQ PanOptix, and Acriva Trinova Pro C.

View Article and Find Full Text PDF

Purpose: Evaluation of reading performance with a novel presbyopia correcting intraocular lens (IOL) in refractive lens exchange using an electronic reading desk.

Design: Prospective interventional before-and-after clinical study.

Methods: In total, 56 eyes of 28 patients were included.

View Article and Find Full Text PDF

Extended depth-of-focus (EDoF) presbyopia-correcting intraocular lens (IOL) models differ in their optical design and performance. In the laboratory, we compared the ray propagation and light intensity profiles of four IOLs: the non-diffractive AcrySof IQ Vivity (Alcon Inc., Fort Worth, TX, USA) and two diffractive models, Symfony ZXR00 (Johnson & Johnson Vision, Jacksonville, FL, USA) and AT Lara 829 MP (Carl Zeiss Meditec, Berlin, Germany).

View Article and Find Full Text PDF

Purpose: To compare the enlargement of the clear corneal incision from IOL implantation with 2 different intraocular lens (IOL) injectors: the AutonoMe preloaded with the Clareon IOL and the Multisert preloaded with the Vivinex IOL.

Setting: The David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany.

View Article and Find Full Text PDF