Background: The shape and microstructure of the human crystalline lens alter with ageing, and this has an effect on the optical properties of the eye. The aim of this study was to characterise the age-related differences in the morphology and transparency of the eye lenses of healthy subjects through the optical signal discontinuity (OSD) zones in optical coherence tomography (OCT) images. We also investigated the association of those changes with the optical quality of the eye and visual function.
View Article and Find Full Text PDFQuantitative evaluation of the human corneal grafts stored in the tissue banks is usually limited to endothelial cell density and central thickness. Swept-source OCT (SS-OCT) is capable of measuring the central curvatures of the corneal tissue prepared for transplantation without loss of sterileness, providing insights on its refractive state. The aim of the paper is to compare in vitro SS-OCT measurements with pre-excision values.
View Article and Find Full Text PDFCataract is one of the common causes of visual impairment due to opacification of the crystalline lens. Increased intraocular scattering affects the vision of cataract patients by reducing the quality of the retinal image. In this study, an amplitude modulation-based scatter compensation (AM-SC) method is developed to minimize the impact of straylight on the retinal image.
View Article and Find Full Text PDFDespite technological progress, we lack a consensus on the method of conducting automated bowel sound (BS) analysis and, consequently, BS tools have not become available to doctors. We aimed to briefly review the literature on BS recording and analysis, with an emphasis on the broad range of analytical approaches. Scientific journals and conference materials were researched with a specific set of terms (Scopus, MEDLINE, IEEE) to find reports on BS.
View Article and Find Full Text PDFThe geometry of contact lenses can be altered by wear but determining the changes that occur in soft contact lenses (SCLs) is challenging. This study aimed to investigate the shape alterations of daily disposable SCLs after wear using swept-source optical coherence tomography (SS-OCT). Forty-five eyes with myopia of - 3.
View Article and Find Full Text PDFPurpose: To measure geometrical changes in the anterior surface of the cornea after wearing silicon hydrogel (SiH) soft contact lenses continuously for 1 week.
Methods: Forty-three eyes with 3.0D of myopia and 22 eyes with 3.
Purpose: The purpose of this study was to characterize age-related changes in anterior human vitreous with 3-D swept source optical coherence tomography (SS-OCT) and evaluate associations with axial length (AL) and contrast sensitivity function (CSF).
Methods: There were 49 phakic eyes in 49 patients (40.0 ± 19.
A three-dimensional optical coherence tomography (OCT) crystalline lens imaging method based on oblique scanning and image stitching is presented. The method was designed to increase OCT imaging volume of crystalline lens . A long-range swept-source (SS)-OCT imaging system, which can measure the entire anterior segment of eye in a single acquisition, is used to acquire one central volume and 4 extra volumes with different angles between optical axis of OCT instrument and the pupillary axis.
View Article and Find Full Text PDFWhole eye visualization and morphometry are of high relevance in clinical practice. However, most standard ophthalmic OCT instruments are dedicated either to retinal or to anterior segment imaging. We demonstrate a swept source optical coherence tomography system (SS-OCT) that images both the whole anterior segment and the retina alternately using a single source and detector.
View Article and Find Full Text PDFContact lens wear causes mutual interactions between the ocular surface and the lens, which may affect comfort as well as vision. The aim of this study was to examine deformations in modern positive- and negative-powered silicone hydrogel soft contact lenses (SiH SCLs) after 7 days of continuous wear. This pre-post interventional study included 64 eyes: 42 eyes with myopia of -3.
View Article and Find Full Text PDFWe demonstrate three-dimensional (3-D) visualization of crystalline lens sutures in healthy eyes using swept source optical coherence tomography (SS-OCT). Volumetric data sets of the crystalline lenses were acquired and processed to obtain enhanced contrast projection images and to extract suture patterns in both anterior and posterior lens. The results presented different types of the sutures including Y-sutures, simple and complex star sutures.
View Article and Find Full Text PDFWe demonstrate a swept source OCT-based ocular biometer integrated with an air-puff stimulus to study the reaction of the eye to mechanical stimulation . The system enables simultaneous measurement of the stimulus strength and high-speed imaging of the eye dynamics along the visual axis. We characterize the stimulus and perform optimization of the data acquisition for a proper interpretation of the results.
View Article and Find Full Text PDFPurpose: To analyze the dynamics of all optical components of the eye and the behavior of the eyeball under air-puff conditions in vivo. To determine the impact of the intraocular pressure (IOP) on the air-puff-induced deformation of the eye.
Methods: Twenty eyes of 20 healthy subjects were included in this study.
We demonstrate an optimized optical platform for the three-dimensional (3-D) visualization of crystalline lens opacities in vivo in the eyes of patients with different types and grades of cataracts. We developed a prototype long-depth-range swept source optical coherence tomography (SS-OCT) instrument operating at the speed of 50 kA-scans/second and at the central wavelength of 1 μm to perform high-resolution imaging of the whole anterior segment of the eye. Volumetric data sets of cataractous eyes were acquired and processed to obtain contrast-enhanced high-resolution images of lenticular structures and opacifications.
View Article and Find Full Text PDFApplication of the air-puff swept source optical coherence tomography (SS-OCT) instrument to determine the influence of viscoelasticity on the relation between overall the air-puff force and corneal apex displacement of porcine corneas ex vivo is demonstrated. Simultaneous recording of time-evolution of the tissue displacement and air pulse stimulus allows obtaining valuable information related in part to the mechanical properties of the cornea. A novel approach based on quantitative analysis of the corneal hysteresis of OCT data is presented.
View Article and Find Full Text PDFThe lamina cribrosa is a primary site of damage in glaucoma. While mechanical distortion is hypothesized to cause reduction of axoplasmic flow, little is known about how the pores, which contains the retinal ganglion cell axons, traverse the lamina cribrosa. We investigated lamina cribrosa pore paths in vivo to quantify differences in tortuosity of pore paths between healthy and glaucomatous eyes.
View Article and Find Full Text PDFWe demonstrate the application of focus-tunable acousto-optic lens technology in confocal microscopy for a high-speed axial scanning of the object. The advantages of the proposed approach include high axial scan rate, no mechanical sample movement, no additional non-symmetric aberrations, and the control of the effective depth of focus. The acousto-optic lens operating at the focus tuning rate of 300 kHz is developed and implemented in scanning laser confocal microscopy.
View Article and Find Full Text PDFPurpose: To image, describe, and characterize different features visible in the crystalline lens of older adults with and without cataract when imaged three-dimensionally with a swept-source optical coherence tomography (SS-OCT) system.
Methods: We used a new SS-OCT laboratory prototype designed to enhance the visualization of the crystalline lens and imaged the entire anterior segment of both eyes in two groups of participants: patients scheduled to undergo cataract surgery, n = 17, age range 36 to 91 years old, and volunteers without visual complains, n = 14, age range 20 to 81 years old. Pre-cataract surgery patients were also clinically graded according to the Lens Opacification Classification System III.
Purpose: Evaluation of the effect of prelaminar tissue thickness on visualization of the lamina cribrosa (LC) using optical coherence tomography (OCT).
Methods: The optic nerve head (ONH) region was scanned using OCT. The quality of visible LC microstructure was assessed subjectively using a grading system and objectively by analyzing the signal intensity of each scan's superpixel components.
We present a novel optical configuration that allows for generation of ultra-high speed dynamic Bessel beams and dynamic bottle beams. The method is based on combination of the axisymmetric acousto-optic device and the spatial filtering enabled by a mask or a digital micromirror device. Selected features of dynamic non-diffracting beams and bottle beams are investigated using time-resolved approach with stroboscopic pulsed illumination, including spatial intensity distribution, spatial modulation factors, MHz-range temporal modulation, and scalability.
View Article and Find Full Text PDFPurpose: To investigate how the lamina cribrosa (LC) microstructure changes with distance from the central retinal vessel trunk (CRVT), and to determine how this change differs in glaucoma.
Methods: One hundred nineteen eyes (40 healthy, 29 glaucoma suspect, and 50 glaucoma) of 105 subjects were imaged using swept-source optical coherence tomography (OCT). The CRVT was manually delineated at the level of the anterior LC surface.
The labial minor salivary glands (LSGs) play a role in medical research and practice due to their superficial location and involvement in both systemic and localized diseases. Swept-source optical coherence tomography (OCT) is a noninvasive modality that enables in vivo, micrometer resolution, wide-field three-dimensional imaging in seconds. A purpose-built swept-source OCT instrument was employed to acquire three-dimensional datasets covering the area of 2.
View Article and Find Full Text PDFThe labial minor salivary glands (LSGs) are easily accessible mucus-secreting structures of the alimentary tract that may provide new information on the basis of gastrointestinal complications of cystic fibrosis (CF). It was shown that they are destructed in the course of cystic fibrosis. We employed wide-field, micrometer resolution in vivo optical coherence tomography to assess the surface density of LSGs in 18 patients with CF and 18 healthy subjects.
View Article and Find Full Text PDFWe develop high-resolution optical coherence tomography (OCT) system with high-speed acousto-optic tunable lens. Stroboscopic pulsed illumination is used for the first time to perform time-resolved OCT imaging with acousto-optic tunable focusing. The operation of ultrahigh-speed tunable acousto-optic lens is demonstrated theoretically and experimentally.
View Article and Find Full Text PDF