Publications by authors named "Irene Redaelli"

Purpose: This study analyzed inter-institute conformity and dose gradient variability of CyberKnife (CK) brain SRS/SRT plans. The feasibility of multi-center predictive models was investigated, aiming at guided/automated planning optimization.

Methods: Data from 335 clinical plans, delivered for single lesions in 1-5 fractions, were collected by 8 CK centers.

View Article and Find Full Text PDF

Introduction Image-guided robotic radiosurgery is an emerging minimally-invasive treatment option for trigeminal neuralgia (TN). Our group has treated 560 cases up to date, and report here the clinical outcomes of 387 treatments with three years follow-up. This study represents the largest single-center experience on CyberKnife radiosurgery for the treatment of TN so far reported.

View Article and Find Full Text PDF

Purpose: The aims of this study were: (i) to validate in a multi-site context the suitability of the IBA Razor silicon diode detector for CyberKnife relative dosimetry. (ii) to fit the multi-center experimental data into a function relating the field output factors to the effective field size (EFS).

Methods And Materials: Ratio of detector readings in clinical and reference field (OF) and beam profiles were acquired on five CyberKnife units for fixed collimator diameters (range 5-60 mm), using both Razor and PTW 60017 diodes.

View Article and Find Full Text PDF

Purpose: When a lung lesion is detected by only one couple of X-ray tube and image detector integrated with CyberKnife®, the fiducial-less tracking is limited to 1-view (34% of lung treatments at Centro Diagnostico Italiano). The aim of the study was mainly to determine the margin needed to take into account the localization uncertainty along the blind view (out-of-plane direction).

Methods: 36 patients treated in 2-view tracking modality (127 fractions in total) were included in the study.

View Article and Find Full Text PDF

Purpose: New promising detectors are available for measuring small field size output factors (OFs). This study focused on a multicenter evaluation of two new generation detectors for OF measurements on CyberKnife systems.

Methods: PTW-60019 microDiamond and W1 plastic scintillation detector (PSD) were used to measure OFs on eight CyberKnife units of various generations for 5-60mm fixed cones.

View Article and Find Full Text PDF

Purpose: A large-scale multi-institutional planning comparison on lung cancer SABR is presented with the aim of investigating possible criticism in carrying out retrospective multicentre data analysis from a dosimetric perspective.

Methods: Five CT series were sent to the participants. The dose prescription to PTV was 54Gy in 3 fractions of 18Gy.

View Article and Find Full Text PDF

Background: A multidisciplinary and multi-institutional working group applied the Failure Mode and Effects Analysis (FMEA) approach to assess the risks for patients undergoing Stereotactic Body Radiation Therapy (SBRT) treatments for lesions located in spine and liver in two CyberKnife® Centres.

Methods: The various sub-processes characterizing the SBRT treatment were identified to generate the process trees of both the treatment planning and delivery phases. This analysis drove to the identification and subsequent scoring of the potential failure modes, together with their causes and effects, using the risk probability number (RPN) scoring system.

View Article and Find Full Text PDF

Objective: Hyperferritinemia is frequent in chronic liver diseases of any cause, but the extent to which ferritin truly reflects iron stores is variable. In these patients, both liver iron and fat are found in variable amount and association. Liver biopsy is often required to quantify liver fat and iron, but sampling variability and invasiveness limit its use.