Objectives: Hepatic venous pressure gradient (HVPG) is considered the standard in quantifying portal hypertension, but can be unreliable in dialysis patients. A noninvasive ultrasound technique, subharmonic-aided pressure estimation (SHAPE), may be a valuable surrogate of these pressure estimates. This study compared SHAPE and HVPG with pathology findings for fibrosis in dialysis patients.
View Article and Find Full Text PDFFor site-specific diseases such as atherosclerosis, it is desirable to noninvasively and locally deliver therapeutics for extended periods of time. High-intensity focused ultrasound (HIFU) provides targeted drug delivery, yet remains unable to sustain delivery beyond the HIFU treatment time. Furthermore, methods to validate HIFU-enhanced drug delivery remain limited.
View Article and Find Full Text PDFPolymer nanoparticles and microparticles have been used primarily for drug delivery. There is now growing interest in further developing polymer-based solid cavitation agents to also enhance ultrasound imaging. We previously reported on a facile method to produce hollow poly(lactic-co-glycolic acid) (PLGA) microparticles with different diameters and degrees of porosity.
View Article and Find Full Text PDFBackground: Portal hypertension is the underlying cause of most complications associated with cirrhosis, with the hepatic venous pressure gradient (HVPG) used for diagnosis and disease progression. Subharmonic imaging (SHI) is a contrast-specific imaging technique receiving at half the transmit frequency resulting in better tissue suppression.
Aims: To determine whether the presence of optimized SHI signals inside the hepatic vein can be used as a screening test for portal hypertension.
Noninvasive, accurate measurement of pressures within the human body has long been an important but elusive clinical goal. Contrast agents for ultrasound imaging are gas-filled, encapsulated microbubbles (diameter < 10 μm) that traverse the entire vasculature and enhance signals by up to 30 dB. These microbubbles also produce nonlinear oscillations at frequencies ranging from the subharmonic (half of the transmit frequency) to higher harmonics.
View Article and Find Full Text PDFRationale And Objective: Subharmonic aided pressure estimation (SHAPE) is based on the inverse relationship between the subharmonic amplitude of ultrasound contrast microbubbles and ambient pressure. The aim of this study was to verify if SHAPE can accurately monitor disease progression in patients identified with portal hypertension.
Materials & Methods: A modified Logiq 9 scanner with a 4C curvi-linear probe (GE, Waukesha, WI) was used to acquire SHAPE data (transmitting and receiving at 2.
Non-surgical treatment options for uterine fibroids are uterine artery embolization (UAE), high-intensity focused ultrasound ablation (HIFUA), and percutaneous microwave ablation (PMWA). Magnetic resonance imaging (MRI) is the reference standard imaging method before and after these procedures. Contrast-enhanced ultrasound (CEUS) has been studied as an alternative to MRI for evaluating the fibroids' characteristics and responses to non-surgical treatments.
View Article and Find Full Text PDFBackground The current standard for assessing the severity of portal hypertension is the invasive acquisition of hepatic venous pressure gradient (HVPG). A noninvasive US-based technique called subharmonic-aided pressure estimation (SHAPE) could reduce risk and enable routine acquisition of these pressure estimates. Purpose To compare quantitative SHAPE to HVPG measurements to diagnose portal hypertension in participants undergoing a transjugular liver biopsy.
View Article and Find Full Text PDFSubharmonic-aided pressure estimation (SHAPE) estimates hydrostatic pressure using the inverse relationship with subharmonic amplitude variations of ultrasound contrast agents (UCAs). We studied the impact of varying incident acoustic outputs (IAO), UCA concentration, and hematocrit on SHAPE. A Logiq 9 scanner with a 4C curvilinear probe (GE, Milwaukee, Wisconsin) was used with Sonazoid (GE Healthcare, Oslo, Norway) transmitting at 2.
View Article and Find Full Text PDFObjectives: Subharmonic imaging (SHI) is a technique that uses the nonlinear oscillations of microbubbles when exposed to ultrasound at high pressures transmitting at the fundamental frequency ie, f and receiving at half the transmit frequency (ie, f /2). Subharmonic aided pressure estimation (SHAPE) is based on the inverse relationship between the subharmonic amplitude of the microbubbles and the ambient pressure change.
Methods: Eight waveforms with different envelopes were optimized with respect to acoustic power at which the SHAPE study is most sensitive.
Indian J Physiol Pharmacol
October 2012
Subjective well being has been widely researched in the past few decades and in practical terms it is a term that encompasses the various ways people evaluate their lives including concepts such as life satisfaction, work and health etc. Since, it is well known, that psychological factors including stress, anxiety, poor sleeping habits etc are known to be important causes of life style disorders like myocardial infraction, we started with the hypothesis that subjective well being of post acute MI patients must be poorer compared to normal subjects in the same age group. A comparative study between normal subjects and post acute myocardial infarction patients was undertaken to compare their subjective well being and current mental health status, at Safdarjung Hospital, New Delhi using standardized questionnaires.
View Article and Find Full Text PDF