Polymer-based solid microstructures (MSts) have the potential to significantly increase the quantity and range of drugs that can be administered across the skin. MSt arrays are used to demonstrate their capacity to bypass the skin barrier and enhance permeability by creating microchannels through the , in a minimally invasive manner. This study is designed to demonstrate the ability of MSts to exceed the current boundaries for transdermal delivery of compounds with different molecular weights, partition coefficients, acid dissociation constants, melting points, and water solubilities.
View Article and Find Full Text PDFObjective: To evaluate the fracture resistance and failure types of modified H-designed intradental short retention preparation for computer-aided design/computer-assisted manufacture (CAD/CAM) restorations, in cases where no ferrule is possible.
Method And Materials: A combined finite element analysis and in vitro testing was employed. Forty extracted single-rooted premolars were selected and prepared for the following four groups (n = 10 per group): Group A, H-post preparation restored with glass-ceramic crowns; group B, H-post preparation restored with lithium disilicate crowns; group C, endocrowns (negative control group); and group D, 2-mm ferrule preparation and restoration with fiber posts (positive control).
Purpose: The purpose of this study was to evaluate the influence of buccal and lingual wall convergence angles on the ability of the preparation to resist rotational displacement.
Materials And Methods: An intact premolar digitized by micro-CT yielded a 3D reproduction of a human tooth. Simulated crown preparations with known buccolingual axial wall convergence angles (4°, 8°, 12°, 16°, 20°, 24°, 28° 32°), sloped-shoulder marginal area, and occlusal reduction were created and restored with a ceramic crown.
Increases in bone strains above a certain threshold have a positive effect on bone mass, whereas reductions in strain magnitude lead to bone loss and osteopenia; the term 'mechanostat' has been introduced to describe this tissue-level negative feedback mechanism. The mechanobiology of bone and particularly alveolar bone is poorly understood, and whether the mechanostat theory has any relevance to explaining the osseous changes that occur during orthodontic tooth movement remains unclear. To investigate the relationship further, an expansile force of 0.
View Article and Find Full Text PDFAm J Orthod Dentofacial Orthop
February 2009
Introduction: The initial mechanical response to orthodontic loading comprises biologic reactions that remain unclear, despite their clinical significance. We used a 3-dimensional finite element analysis to investigate the stress-strain responses of teeth to orthodontic loading.
Methods: The model was derived from computed tomography data, with adequate boundary conditions and tissue characterization, with orthodontic hardware to provide a more accurate reflection of events during orthodontic therapy.
Forensic Sci Med Pathol
April 2009
Knowledge of the biomechanical dynamics of blunt force trauma is indispensable for forensic reconstruction of a wounding event. In this study, we describe and interpret wound features on a synthetic skin model under defined laboratory conditions. To simulate skin and the sub-dermal tissues we used open-celled polyurethane sponge (foam), covered by a silicone layer.
View Article and Find Full Text PDFForensic Sci Med Pathol
April 2009
Despite a long history of gross and microscopic descriptions of blunt and sharp force injury to the dermal tissues, few have addressed the mechanisms underlying such trauma. The need to develop an understanding of how non-ballistic injury occurs calls for an ability to biomechanically model the process. We recently introduced a basic skin and subcutaneous model, which we used to investigate wounding from a spherical object.
View Article and Find Full Text PDFThis article introduces a new way of recording intraoral pressures from a range of locations within the oral cavity. To measure pressure flow dynamics during swallowing, we fitted eight miniature pressure transducers capable of measuring absolute pressures to a chrome-cobalt palatal appliance with a labial bow. Unlike previous devices, our design provides a rigid, custom-fitted platform for the simultaneous recording of pressures at eight locations within the oral cavity during function.
View Article and Find Full Text PDFAs part of a more extensive investigation of skin wounding mechanisms, we studied wounds created by five common screwdrivers (straight, star, square or Robertson, Posidriv and Phillips) on the shaven foreheads of 12 freshly slaughtered pigs. We fixed the different screwdriver heads to a 5-kg metal cylinder which was directed vertically onto each pig head by a droptube of 700 mm length. We examined skin lesions by photography and also by scanning electron microscopy (SEM).
View Article and Find Full Text PDFOne of the most fundamental yet unanswered questions of human evolution is that of the development of the chin. Whereas it is known that the chin, or mentum osseum, is an unique anatomical feature of modern humans that emerged during the Middle and Late Pleistocene, its origin and biomechanical significance are the subjects of intense controversy. Theories range from the suggestion that the chin evolved as a result of progressive reduction of the dental arch, which left it as a protrusion, to the hypothesis that it provided resistance to mandibular bending during mastication.
View Article and Find Full Text PDF