The serological marker melanoma inhibitory activity (MIA) has been shown to be significantly higher in the serum of patients suffering from metastatic uveal melanoma than in progression-free patients. The objective of this study was to calculate a meaningful receiver operating characteristic (ROC) curve for MIA based on a large patient collective and to find an appropriate threshold value. MIA tumor marker levels of 503 outpatients suffering from uveal melanoma were evaluated using enzyme-linked immunosorbent assay.
View Article and Find Full Text PDFBackground: Evaluation of the protein osteopontin (OPN) as a potential new marker in comparison to melanoma inhibitory activity (MIA) for screening and detection of metastatic uveal melanoma.
Methods: Plasma levels of 32 patients with uveal melanoma were analyzed for OPN and MIA by enzyme-linked immunosorbent assay (ELISA). Fourteen of these patients had clinically detectable liver metastases.