Publications by authors named "Imramsjah M van der Bom"

Purpose: Dose calculation for transarterial radioembolization (TARE) with glass yttrium-90 (Y) labeled microspheres is based on liver lobe and tumor volumes, currently measured from preprocedural MRI or CT. The variable time between MRI and radioembolization may not account for relevant tumor progression. Advances in cone beam computed tomography (CBCT) allow for intra-procedural assessment of these volumes that avoids this factor.

View Article and Find Full Text PDF

Purpose: To determine the true distribution of radiopaque beads (ROBs) after hepatic embolization in swine as imaged by micro-computed tomography (microCT) compared with in vivo cone-beam computerized tomography (CT) imaged at different kVp settings.

Materials And Methods: Swine (n = 3) underwent hepatic transarterial embolization (n = 6) with the use of 70-150-μm ROBs under fluoroscopic guidance. After stasis, in vivo cone-beam CT was performed at 120, 100, and 80 kVp.

View Article and Find Full Text PDF

Purpose: To compare image quality and radiation exposure between a new angiographic imaging system and the preceding generation system during uterine artery embolization (UAE).

Materials And Methods: In this retrospective, IRB-approved two-arm study, 54 patients with symptomatic uterine fibroids were treated with UAE on two different angiographic imaging systems. The new system includes optimized acquisition parameters and real-time image processing algorithms.

View Article and Find Full Text PDF

Objective: The transradial approach (TRA) has been shown to reduce the morbidity and mortality associated with arterial coronary interventions. Selective internal radiation therapy (SIRT) performed via the TRA can enhance patient comfort, compared with the traditional transfemoral approach (TFA), by allowing immediate ambulation and precluding potential complications associated with the TFA, such as closure device injury or retroperitoneal hematoma. We report our initial experience with and technique for using the TRA for SIRT.

View Article and Find Full Text PDF

Purpose: To compare cone-beam computed tomography (CT) navigation vs conventional CT image guidance during biopsies.

Materials And Methods: Patients scheduled for image-guided biopsies were prospectively and randomly assigned to conventional CT guidance vs cone-beam CT navigation. Radiation dose, accuracy of final needle position, rate of histopathologic diagnosis, and number of needle repositions to reach the target (defined as pullback to adjust position) were compared.

View Article and Find Full Text PDF

Purpose: To compare the visibility of liver metastases on dual-phase cone-beam CT (DP-CBCT) and digital subtraction angiography (DSA), with reference to preinterventional contrast-enhanced magnetic resonance imaging (CE-MRI) of the liver.

Methods: This IRB-approved, retrospective study included 28 patients with neuroendocrine (NELM), colorectal (CRCLM), or sarcoma (SLM) liver metastases who underwent DP-CBCT during intra-arterial therapy (IAT) between 01/2010 and 10/2014. DP-CBCT was acquired after a single contrast agent injection in the tumor-feeding arteries at early and delayed arterial phases (EAP and DAP).

View Article and Find Full Text PDF
Article Synopsis
  • The study introduces LC Bead LUMI™, a new microspherical embolic agent that can be imaged during transarterial embolization of liver tumors, designed for improved tracking during procedures.
  • The methodology involved injecting iodinated microbeads into the hepatic arteries of three patients, employing advanced imaging techniques like cone beam CT and digital subtraction angiography to monitor the embolization process.
  • Results showed that the microbeads could be effectively monitored, revealing areas of potential under-treatment within tumors; further research is suggested to better assess bead distribution as a factor in treatment effectiveness.
View Article and Find Full Text PDF

Objective: To assess the radiation dose reduction during uterine artery embolization utilizing dose reduction technology.

Methods: A total of 58 women underwent uterine artery embolization. A total of 26 procedures were performed in a standard fluoroscopy suite; 32 procedures were performed utilizing a novel imaging platform.

View Article and Find Full Text PDF

Clinical studies have demonstrated the efficacy of stent supported coiling for intra-cranial aneurysm treatment. Despite encouraging outcomes, some matters are yet to be addressed. In particular closed stent designs are influenced by the delivery technique and may suffer from under-expansion, with the typical effect of "hugging" the inner curvature of the vessel which seems related to adverse events.

View Article and Find Full Text PDF

Background And Purpose: We aimed to compare the performance of the ZeroGravity (ZG) system (radiation protection system composed by a suspended lead suit) against the use of standard protection (lead apron (LA), thyroid shield, lead eyeglasses, table skirts, and ceiling suspended shield) in neuroangiography procedures.

Materials And Methods: Radiation exposure data were prospectively collected in consecutive neuroendovascular procedures between December 2014 and February 2015. Operator No 1 was assigned to the use of an LA (plus lead glasses, thyroid shield, and a 1 mm hanging shield at the groin) while operator No 2 utilized the ZG system.

View Article and Find Full Text PDF

Purpose: To compare liver coverage and tumor detectability by using preprocedural magnetic resonance (MR) images as a reference, as well as radiation exposure of cone-beam computed tomography (CT) with different rotational trajectories.

Materials And Methods: Fifteen patients (nine men and six women; mean age ± standard deviation, 65 years ± 5) with primary or secondary liver cancer were retrospectively included in this institutional review board-approved study. A modified cone-beam CT protocol was used in which the C-arm rotates from +55° to -185° (open arc cone-beam CT) instead of -120° to +120° (closed arc cone-beam CT).

View Article and Find Full Text PDF

Background: Dantrolene is neuroprotective in animal models and may attenuate cerebral vasospasm (cVSP) in human aneurysmal subarachnoid haemorrhage (aSAH). We evaluated safety, feasibility and tolerability of intravenous dantrolene (IV-D) in patients with aSAH.

Methods: In this single-centre, randomised, double blind, placebo-controlled trial, 31 patients with aSAH were randomised to IV-D 1.

View Article and Find Full Text PDF

Background And Purpose: Tandem vascular occlusions are an important cause of acute ischemic stroke (AIS) and present unique treatment challenges. We report our experience of managing a subset of AIS patients with extracranial vascular stenting/angioplasty and intracranial revascularization.

Methods: Consecutive patients who presented at three centers with AIS from tandem vascular occlusions confirmed by brain and neck CT imaging were included in the study.

View Article and Find Full Text PDF

Background: Intracranial in-stent hyperplasia is a stroke-associated complication that requires routine surveillance.

Objective: To compare the results of in vivo experiments to determine the accuracy and precision of in-stent hyperplasia measurements obtained with modified C-arm contrast-enhanced, cone-beam CT (CE-CBCT) imaging with those obtained by 'gold standard' histomorphometry. Additionally, to carry out clinical analyses comparing this CE-CBCT protocol with digital subtraction angiography (DSA).

View Article and Find Full Text PDF

Three years following endovascular embolization of a 3 mm ruptured arteriovenous malformation (AVM) of the left superior colliculus in a 42-year-old man, digital subtraction angiography showed continuous regrowth of the lesion. Thin-slice MRI acquired for treatment planning did not show the AVM nidus. The patient was brought back to the angiography suite for high-resolution contrast-enhanced cone beam CT (VasoCT) acquired using an angiographic c-arm system.

View Article and Find Full Text PDF

Three years following endovascular embolization of a 3 mm ruptured arteriovenous malformation (AVM) of the left superior colliculus in a 42-year-old man, digital subtraction angiography showed continuous regrowth of the lesion. Thin-slice MRI acquired for treatment planning did not show the AVM nidus. The patient was brought back to the angiography suite for high-resolution contrast-enhanced cone beam CT (VasoCT) acquired using an angiographic c-arm system.

View Article and Find Full Text PDF

Purpose: In this report, the feasibility of using blood as an agent for Chemical Exchange Saturation Transfer (CEST) effect is investigated.

Methods: The CEST effect of porcine blood samples was investigated on a 3.0 T MRI scanner using various power levels and on a 14.

View Article and Find Full Text PDF

Introduction: Convection-enhanced delivery (CED) has been shown to be an effective method of administering macromolecular compounds into the brain that are unable to cross the blood-brain barrier. Because the administration is highly localized, accurate cannula placement by minimally invasive surgery is an important requisite. This paper reports on the use of an angiographic c-arm system which enables truly frameless multimodal image guidance during CED surgery.

View Article and Find Full Text PDF