Purpose: To evaluate the accuracy of cone-beam computed tomography (CT)-based augmented fluoroscopy (AF) image guidance for endobronchial navigation to peripheral lung targets.
Methods: Prototypic endobronchial navigation AF software that superimposed segmented airways, targets, and pathways based on cone-beam CT onto fluoroscopy images was evaluated ex vivo in fixed swine lungs and in vivo in healthy swine (n = 4) without a bronchoscope. Ex vivo and in vivo (n = 3) phase 1 experiments used guide catheters and AF software version 1, whereas in vivo phase 2 (n = 1) experiments also used an endovascular steerable guiding sheath, upgraded AF software version 2, and lung-specific low-radiation-dose protocols.
GM2 gangliosidoses, including Tay-Sachs disease and Sandhoff disease, are lysosomal storage disorders caused by deficiencies in β-N-acetylhexosaminidase (Hex). Patients are afflicted primarily with progressive central nervous system (CNS) dysfunction. Studies in mice, cats, and sheep have indicated safety and widespread distribution of Hex in the CNS after intracranial vector infusion of AAVrh8 vectors encoding species-specific Hex α- or β-subunits at a 1:1 ratio.
View Article and Find Full Text PDFObjective: The transradial approach (TRA) has been shown to reduce the morbidity and mortality associated with arterial coronary interventions. Selective internal radiation therapy (SIRT) performed via the TRA can enhance patient comfort, compared with the traditional transfemoral approach (TFA), by allowing immediate ambulation and precluding potential complications associated with the TFA, such as closure device injury or retroperitoneal hematoma. We report our initial experience with and technique for using the TRA for SIRT.
View Article and Find Full Text PDFObjective: To assess the radiation dose reduction during uterine artery embolization utilizing dose reduction technology.
Methods: A total of 58 women underwent uterine artery embolization. A total of 26 procedures were performed in a standard fluoroscopy suite; 32 procedures were performed utilizing a novel imaging platform.
Clinical studies have demonstrated the efficacy of stent supported coiling for intra-cranial aneurysm treatment. Despite encouraging outcomes, some matters are yet to be addressed. In particular closed stent designs are influenced by the delivery technique and may suffer from under-expansion, with the typical effect of "hugging" the inner curvature of the vessel which seems related to adverse events.
View Article and Find Full Text PDFBackground And Purpose: We aimed to compare the performance of the ZeroGravity (ZG) system (radiation protection system composed by a suspended lead suit) against the use of standard protection (lead apron (LA), thyroid shield, lead eyeglasses, table skirts, and ceiling suspended shield) in neuroangiography procedures.
Materials And Methods: Radiation exposure data were prospectively collected in consecutive neuroendovascular procedures between December 2014 and February 2015. Operator No 1 was assigned to the use of an LA (plus lead glasses, thyroid shield, and a 1 mm hanging shield at the groin) while operator No 2 utilized the ZG system.
Background: Dantrolene is neuroprotective in animal models and may attenuate cerebral vasospasm (cVSP) in human aneurysmal subarachnoid haemorrhage (aSAH). We evaluated safety, feasibility and tolerability of intravenous dantrolene (IV-D) in patients with aSAH.
Methods: In this single-centre, randomised, double blind, placebo-controlled trial, 31 patients with aSAH were randomised to IV-D 1.
Background And Purpose: Tandem vascular occlusions are an important cause of acute ischemic stroke (AIS) and present unique treatment challenges. We report our experience of managing a subset of AIS patients with extracranial vascular stenting/angioplasty and intracranial revascularization.
Methods: Consecutive patients who presented at three centers with AIS from tandem vascular occlusions confirmed by brain and neck CT imaging were included in the study.
Background: Intracranial in-stent hyperplasia is a stroke-associated complication that requires routine surveillance.
Objective: To compare the results of in vivo experiments to determine the accuracy and precision of in-stent hyperplasia measurements obtained with modified C-arm contrast-enhanced, cone-beam CT (CE-CBCT) imaging with those obtained by 'gold standard' histomorphometry. Additionally, to carry out clinical analyses comparing this CE-CBCT protocol with digital subtraction angiography (DSA).
Three years following endovascular embolization of a 3 mm ruptured arteriovenous malformation (AVM) of the left superior colliculus in a 42-year-old man, digital subtraction angiography showed continuous regrowth of the lesion. Thin-slice MRI acquired for treatment planning did not show the AVM nidus. The patient was brought back to the angiography suite for high-resolution contrast-enhanced cone beam CT (VasoCT) acquired using an angiographic c-arm system.
View Article and Find Full Text PDFThree years following endovascular embolization of a 3 mm ruptured arteriovenous malformation (AVM) of the left superior colliculus in a 42-year-old man, digital subtraction angiography showed continuous regrowth of the lesion. Thin-slice MRI acquired for treatment planning did not show the AVM nidus. The patient was brought back to the angiography suite for high-resolution contrast-enhanced cone beam CT (VasoCT) acquired using an angiographic c-arm system.
View Article and Find Full Text PDFPurpose: In this report, the feasibility of using blood as an agent for Chemical Exchange Saturation Transfer (CEST) effect is investigated.
Methods: The CEST effect of porcine blood samples was investigated on a 3.0 T MRI scanner using various power levels and on a 14.
Introduction: Convection-enhanced delivery (CED) has been shown to be an effective method of administering macromolecular compounds into the brain that are unable to cross the blood-brain barrier. Because the administration is highly localized, accurate cannula placement by minimally invasive surgery is an important requisite. This paper reports on the use of an angiographic c-arm system which enables truly frameless multimodal image guidance during CED surgery.
View Article and Find Full Text PDF