IEEE Trans Ultrason Ferroelectr Freq Control
December 2024
Velocity estimation in ultrasound imaging is a technique to measure the speed and direction of blood flow. The flow velocity in small blood vessels, i.e.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
August 2024
Super-resolution ultrasound imaging using the erythrocytes (SURE) has recently been introduced. The method uses erythrocytes as targets instead of fragile microbubbles (MBs). The abundance of erythrocyte scatterers makes it possible to acquire SURE data in just a few seconds compared with several minutes in ultrasound localization microscopy (ULM) using MBs.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
August 2024
A new approach for vascular super-resolution (SR) imaging using the erythrocytes as targets (SUper-Resolution ultrasound imaging of Erythrocytes (SURE) imaging) is described and investigated. SURE imaging does not require fragile contrast agent bubbles, making it possible to use the maximum allowable mechanical index (MI) for ultrasound scanning for an increased penetration depth. A synthetic aperture (SA) ultrasound sequence was employed with 12 virtual sources (VSs) using a 10-MHz GE L8-18i-D linear array hockey stick probe.
View Article and Find Full Text PDFIndividuals with diabetes at risk of developing diabetic kidney disease (DKD) are challenging to identify using currently available clinical methods. Prognostic accuracy and initiation of treatment could be improved by a quantification of the renal microvascular rarefaction and the increased vascular tortuosity during the development of DKD. Super-resolution ultrasound (SRUS) imaging is an in vivo technique capable of visualizing blood vessels at sizes below 75 µm.
View Article and Find Full Text PDFAn ultra-narrow 40-nm slotted waveguide is fabricated to enable highly efficient, electro-optic polymer modulators. Our measurement results indicate that VL's below ∼ 1.19 V.
View Article and Find Full Text PDFObesity is a risk factor of chronic kidney disease (CKD), leading to alterations in the renal vascular structure. This study tested if renal vascular density and tortuosity was quantifiable in vivo in obese rats using microbubble-based super-resolution ultrasound imaging. The kidneys of two 11-week-old and two 20-week-old male obese Zucker rats were compared with age-matched male lean Zucker rats.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
October 2022
Row-column (RC) arrays have the potential to yield full 3-D ultrasound imaging with a greatly reduced number of elements compared to fully populated arrays. They, however, have several challenges due to their special geometry. This review article summarizes the current literature for RC imaging and demonstrates that full anatomic and functional imaging can attain a high quality using synthetic aperture (SA) sequences and modified delay-and-sum beamforming.
View Article and Find Full Text PDFOptical modulators are vital for many applications, including telecommunication, data communication, optical computing, and microwave photonic links. A compact modulator with low voltage drive requirement, low power, high speed, and compatibility with CMOS foundry process is highly desirable. Current modulator technologies in Si suffer from trade-offs that constrain their power, performance (speed, drive voltage), and area.
View Article and Find Full Text PDFSuper-resolution ultrasound imaging, based on the localization and tracking of single intravascular microbubbles, makes it possible to map vessels below 100 µm. Microbubble velocities can be estimated as a surrogate for blood velocity, but their clinical potential is unclear. We investigated if a decrease in microbubble velocity in the arterial and venous beds of the renal cortex, outer medulla, and inner medulla was detectable after intravenous administration of the α1-adrenoceptor antagonist prazosin.
View Article and Find Full Text PDFMicrobubble (MB) tracking plays an important role in ultrasound super-resolution imaging (SRI) by enabling velocity estimation and improving image quality. This work presents a new hierarchical Kalman (HK) tracker to achieve better performance at scenarios with high concentrations of MBs and high localization uncertainty. The method attempts to follow MBs with different velocity ranges using different Kalman filters.
View Article and Find Full Text PDFSuper-resolution ultrasound imaging (SRUS) enables in vivo microvascular imaging of deeper-lying tissues and organs, such as the kidneys or liver. The technique allows new insights into microvascular anatomy and physiology and the development of disease-related microvascular abnormalities. However, the microvascular anatomy is intricate and challenging to depict with the currently available imaging techniques, and validation of the microvascular structures of deeper-lying organs obtained with SRUS remains difficult.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
October 2021
Super-resolution (SR) imaging has the potential of visualizing the microvasculature down to the 10- [Formula: see text] level, but motion induced by breathing, heartbeats, and muscle contractions are often significantly above this level. This article, therefore, introduces a method for estimating tissue motion and compensating for this. The processing pipeline is described and validated using Field II simulations of an artificial kidney.
View Article and Find Full Text PDFIn vivo monitoring of the microvasculature is relevant since diseases such as diabetes, ischemia, or cancer cause microvascular impairment. Super-resolution ultrasound imaging allows in vivo examination of the microvasculature by detecting and tracking sparsely distributed intravascular microbubbles over a minute-long period. The ability to create detailed images of the renal vasculature of Sprague-Dawley rats using a modified clinical ultrasound platform was investigated in this study.
View Article and Find Full Text PDF