Publications by authors named "Iman Abdel Wahab Radi"

Background: The passive fit of 3-unit implant supported prefabricated metal screw-retained prosthesis before implant placement might be difficult. Hence, we aim to evaluate the passive fit and time efficiency of CAD/CAM 3-unit implant supported fixed prostheses that were constructed based on virtual versus those based on actual implant positions in Kennedy Class I models.

Methods: A sample of 5 Kennedy class I models with thin wiry ridges were restored by 20 frameworks bilaterally, 10 based on actual (group A) and 10 based on virtual (group V) implant positions.

View Article and Find Full Text PDF

Purpose: This pilot clinical trial aimed to investigate accuracy of intra-oral scanning (IOS) with and without artificial reference markers in capturing total, subtotal and congenital nasal defects.

Basic Procedures: Thirteen patients with 3 types of nasal defects were selected and digitally scanned using an IOS with (ScM) and without artificial markers (Sc). Patients were grouped as follows; Group T (total nasal defect), Group P (partial/subtotal nasal defect), Group C (congenital defect).

View Article and Find Full Text PDF

Purpose: To investigate temporomandibular disorder (TMD) prevalence as well as potential TMD risk factors among postgraduate students.

Materials And Methods: In this cross-sectional and correlation study, 1,255 postgraduate students from different universities were recruited to answer Fonseca's Anamnestic Index (FAI) in addition to collected demographic data and relevant dental history. FAI was used to classify TMD severity.

View Article and Find Full Text PDF

Article Title And Bibliographic Information: Minakuchi H, Fujisawa M, Abe Y, Iida T, Oki K, Okura K, Tanabe N, Nishiyama A. Managements of sleep bruxism in adult: A systematic review. Jpn Dent Sci Rev.

View Article and Find Full Text PDF

Article Title And Bibliographic Information: Gonçalves F, Campestrini VLL, Rigo-Rodrigues MA, Zanardi PR. Effect of the attachment system on the biomechanical and clinical performance of overdentures: A systematic review. J Prosthet Dent.

View Article and Find Full Text PDF

Objectives: : The goal of this in vitro study was to evaluate stress patterns and retention of ball and socket and 2 telescopic attachments of different convergence angles retaining an implant-supported overdenture prosthesis.

Materials And Methods: : This study was carried out on an edentulous mandibular acrylic resin educational model. Four dummy implants, 3.

View Article and Find Full Text PDF