Background: To assess marginal bone loss and soft tissue health around two-implant mandibular overdenture retained with milled versus selective laser-melted cobalt chromium (Co-Cr) bars.
Method: This research was set to be a parallel, triple-blinded, randomised controlled trial. Twenty completely edentulous patients received new conventional complete dentures according to conventional techniques.
This study aimed to assess the accuracy of the marginal fit of 2 implant-supported overdenture bars fabricated with selective laser melting technology, using polyvinyl siloxane and vinyl siloxane ether impression materials and different impression techniques. Two implants with multi-unit abutments were inserted in a 3D-printed mandibular model and used as a reference model, then duplicated into a stone cast to fabricate custom trays for obtaining impressions with polyvinyl siloxane and vinyl siloxane ether impression materials, using both open and closed-tray techniques. This resulted in a total of 4 groups, each with 8 specimens.
View Article and Find Full Text PDFPurpose: to examine the electromyographic (EMG) activity of the masseter muscles in patients with conventional dentures and compare it to EMG activity of fixed prosthesis, and milled bar overdentures used to rehabilitate mandibular atrophied ridges according to the All-on-4 concept.
Methods: Eighteen edentulous subjects with atrophied mandibles received complete dentures (CD, control). After 3 months, four implants were installed between the mental foramina according to the "All-on-4" protocol and loaded immediately.