Publications by authors named "Imachi K"

Copper is a transition metal element with significant effects on the morphological development and secondary metabolism of actinobacteria. In some microorganisms, copper-binding natural products are employed to modulate copper homeostasis, although their significance in actinobacteria remains largely unknown. Here, we identified the biosynthetic genes of the diisocyanide natural product hazimycin in Kitasatospora purpeofusca HV058, through gene knock-out and heterologous expression.

View Article and Find Full Text PDF
Article Synopsis
  • CA 15-3 is a tumor marker for breast cancer primarily used to monitor therapy in advanced cases, but its role in systemic sclerosis-associated lung disease (SSc-ILD) is unclear.* -
  • A case study involving a 63-year-old woman with recurrent breast cancer and SSc-ILD highlighted the importance of recognizing lung complications during cancer treatment, especially after she reported shortness of breath after chemotherapy.* -
  • The study emphasizes the need for a differential diagnosis of lung involvement in breast cancer patients, indicating that elevated CA 15-3 levels can be linked to conditions like SSc-ILD instead of just cancer progression.*
View Article and Find Full Text PDF

Background: Spontaneous regression (SR) is a rare phenomenon in which a cancer disappears or remits without treatment. We report a case of breast cancer that showed spontaneous tumor regression in the surgical specimen after core needle biopsy.

Case Presentation: A 59-year-old woman came to our hospital complaining of a painful lump in the right breast.

View Article and Find Full Text PDF

The utility of nitroglycerin is well established in coronary angiography but less so in other surgical fields. In this study, the authors investigated the utility of preoperative computed tomographic angiography after sublingual nitroglycerin followed by three-dimensional visualization for selecting suitable perforators in planning the free anterolateral thigh flap. The authors performed preoperative computed tomographic angiography following sublingual nitroglycerin (after screening for contraindications) in patients for whom reconstructive surgery with the free anterolateral thigh flap was planned.

View Article and Find Full Text PDF

The helical flow pump (HFP) was invented to be an ideal pump for developing the TAH and the helical flow TAH (HFTAH) using two HFPs has been developed. However, since the HFP is quite a new pump, hydrodynamic characteristics inside the pump are not clarified. To analyze hydrodynamic characteristics of the HFP, flow visualization study using the particle image velocimetry and computational fluid dynamics analysis were performed.

View Article and Find Full Text PDF

The helical flow pump (HFP) was invented to develop a total artificial heart at the University of Tokyo in 2005. The HFP consists of the multi-vane impeller involving rotor magnets, a motor stator and pump housing having double-helical volutes. To investigate the characteristics of the HFP, computational fluid dynamics analysis was performed.

View Article and Find Full Text PDF

Development have been achieved of a new blood pump for next generation Percutaneous Cardio-Pulmonary Support (PCPS) system and a novel surface coating method for silicone membrane hollow fiber by physical adsorption using a copolymer composed of a 2-Methacryloyloxyethyl phosphorylcholine (MPC) unit and a hydrophobic unit. The new blood pump, named the Troidal Convolution Pump (TCP), is based on the principle of a cascade pump and perfused 5 L/min and 350 mmHg at 2450 rpm. The novel copolymer composed of 30% MPC unit and 3-(methacryloyloxy) propyltris (trimethylsiloxy) silane (MPTSSi) unit (PMMSi30) was the most suitable molecular design on a silicone surface.

View Article and Find Full Text PDF

The helical flow pump (HFP) is newly developed blood pomp for total artificial heart (TAH). HFP can work with lower rotational speed than axial and centrifugal blood pump. It can be seen reasonable feature to generate pulsatile flow because high response performance can be realized.

View Article and Find Full Text PDF

To realize a total artificial heart (TAH) with high performance, high durability, good anatomical fitting, and good blood compatibility, the helical flow TAH (HFTAH) has been developed with two helical flow pumps having hydrodynamic levitation impeller. The HFTAH was implanted in goats to investigate its anatomical fitting, blood compatibility, mechanical stability, control stability, and so on. The size of the HFTAH was designed to be 80 mm in diameter and 84 mm wide.

View Article and Find Full Text PDF

We have developed a hydrodynamically levitated centrifugal blood pump with a semi-open impeller for long-term circulatory assist. The pump uses hydrodynamic bearings to enhance durability and reliability without additional displacement-sensors or control circuits. However, a narrow bearing gap of the pump has a potential for hemolysis.

View Article and Find Full Text PDF

The helical flow pump (HFP) is a novel rotary blood pump invented for developing a total artificial heart (TAH). The HFP with a hydrodynamic levitation impeller, which consists of a multi-vane impeller involving rotor magnets, stator coils at the core position, and double helical-volute pump housing, was developed. Between the stator and impeller, a hydrodynamic bearing is formed.

View Article and Find Full Text PDF

Animal experiments using a total artificial heart in a goat are not easy to perform. The fourth model of the undulation pump total artificial heart (UPTAH4), which was designed to perform a long-term physiological experiment including pulsatile and nonpulsatile TAH operations with a conductance- and arterial pressure-based control method named 1/R control, was implanted in 31 goats weighing 38.5 to 60.

View Article and Find Full Text PDF

Significant progress in the development of implantable ventricular assist devices using continuous-flow blood pumps has been made recently. However, a control method has not been established. The blood pressure in the inflow cannula (inlet pressure) is one of the candidates for performing an adequate control.

View Article and Find Full Text PDF

To facilitate research and development (R&D) and to expedite the review processes of medical devices, the Ministry of Health, Labor and Welfare (MHLW) and the Ministry of Economy, Trade and Industry (METI) founded a joint committee to establish guidance for newly emerging technology. From 2005 to 2007, two working groups held discussions on ventricular assist devices and total artificial hearts, including out-of-hospital programs, based on previous guidance documents and standards. Based on this discussion, the METI published the R&D Guidelines for innovative artificial hearts in 2007, and in 2008 the MHLW published a Notification by Director regarding the evaluation criteria for emerging technology.

View Article and Find Full Text PDF

The rapid progress of artificial heart and circulatory support devices enables us to apply them to severe heart failure patients. Many types of circulatory support devices have been developed in the United States, Europe, and Japan. This situation urged the establishment of an International Organization for Standardization (ISO) Standard for the circulatory support devices.

View Article and Find Full Text PDF

We developed an in vivo insert molding technique to form tissue-derived biomaterials into the desired shape, and with sufficient strength and durability, for use in artificial organs. Molds of acrylic resin with inserted velour cloth were implanted under the skin of goats to form a circular leaflet for a jellyfish valve. The valve leaflets were successfully produced in the molds after 17-60 days.

View Article and Find Full Text PDF

It is well known that the baroreflex system is one of the most important indicators of the pathophysiology in hypertensive patients. We can check the sensitivity of the baroreflex by observing heart rate (HR) responses; however, there is no simple diagnostic method to measure the arterial behavior in the baroreflex system. Presently, we report the development of a method and associated hardware that enables the diagnosis of baroreflex sensitivity by measuring the responses of both the heart and the artery.

View Article and Find Full Text PDF

The aim of this study was to examine the baroreflex sensitivity (BRS), which involves the autonomic nervous system, in a goat with a chronically implanted undulation pump ventricular assist device (UPVAD). The UPVAD involved transforming the rotation of a brushless DC motor into an undulating motion by a disc attached via a special linking mechanism, and a jellyfish valve in the outflow cannula to prevent diastolic backflow. The pump was implanted into the thoracic cavity of a goat by a left thoracotomy, and the inflow and outflow cannulae were sutured to the apex of the left ventricle and to the descending aorta, respectively.

View Article and Find Full Text PDF

A total artificial heart (TAH) using continuous flow pumps is promising for size reduction of the device; however, the role of pulsatility in TAHs has been a subject of great debate. Additionally, it is unclear whether, in a nonpulsatile TAH, a physiological control method such as 1/R control can keep the experimental animal in good condition. To realize a nonpulsatile TAH with 1/R control, the artificial valves were removed from undulation pump total artificial hearts (UPTAHs), which can produce both pulsatile and nonpulsatile flows using a single device.

View Article and Find Full Text PDF

The authors have been developing an artificial myocardium, which is capable of supporting natural contractile function from the outside of the ventricle. The system was originally designed by using sophisticated covalent shape memory alloy fibres, and the surface did not implicate blood compatibility. The purpose of our study on the development of artificial myocardium was to achieve the assistance of myocardial functional reproduction by the integrative small mechanical elements without sensors, so that the effective circulatory support could be accomplished.

View Article and Find Full Text PDF

A series of guidelines for development and assessment of next-generation medical devices has been drafted under an interagency collaborative project by the Ministry of Health, Labor and Welfare and the Ministry of Economy, Trade and Industry. The working group for assessment guidelines of next-generation artificial hearts reviewed the trend in the prevalence of heart failure and examined the potential usefulness of such devices in Japan and in other countries as a fundamental part of the process of establishing appropriate guidelines. At present, more than 23 million people suffer from heart failure in developed countries, including Japan.

View Article and Find Full Text PDF

The authors have been developing a mechano-electric artificial myocardial assist system (artificial myocardium) which is capable of supporting natural contractile functions from the outside of the ventricle without blood contacting surface. In this study, a nano-tech covalent type shape memory alloy fibre (Biometal, Toki Corp, Japan) was employed and the parallel-link structured myocardial assist device was developed. And basic characteristics of the system were examined in a mechanical circulatory system as well as in animal experiments using goats.

View Article and Find Full Text PDF

Vessel pulsation is presumably a key physiological function for the optimal supply of peripheral tissues and vital organs by oxygen and nutrients. The absence of pulsatility might impair the peripheral perfusion stability and trigger microvascular dysfunction of vital organs. The main purpose of this study was to investigate the influence of non-pulsatile flow on the microcirculation in experimental goat with implanted undulation pump total artificial heart (UPTAH).

View Article and Find Full Text PDF

We have developed internal battery systems for driving an undulation pump ventricular assist device using two kinds of lithium ion rechargeable batteries. The lithium ion rechargeable batteries have high energy density, long life, and no memory effect; however, rise in temperature of the lithium ion rechargeable battery is a critical issue. Evaluation of temperature rise by means of numerical estimation is required to develop an internal battery system.

View Article and Find Full Text PDF

The development of mechanical circulatory support devices at the University of Tokyo has focused on developing a small total artificial heart (TAH) since achieving 532 days of survival of an animal with a paracorporial pneumatically driven TAH. The undulation pump was invented to meet this purpose. The undulation pump total artificial heart (UPTAH) is an implantable TAH that uses an undulation pump.

View Article and Find Full Text PDF