Publications by authors named "Ilaria Cataneo"

Objective: Our aim was to assess diagnostic accuracy in the prediction of small for gestational age (SGA <10th centile) and fetal growth restricted (FGR) (SGA <3rd centile) fetuses using three different sonographic methods in pregnancies at increased risk of fetal growth restriction: 1) fetal abdominal circumference (AC) z-scores, 2) estimated fetal weight (EFW) z-scores according to postnatal reference standard; 3) EFW z-scores according to a prenatal reference standard.

Methods: Singleton pregnancies at increased risk of fetal growth restriction seen in two university hospitals between 2014 and 2015 were studied retrospectively. EFW was calculated using formulas proposed by the INTERGROWTH-21st project and Hadlock; data derived from publications by the INTEGROWTH-twenty-first century project and Hadlock were used to calculate z-scores (AC and EFW).

View Article and Find Full Text PDF

The new coronavirus emergency spread to Italy when little was known about the infection's impact on mothers and newborns. This study aims to describe the extent to which clinical practice has protected childbirth physiology and preserved the mother-child bond during the first wave of the pandemic in Italy. A national population-based prospective cohort study was performed enrolling women with confirmed SARS-CoV-2 infection admitted for childbirth to any Italian hospital from 25 February to 31 July 2020.

View Article and Find Full Text PDF
Article Synopsis
  • Insufficient information during pregnancy can skew perceptions of risk related to maternal infections that may be passed to the fetus, potentially leading to unnecessary anxiety or decisions to terminate pregnancy.
  • The study involved 185 pregnant women with infections, assessing the impact of expert counseling on their perception of risks and their willingness to terminate the pregnancy, using questionnaires pre- and post-counseling.
  • Results showed a significant reduction in maternal anxiety about the baby's health after counseling, highlighting the importance of clear, expert guidance in managing concerns about infection risks.
View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the impact of SARS-CoV-2 infection during pregnancy, focusing on maternal and fetal health in high-risk versus low-risk pregnancies.
  • Conducted across 76 centers worldwide, the research looked at data from 887 infected singleton pregnancies, assessing outcomes like severe maternal morbidity and perinatal complications.
  • Results indicate that high-risk pregnancies have a significantly higher likelihood of adverse maternal outcomes and hospital admissions compared to low-risk pregnancies.
View Article and Find Full Text PDF

Background: Malpositions and deflexed cephalic malpresentations are well recognized causes of dysfunctional labor, may result in fetal and maternal complications, and are diagnosed more precisely with an ultrasound examination than with a digital examination.

Objective: This study aimed to assess the incidence of malpositions and deflexed cephalic malpresentations at the beginning of the second stage of labor and to evaluate the role of the sonographic diagnosis of deflexion in the prediction of the mode of delivery.

Study Design: Women in labor with a singleton pregnancy at term with fetuses in a cephalic presentation at 10 cm of cervical dilatation were prospectively examined.

View Article and Find Full Text PDF

Objectives To evaluate the strength of association between maternal and pregnancy characteristics and the risk of adverse perinatal outcomes in pregnancies with laboratory confirmed COVID-19. Methods Secondary analysis of a multinational, cohort study on all consecutive pregnant women with laboratory-confirmed COVID-19 from February 1, 2020 to April 30, 2020 from 73 centers from 22 different countries. A confirmed case of COVID-19 was defined as a positive result on real-time reverse-transcriptase-polymerase-chain-reaction (RT-PCR) assay of nasal and pharyngeal swab specimens.

View Article and Find Full Text PDF

Background: Intrapartum ultrasound scanning has been proposed as an ancillary tool in the decision-making process of instrumental vaginal delivery.

Objective: The purpose of this study was to evaluate the correlation between the sonographic visualization with a transperineal scan of the fetal occiput or forehead distal to the pubic symphysis with anterior or posterior presentation, respectively (fetal occiput or forehead sign), and the outcome of a vacuum delivery.

Study Design: We conducted a retrospective cohort study of patients who underwent a vacuum application in our hospital from 2011-2017, excluding outlet applications.

View Article and Find Full Text PDF

Background: Paravaginal hematoma can be a severe postpartum complication. Diagnosis is challenging because signs and symptoms are often nonspecific. Most of the available literature about diagnostic imaging in these cases focuses on the use of computed tomography or magnetic resonance imaging, and there are very limited data on the use of sonography.

View Article and Find Full Text PDF

Purpose: To determine reference values for umbilical Doppler pulsatility index in fetuses with isolated two-vessel cord and to compare these values with standard umbilical Doppler pulsatility index curves from 23 to 40 gestational weeks.

Methods: A retrospective longitudinal cohort study was conducted between January 2014 and December 2017 in a tertiary referral hospital and included 62 pregnant women with isolated single umbilical artery (two-vessel cord) and 174 measurements. Only uncomplicated term pregnancies were included.

View Article and Find Full Text PDF

During the last decade, there has been a huge advancement in the use of transperineal ultrasound (TPU) in the field of obstetrics and gynecology. Its main applications in obstetrics include the monitoring of fetal progression in labor and recently the assessment of maternal pelvic dimensions, whereas in gynecology, TPU is at present widely used for the evaluation of the female pelvic floor, opening new boundaries for the assessment of pelvic floor disorders. The association of volumetric three-dimensional techniques has largely contributed to the remarkable progress that has occurred in the use of TPU.

View Article and Find Full Text PDF

Objective: To evaluate the ability of intrapartum ultrasound to differentiate occipitoposterior (OP) rotation with normal flexion of the head from deflexion, to compare the accuracy of ultrasound with the digital examination, and to assess the outcome of labor according to the type of presentation.

Patients And Methods: A retrospective study of patients with abnormal labor because of either prolongation and/or abnormal cardiotocography and OP rotation who underwent intrapartum sonography.

Results: Normal flexion was inferred in 36/42 cases by a longitudinal sonographic view of the fetal face demonstrating the chin approaching the chest.

View Article and Find Full Text PDF

Objectives: To compare the accuracy of the INTERGROWTH-21st (IG-21) with the Italian Society of Ultrasound in Obstetrics and Gynecology (SIEOG) abdominal circumference (AC) standards in the detection of small-for-gestational-age (SGA) fetuses in a high-risk population.

Material And Methods: Our study included all pregnant patients with an increased risk of placental insufficiency that were seen in two Italian university hospitals between 2014 and 2015. The accuracy of IG-21 and SIEOG AC standards in the detection of SGA neonates was analyzed by means of the area under the receiver operating characteristic curve (ROC-AUC) at 4 gestational age intervals (24-27, 28-31, 32-35, >35 weeks).

View Article and Find Full Text PDF

Objectives: To assess the reliability of a new three-dimensional (3D) ultrasound technique for the measurement of the subpubic arch angle (SPA) and the agreement between two contrast-enhancing 3D ultrasound techniques.

Methods: We acquired two static 3D transperineal volumes from 72 nulliparous women using two ultrasound machines equipped with two different 3D contrast enhancement and linear reconstruction softwares: 1. Oblique View Extended Imaging with HD-Volume Imaging (OVIX-HDVI™), Samsung; 2.

View Article and Find Full Text PDF