In this study, we investigated the influence of quasi-one-dimensional (Quasi-1D) characteristics on the source and drain contact resistances within vertical nanowire (NW) field-effect transistors (FETs) of diminutive diameter. The top contact of the NW is segregated into two distinct regions: the first encompassing the upper surface, designated as the axial contact, and the second encircling the side surface, known as the radial contact, which is formed during the top-contact metal deposition process. Quantum confinement effects, prominent within Quasi-1D NWs, exert significant constraints on radial transport, consequently inducing a noticeable impact on contact resistance.
View Article and Find Full Text PDFMicromachines (Basel)
January 2022
Effects of carbon implantation (C-imp) on the contact characteristics of Ti/Ge contact were investigated. The C-imp into Ti/Ge system was developed to reduce severe Fermi-level pinning (FLP) and to improve the thermal stability of Ti/Ge contact. The current density ()-voltage () characteristics showed that the rectifying behavior of Ti/Ge contact into an Ohmic-like behavior with C-imp.
View Article and Find Full Text PDFWe present the fabrication and electrical characteristics of nanonet-channel (NET) low-temperature polysilicon channel (LTPS) thin-film transistors (TFTs) using a nanosphere-assisted patterning (NAP) technique. The NAP technique is introduced to form a nanonet-channel instead of the electron beam lithography (EBL) or conventional photolithography method. The size and space of the holes in the nanonet structure are well controlled by oxygen plasma treatment and a metal lift-off process.
View Article and Find Full Text PDFBackground/aims: The aim of this study was to evaluate the efficacy of high definition (HD) i-SCAN for colorectal polyp detection in screening colonoscopy.
Methods: We retrospectively analyzed the records of 501 patients who had undergone screening colonoscopy performed by three endoscopists with either HD i-SCAN (n=149) or standard white light (n=352) from January 2, 2014 through June 30, 2014. Patient information and inter-endoscopist variation as well as polyp number, endoscopic findings, and pathologic characteristics were reviewed.
A 29-year-old pregnant woman with recurrent pericardial effusion and a cardiac tumor, diagnosed as an angiosarcoma, was treated with surgical resection of the tumor followed by radiotherapy. Immediately after completion of radiotherapy, she developed bilateral breast masses, which were also confirmed as angiosarcomas. We thought this might be the first case of bilateral angiosarcoma of the breast metastasizing to heart mimicking a primary cardiac angiosarcoma, although we could not conclude with certainty that angiosarcoma of the heart was not the primary site.
View Article and Find Full Text PDF