Publications by authors named "Igor Chernushevich"

We report the progress on an electron-activated dissociation (EAD) device coupled to a quadrupole TOF mass spectrometer (QqTOF MS) developed in our group. This device features a new electron beam optics design allowing up to 100 times stronger electron currents in the reaction cell. The electron beam current reached the space-charge limit of 0.

View Article and Find Full Text PDF

Orthogonal injection time-of-flight (orthoTOF) mass spectrometry (MS) is the most prevalent form of TOFMS, owing to its greater control over incoming ion energy, the ability to correct for aberrations in incoming ion velocity and position, and its ability to provide an entire mass spectrum within a single scan. However, the duty cycle of orthoTOFMS is low compared with scanning analyzers, which can have 100% duty cycle when measuring a single type of ion. Typical duty cycles for orthoTOFMS range from 1% to 30%, depending on instrument geometry.

View Article and Find Full Text PDF

Differential mobility spectrometry (DMS) is an ion mobility technique that has been adopted chiefly as a pre-filter for small- to medium-sized analytes (<1 000 Da). With the exception of a handful of studies that employ an analogue of DMS-field asymmetric waveform ion mobility spectroscopy (FAIMS)-the application of DMS to intact biomacromolecules remains largely unexplored. In this work, we employ DMS combined with gas-phase hydrogen deuterium exchange (DMS-HDX) to probe the gas-phase conformations generated from proteins that were initially folded, partially-folded, and unfolded in solution.

View Article and Find Full Text PDF

Although TOF analyzers with orthogonal ion injection provide the whole spectrum without scanning, their duty cycle is low compared with scanning analyzers in single ion monitoring mode. Typical duty cycle is in the range of 5% to 30% depending on the instrument geometry and ion m/z value. We present here a novel trapping/releasing setup, which offers the duty cycle near 100% over a wide range.

View Article and Find Full Text PDF

Mass spectrometry and gas phase ion mobility [gas phase electrophoretic macromolecule analyzer (GEMMA)] with electrospray ionization were used to characterize the structure of the noncovalent 28-subunit 20S proteasome from Methanosarcina thermophila and rabbit. ESI-MS measurements with a quadrupole time-of-flight analyzer of the 192 kDa alpha7-ring and the intact 690 kDa alpha7beta7beta7alpha7 are consistent with their expected stoichiometries. Collisionally activated dissociation of the 20S gas phase complex yields loss of individual alpha-subunits only, and it is generally consistent with the known alpha7beta7beta7alpha7 architecture.

View Article and Find Full Text PDF

Collisional cooling of ions in the rf-only multipole guides has become a method of choice for coupling electrospray sources to various mass analyzers. Normally parameters of such ion guides (length, pressure) provide enough thermalization and focusing for ions in a wide mass range. Noncovalent complexes, however, have more compact conformations than denatured biomolecules of similar mass and, therefore may not be transmitted efficiently through standard ion guides, as demonstrated by theoretical analysis, simulations, and experiments.

View Article and Find Full Text PDF

A hybrid quadrupole time-of-flight mass spectrometer featured with ion trapping capabilities was employed for quantitative profiling of total extracts of endogenous phospholipids. Simultaneous acquisition of precursor ion spectra of multiple fragment ions allowed detection of major classes of phospholipids in a single experiment. Relative changes in their concentration were monitored using a mixture of isotopically labeled endogenous lipids as a comprehensive internal standard.

View Article and Find Full Text PDF

Sorghum (Sorghum bicolor) was infected by a mechanically transmissible, flexuous, rod-shaped virus. Antiserum made against the purified virus reacted specifically in enzyme-linked immunosorbent assay to the virus and to the potexvirus foxtail mosaic virus (FoMV), indicating that the sorghum virus was an isolate of FoMV. Comparison of the sorghum isolate (H93) to FoMV PV 139 showed that H93 differed biologically by causing severe symptoms in sorghum, not readily infecting certain barley lines, and causing only faint symptoms in barley.

View Article and Find Full Text PDF