Background: The noninferiority of left ventricular pacing alone (LVp) compared with biventricular pacing (BIV) has not been yet definitely documented. In this study, we reviewed all the original echocardiographic measures of the Biventricular versus Left Univentricular Pacing with ICD Back-up in Heart Failure Patients (B-LEFT HF) trial in order to investigate mechanisms underlying LV remodelling with both pacing modalities.
Methods: Patients with New York Heart Association functional class (NYHA) III or IV despite optimal medical therapy, LVEF 35% or less, left ventricular end-diastolic diameter (LVEDD) more than 55 mm, QRS duration at least 130 ms were randomized to BIV or LVp for 6 months.
We present the first reported case of extraction of a ventricular lead placed in the left bundle branch area with a double-loop design snare via the femoral approach without any complication. It was a 4-month-old lead whose extraction was not possible only with a conventional stylet via an implant vein approach, so we want to show that complete procedural success is possible.
View Article and Find Full Text PDFEfficacy and safety of dronedarone was shown in the ATHENA trial for paroxysmal or persistent atrial fibrillation (AF) patients. Further trials revealed safety concerns in patients with heart failure and permanent AF. This review summarizes insights from recent real-world studies and meta-analyses, including reports on efficacy, with focus on liver safety, mortality risk in patients with paroxysmal/persistent AF, and interactions of dronedarone with direct oral anticoagulants.
View Article and Find Full Text PDFBackground: In the ICD Sports Safety Registry, death, arrhythmia- or shock-related physical injury did not occur in athletes who continue competitive sports after implantable cardioverter-defibrillator (ICD) implantation. However, data from non-competitive ICD recipients is lacking. This report describes arrhythmic events and lead performance in intensive recreational athletes with ICDs enrolled in the European recreational arm of the Registry, and compares their outcome with those of the competitive athletes in the Registry.
View Article and Find Full Text PDFPurpose: Comparisons of the efficacy of dual- vs. single-chamber implantable cardioverter defibrillators (ICDs) in preventing inappropriate shocks have had contradictory results. We investigated whether dual-chamber devices have a lower risk of inappropriate shocks and the specific role of supraventricular tachycardia (SVT) discriminators.
View Article and Find Full Text PDFGlob Cardiol Sci Pract
August 2018
Sudden cardiac death (SCD) is the most devastating complication in hypertrophic cardiomyopathy (HCM). The implantable cardioverter-defibrillator (ICD) has proven to be effective in SCD prevention in several clinical scenarios. In HCM population, it has demonstrated to successfully abort life-threatening ventricular arrhythmias despite the extreme morphology characteristic of HCM, often with massive degrees of left ventricular hypertrophy and/or LV outflow tract obstruction.
View Article and Find Full Text PDFInt J Cardiol
January 2019
Background: Concerns about the efficacy of prophylactic ICD in non-ischemic cardiomyopathy (NICM) heart failure (HF) patients are still present. We aimed to assess whether survival and arrhythmic risk were different among ischemic cardiomyopathy (ICM) and NICM ICD-only patients, along with specific predictors for mortality.
Methods: HF patients undergoing ICD-only implant were extracted from the nationwide multicenter UMBRELLA registry.
Clin Res Cardiol
July 2018
Background: Hypertension is an important, modifiable risk factor for the development of atrial fibrillation (AF). Even after pulmonary vein isolation (PVI), 20-40% experience recurrent AF. Animal studies have shown that renal denervation (RDN) reduces AF inducibility.
View Article and Find Full Text PDFThe aim of this study was to identify the candidates for natural killer (NK) testing and to define the best methodology. For this purpose a prospective study was performed on 73 women with repeated implantation failure (RIF). RIF was considered to exist in patients not achieving clinical pregnancy after three transfers with at least one good-quality embryo.
View Article and Find Full Text PDFAtrial fibrillation (AF), is the most prevalent sustained arrhythmia in general population, affecting up to 10% in patients of advanced age. AF doubles overall mortality and increases up to 5-6 times the risk of stroke, which have the characteristic of being particularly harmful. The basis of treatment on AF are the rhythm or rate control and the prevention of thromboembolism.
View Article and Find Full Text PDFAim: Current guidelines recommend atrioventricular junction (AVJ) ablation in patients with atrial fibrillation (AF) treated with cardiac resynchronization therapy (CRT). Our study compared the CRT response of patients in sinus rhythm (SR) vs. AF.
View Article and Find Full Text PDFAs in other settings, in the field of clinical use of cardiac implantable electrical devices (CIEDs), the implementation, in various ways, of diagnosis-related groups (DRGs) has created new scenarios in most European healthcare systems. A DRG system is primarily a financial tool with the aim of promoting efficiency and improving utilization of resources. However, there are a variety of ways in which this system is used for funding the activity of centres implanting CIEDs.
View Article and Find Full Text PDFPacing Clin Electrophysiol
October 2010
Background: Biventricular (BiV) stimulation is the preferred means of delivering cardiac resynchronization therapy (CRT), although left ventricular (LV)-only stimulation might be as safe and effective. B-LEFT HF is a prospective, multicenter, randomized, double-blind study aimed to examine whether LV-only is noninferior to BiV pacing regarding clinical and echocardiographic responses.
Methods: B-LEFT HF randomly assigned 176 CRT-D recipients, in New York Heart Association class III or IV, with an LV ejection fraction < or =35% and QRS > or =130 milliseconds, to a BiV (n = 90) versus LV (n = 86) stimulation group.
Background: The clinical benefit of cardiac resynchronization therapy (CRT) for patients with moderate-to-severely symptomatic heart failure, left ventricular systolic dysfunction, and ventricular conduction delay is established. However, some patients do not demonstrate clinical improvement following CRT. It is unclear whether systematic optimization of the programmed atrioventricular (AV) delay improves the rate of clinical response.
View Article and Find Full Text PDFBull Environ Contam Toxicol
October 2009
Concentration of lead and cadmium has been analyzed in Bodianus scrofa and Mycteroperca fusca captured in the Canary Islands coast. Concentration of Pb ranged from 2.53 to 306.
View Article and Find Full Text PDFAims: Implantable cardioverter defibrillators (ICDs) are increasingly being used for treatment of ventricular tachycardia (VT)/fibrillation. Inappropriate therapy delivery remains the most frequent complication in patients with ICDs, resulting in psychological distress, proarrhythmia, and battery life reduction. We aim to determine if inappropriate therapies could be reduced by using a morphology discrimination criterion.
View Article and Find Full Text PDF