Task Group (TG) 314 of the American Association of Physicists in Medicine (AAPM) was charged to develop guidance for recovering from fault states in radiation therapy, specifically regarding the delivery of photon or electron beams using a linear accelerator (linac) including ancillary systems. The fault conditions addressed may involve software, hardware, or a combination of causes. The report provides detailed recommendations for the proactive steps to be taken before a fault, the actions to be taken at the time of a fault, and the safety steps before returning a linac to clinical service, as well as the activities that device manufacturers and standard organizations can do to prevent and resolve the faults.
View Article and Find Full Text PDFPurpose: To determine whether addition of external beam radiation therapy (EBRT) to brachytherapy (BT) (COMBO) compared with BT alone would improve 5-year freedom from progression (FFP) in intermediate-risk prostate cancer.
Methods: Men with prostate cancer stage cT1c-T2bN0M0, Gleason Score (GS) 2-6 and prostate-specific antigen (PSA) 10-20 or GS 7, and PSA < 10 were eligible. The COMBO arm was EBRT (45 Gy in 25 fractions) to prostate and seminal vesicles followed by BT prostate boost (110 Gy if 125-Iodine, 100 Gy if 103-Pd).
The International Organization for Medical Physics (IOMP) is the world's largest professional organization in the field of medical physics and has official non-governmental organization status with the World Health Organization (WHO) and the International Atomic Energy Agency (IAEA). IOMP is charged with a mission to advance medical physics practice worldwide by disseminating scientific and technical information, fostering the educational and professional development of medical physics and promoting the highest quality medical services for patients. IOMP's activities are directed towards the promotion of medical physics globally, improving patient care, and contributing to the benefit of healthcare to the society.
View Article and Find Full Text PDFHealth Technol (Berl)
April 2022
As a profession, medical physics combines an advanced understanding of physics and math with knowledge of biology, anatomy and physiology. Consequently, rigorous education and training is required to assure that medical physicists have the requisite fundamental knowledge, specialized technical skills, and clinical understanding to contribute to the medical care of patients safely. There is, therefore, an interest in standardizing the educational pathways and in developing mechanisms to assure that competency is achieved and maintained.
View Article and Find Full Text PDFRecent publications show that some patients receive high cumulative radiation doses from recurrent CT examinations. Most of these patients had a diagnosis of malignancy, meaning that there was a likelihood that they would receive radiation therapy, possibly with image guidance. Patients receiving X-ray-based image-guided radiation therapy (IGRT) receive even more imaging dose, including to volumes of tissue outside the tumor target volume.
View Article and Find Full Text PDFRadiation therapy in the presence of a strong magnetic field is known to cause regions of enhanced and reduced dose at interfaces of materials with varying densities, in a phenomenon known as the electron return effect (ERE). In this study, a novel low-density gel dosimeter was developed to simulate lung tissue and was used to measure the ERE at the lung-soft tissue interface. Low-density gel dosimeters were developed with Fricke xylenol orange gelatin (FXG) and ferrous oxide xylenol orange (FOX) gels mixed with polystyrene foam beads of various sizes.
View Article and Find Full Text PDFRadiat Meas
September 2018
Purpose: To characterize the response of plastic scintillation detectors (PSDs) to high-energy photon radiation as a function of magnetic field strength.
Materials And Methods: PSDs were placed inside a plastic phantom held at the center point between 2 magnets and irradiated using a 6-MV photon beam from a linear accelerator. The magnetic field was varied from 0 T to 1.
Intrafraction motion (i.e. motion occurring during a treatment session) can play a pivotal role in the success of abdominal and thoracic radiation therapy.
View Article and Find Full Text PDFPurpose: We aim to determine the feasibility and dosimetric benefits of a novel MRI-guided IMRT dose-adaption strategy for human papillomavirus positive (HPV+) oropharyngeal squamous cell carcinoma (OPC).
Materials/methods: Patients with locally advanced HPV+ OPC underwent pre-treatment and in-treatment MRIs every two weeks using RT immobilization setup. For each patient, two IMRT plans were created (i.
This analysis estimated secondary cancer risks after volumetric modulated arc therapy (VMAT) and compared those risks to the risks associated with other modalities of head-and-neck (H&N) radiotherapy. Images of H&N anthropomorphic phantom were acquired with a computed tomography scanner and exported via digital imaging and communications in medicine (DICOM) standards to a treatment planning system. Treatment plans were performed using a VMAT dual-arc technique, a nine-field intensity-modulated radiation therapy (IMRT) technique, and a four-field three-dimensional conformal therapy (3DCRT) technique.
View Article and Find Full Text PDFThe introduction of image guidance in radiation therapy and its subsequent innovations have revolutionised the delivery of cancer treatment. Modern imaging systems can supplement and often replace the historical practice of relying on external landmarks and laser alignment systems. Rather than depending on markings on the patient's skin, image-guided radiation therapy (IGRT), using techniques such as computed tomography (CT), cone beam CT, MV on-board imaging (OBI), and kV OBI, allows the patient to be positioned based on the internal anatomy.
View Article and Find Full Text PDFWe developed a novel technique to study the impact of geometric distortion of magnetic resonance imaging (MRI) on intensity-modulated radiation therapy treatment planning. The measured 3D datasets of residual geometric distortion (a 1.5 T MRI component of an MRI linear accelerator system) was fitted with a second-order polynomial model to map the spatial dependence of geometric distortions.
View Article and Find Full Text PDFThe integration of magnetic resonance imaging (MRI) with linear accelerators (linac) has enabled the use of 3D MR-visible gel dosimeters for real-time verification of volumetric dose distributions. Several iron-based radiochromic 3D gels were created in-house then imaged and irradiated in a pre-clinical 1.5 T-7 MV MR-Linac.
View Article and Find Full Text PDFPurpose: To assess the image quality, scatter, and leakage radiation of an integrated magnetic resonance linear accelerator (MR-LINAC or MRL) system.
Methods: A large American College of Radiology (ACR) magnetic resonance imaging (MRI) accreditation phantom was used to evaluate the MRI capabilities of the integrated MRL system compared with those of other diagnostic MRI systems. Multiple sets of T1 and T2/PD images were acquired with the linear accelerator positioned at various angles and with the radiation beam on and off.
As medical technology evolves and patient needs increase, the need for well-trained and highly professional medical physicists (MPs) becomes even more urgent. The roles and responsibilities of MPs in various departments within the hospital are diverse and demanding. It is obvious that training, continuing education and professional development of MPs have become essential.
View Article and Find Full Text PDFPhototherapy treatment using ultraviolet (UV) A and B light sources has long existed as a treatment option for various skin conditions. Quality control for phototherapy treatment recommended by the British Association of Dermatologists and British Photodermatology Group generally focused on instrumentation-based dosimetry measurements. The purpose of this study was to present an alternative, easily prepared dosimeter system for the measurement of UV dose and as a simple quality assurance technique for phototherapy treatments.
View Article and Find Full Text PDFPurpose: The education and training landscape has been profoundly reshaped by the ABR 2012/2014 initiative and the MedPhys Match. This work quantifies these changes and summarizes available reports, surveys, and statistics on education and training.
Methods: We evaluate data from CAMPEP-accredited program websites, annual CAMPEP graduate and residency program reports, and surveys on the MedPhys Match and Professional Doctorate degree (DMP).
Purpose: More than 6,500 megavoltage teletherapy units are needed worldwide, many in low-resource settings. Cobalt-60 units or linear accelerators (linacs) can fill this need. We have evaluated machine performance on the basis of patient throughput to provide insight into machine viability under various conditions in such a way that conclusions can be generalized to a vast array of clinical scenarios.
View Article and Find Full Text PDFBackground And Purpose: The strong magnetic field of integrated magnetic resonance imaging (MRI) and radiation treatment systems influences secondary electrons resulting in changes in dose deposition in three dimensions. To fill the need for volumetric dose quality assurance, we investigated the effects of strong magnetic fields on 3D dosimeters for MR-image-guided radiation therapy (MR-IGRT) applications.
Material And Methods: There are currently three main categories of 3D dosimeters, and the following were used in this study: radiochromic plastic (PRESAGE®), radiochromic gel (FOX), and polymer gel (BANG™).
Since the publication of the 2004 update to the American Association of Physicists in Medicine (AAPM) Task Group No. 43 Report (TG-43U1) and its 2007 supplement (TG-43U1S1), several new low-energy photon-emitting brachytherapy sources have become available. Many of these sources have satisfied the AAPM prerequisites for routine clinical purposes and are posted on the Brachytherapy Source Registry managed jointly by the AAPM and the Imaging and Radiation Oncology Core Houston Quality Assurance Center (IROC Houston).
View Article and Find Full Text PDFPurpose: The Imaging and Radiation Oncology Core Houston (IROC-H) (formerly the Radiological Physics Center) has reported varying levels of agreement in their anthropomorphic phantom audits. There is reason to believe one source of error in this observed disagreement is the accuracy of the dose calculation algorithms and heterogeneity corrections used. To audit this component of the radiotherapy treatment process, an independent dose calculation tool is needed.
View Article and Find Full Text PDFAdvances in image-guided radiotherapy (RT) have allowed for dose escalation and more precise radiation treatment delivery. Each decade brings new imaging technologies to help improve RT patient setup. Currently, the most frequently used method of three-dimensional pre-treatment image verification is performed with cone beam CT.
View Article and Find Full Text PDF