Objective: To describe a simple therapeutic intervention for persistent congestion in an advanced heart failure patient using a continuous intravenous furosemide infusion in the home setting with a non-powered elastomeric pump that can be managed by the patient.
Key Steps: Patient selected as a known intravenous furosemide responder with a supportive home environment. Shared care decision making with patient, cardiologist, heart failure nurse practitioner, palliative care physician, and general practitioner.
An increase in coronavirus disease (COVID-19) infections prompted Level 4 lockdown throughout New Zealand from 25 March 2020. We have investigated trends in coronary and electrophysiology (EP) procedures before and during this lockdown. The number of acute procedures for ST elevation myocardial infarction remained stable.
View Article and Find Full Text PDFObjectives: The ASD2 (Acute Extravascular Defibrillation, Pacing, and Electrogram) study evaluated the ability to adequately sense, pace, and defibrillate patients with a novel implantable cardioverter-defibrillator (ICD) lead implanted in the substernal space.
Background: Subcutaneous ICDs are an alternative to a transvenous defibrillator system when transvenous implantation is not possible or desired. An alternative extravascular system placing a lead under the sternum has the potential to reduce defibrillation energy and the ability to deliver pacing therapies.
Background: Isolated cardiac arrhythmia due to a variant in CACNA1C is of recent knowledge. Most reports have been of singleton cases or of quite small families, and estimates of penetrance and expressivity have been difficult to obtain. We here describe a large pedigree, from which such estimates have been calculated.
View Article and Find Full Text PDFCirc Arrhythm Electrophysiol
February 2018
Background: Catheter ablation for atrial fibrillation has potential to cause esophageal thermal injury. Esophageal temperature monitoring during ablation is commonly used; however, it has not eliminated thermal injuries, possibly because conventional sensors have poor spatial sampling and response characteristics. To enhance understanding of temperature dynamics that may underlie esophageal injury, we tested a high-resolution, intrabody, infrared thermography catheter to continuously image esophageal temperatures during ablation.
View Article and Find Full Text PDFClin Exp Pharmacol Physiol
September 2015
Background: The recent advent of subcutaneous implantable cardioverter defibrillators (S-ICDs) has provided investigators with a safe and effective new therapy in patients at risk of sudden cardiac death. At present, no data are available with regard to the longevity of these new devices. This study evaluated the longevity of the S-ICD system.
View Article and Find Full Text PDFObjectives: The purpose of this study is to investigate the effects of urocortin-2 as adjunct therapy in acute decompensated heart failure (ADHF).
Background: Urocortin-2 produced favorable integrated effects in experimental heart failure but there are no equivalent human data. We describe the first therapeutic study of urocortin-2 infusion in ADHF.
Background: We hypothesized that left atrial pressure (LAP) obtained by a permanent implantable sensor is sensitive to changes in cardiac resynchronization therapy (CRT) settings and could guide CRT optimization to improve the response rate. We investigated the effect of CRT optimization on LAP and its waveform parameters in ambulant heart failure (HF) patients.
Methods: CRT optimization was performed in eight ambulant HF patients, using echocardiography as reference.
A left atrial pressure (LAP) monitoring system was developed for guiding the management of patients with heart failure. The LAP sensor is implanted into the left atrium via transseptal catheterization and affixed to the interatrial septum by nitinol anchors. The long-term safety of permanent implantation of the LAP sensor in patients was evaluated based on the comparative pathology in animals.
View Article and Find Full Text PDFBackground: Many papers evaluating high sensitivity troponin assays make the diagnosis of myocardial infarction based on conventional troponin assays in clinical use at the time of recruitment. Such analyses often do not show superiority of high sensitivity assays compared with contemporary assays meeting precision guidelines.
Methods: Three hundred and twenty-two patients presenting to the emergency department between November 2006 and April 2007 for evaluation for acute coronary syndrome had serial (0 h and >6 h) bloods taken to compare troponin assays (Roche hsTnT, Abbott TnI, Roche TnT and Vitros TnI).
J Interv Card Electrophysiol
September 2012
The recent introduction of subcutaneous implantable cardioverter defibrillator (S-ICD) has raised attention about the potential of this technology for clinical use in daily clinical practice. We review the methods and results of the four studies conducted in humans for approval of this innovative technology for daily practice. Two studies using a temporary S-ICD system (acute human studies) were conducted to search for an appropriate lead configuration and energy requirements.
View Article and Find Full Text PDFBackground: There is little recent information regarding outcome and its determinants following cardioversion (CV) for atrial fibrillation (AF) or flutter. This study aims to help improve prediction of cardiac rhythm outcome following CV for AF.
Methods: Cardiac rhythm at 6 weeks and 12 months was documented following elective (EC; n=496) or immediate (IC; n=52) cardioversion for AF or atrial flutter in a single referral centre.
Aims: To report the long-term results following percutaneous pulmonary vein ablation (PVA) for atrial fibrillation (AF) at Christchurch Hospital.
Methods: A retrospective observational audit review of outcomes. The sample population included all patients identified as having undergone percutaneous radiofrequency ablation of multiple pulmonary veins at Christchurch Hospital, from the first procedure performed on 29 September 2001 until 15 December 2009.
Aims: To report the long-term results following surgical radiofrequency ablation (RFA) for atrial fibrillation as an adjunct to other cardiac surgery at Christchurch Hospital.
Methods: A retrospective observational audit review of outcomes. The sample population included all patients identified as having undergone surgical RFA for atrial fibrillation at Christchurch Hospital, between the first procedure performed on 2 July 2001 and 28 January 2009.
Objectives: This study sought to determine the accuracy of Doppler echocardiography and tissue Doppler imaging (TDI) measurements in detecting elevated left atrial pressure (LAP) in ambulant subjects with chronic heart failure using directly measured LAP as the reference.
Background: Echocardiographic indexes including the ratio of transmitral to annular early diastolic velocities (E/e') may identify raised invasively measured left ventricular filling pressures when tested in cross-sectional studies in some populations. The accuracy of these indexes when measured sequentially remains untested.
Background: It is often reported that clinical symptoms are useful in differentiating cardiac from non-cardiac syncope. Studies in the young are rare. This study was designed to capture the symptoms and signs reported by patients with cardiac syncope before the patients or their attending clinicians knew the final diagnosis.
View Article and Find Full Text PDFBackground: Previous studies have shown a risk of subsequent major adverse cardiovascular events (MACEs) in patients with suspected acute coronary syndromes (ACSs) and elevated cardiac troponin. The aim of this study was to compare prognostic utility of high-sensitivity troponin with contemporary troponin assays in such patients.
Methods: In total, 332 patients with suspected ACS were investigated between November 2006 and April 2007; all were followed for two years.
J Cardiovasc Transl Res
February 2011
We report the stability, accuracy, and development history of a new left atrial pressure (LAP) sensing system in ambulatory heart failure (HF) patients. A total of 84 patients with advanced HF underwent percutaneous transseptal implantation of the pressure sensor. Quarterly noninvasive calibration by modified Valsalva maneuver was achieved in all patients, and 96.
View Article and Find Full Text PDF