Background: Diffusion-weighted imaging (DWI) lesions have been linked to poor outcomes after intracerebral hemorrhage (ICH). We aimed to assess the impact of cerebral digital subtraction angiography (DSA) on the presence of DWI lesions in patients who underwent minimally invasive surgery (MIS) for ICH.
Methods: Retrospective chart review was performed on ICH patients treated with MIS in a single health system from 2015 to 2021.
Background: Spontaneous intracerebral hemorrhage (ICH) can rapidly result in cerebral herniation, leading to poor neurologic outcomes or mortality. To date, neither decompressive hemicraniectomy (DH) nor hematoma evacuation have been conclusively shown to improve outcomes for comatose ICH patients presenting with cerebral herniation, with these patients largely excluded from clinical trials. Here we present the outcomes of a series of patients presenting with ICH and radiographic herniation who underwent emergent minimally invasive (MIS) ICH evacuation.
View Article and Find Full Text PDFObjective: Neurosurgery residents face a learning curve at the beginning of residency. Virtual reality (VR) training may alleviate challenges through an accessible, reusable, anatomical model.
Methods: Medical students performed external ventricular drain placements in VR to characterize the learning curve from novice to proficient.
Background: Stroke represents the second highest disease burden worldwide. It is well documented that rapid stroke identification and treatment are associated with improved outcomes. In particular, prehospital stroke detection (PSD) devices have emerged as possible tools to facilitate more rapid and accurate stroke triage.
View Article and Find Full Text PDFStandard clinical care in neonatal and pediatric intensive-care units (NICUs and PICUs, respectively) involves continuous monitoring of vital signs with hard-wired devices that adhere to the skin and, in certain instances, can involve catheter-based pressure sensors inserted into the arteries. These systems entail risks of causing iatrogenic skin injuries, complicating clinical care and impeding skin-to-skin contact between parent and child. Here we present a wireless, non-invasive technology that not only offers measurement equivalency to existing clinical standards for heart rate, respiration rate, temperature and blood oxygenation, but also provides a range of important additional features, as supported by data from pilot clinical studies in both the NICU and PICU.
View Article and Find Full Text PDF