Publications by authors named "I Omana-Zapata"

Automated analysis of flow cytometry data can improve objectivity and reduce analysis time but has generally required work by software and algorithm experts. Here, we investigated the performance of BD ElastiGate™ Software (hereafter ElastiGate), which allows users to automate gating by selecting gated training files, then uses elastic image registration to gate new files. Three assays of increasing complexity were examined: TBNK, stem cell enumeration (SCE), and lymphoid screening tube (LST).

View Article and Find Full Text PDF

Clinical flow cytometry is a reliable methodology for whole blood cell phenotyping for different applications. The BD FACSLyric™ system comprises a flow cytometer available in different optical configurations, BD FACSuite™ Clinical software, and optional BD FACS™ Universal Loader. BD FACSuite Clinical software used with BD™ FC Beads and BD CS&T Beads enable universal setup for performance QC, instrument control, data acquisition/storage, online/offline data analysis, and instrument standardization.

View Article and Find Full Text PDF

Background: The BD FACSPresto system uses capillary and venous blood to measure CD4 absolute counts (CD4), %CD4 in lymphocytes, and hemoglobin (Hb) in approximately 25 minutes. CD4 cell count is used with portable CD4 counters in resource-limited settings to manage HIV/AIDS patients. A method comparison was performed using capillary and venous samples from seven clinical laboratories in five countries.

View Article and Find Full Text PDF

Background: The BD FACSPresto™ Near-Patient CD4 Counter was developed to expand HIV/AIDS management in resource-limited settings. It measures absolute CD4 counts (AbsCD4), percent CD4 (%CD4), and hemoglobin (Hb) from a single drop of capillary or venous blood in approximately 23 minutes, with throughput of 10 samples per hour. We assessed the performance of the BD FACSPresto system, evaluating accuracy, stability, linearity, precision, and reference intervals using capillary and venous blood at KEMRI/CDC HIV-research laboratory, Kisumu, Kenya, and precision and linearity at BD Biosciences, California, USA.

View Article and Find Full Text PDF

Background Aims: Evaluation of the BD Stem Cell Enumeration Kit was conducted at four clinical sites with flow cytometry CD34(+) enumeration to assess agreement between two investigational methods: (i) the BD FACSCanto II and BD FACSCalibur systems and (ii) the predicate method (Beckman Coulter StemKit and StemTrol, Immunotech SAS, Beckman Coulter, Marseille Cedex 9, France).

Methods: Leftover and delinked specimens (n = 1032) from clinical flow cytometry testing were analyzed on the BD FACSCanto II (n = 918) and BD FACSCalibur (n = 905) in normal and mobilized blood, frozen and thawed bone marrow and leucopheresis and cord blood anticoagulated with citrate phosphate dextrose, anticoagulant citrate dextrose-solution A, heparin and ethylenediaminetetraacetate, alone or in combination. Fresh leucopheresis analysis addressed site equivalency for sample preparation, testing and analysis.

View Article and Find Full Text PDF