Purpose: To evaluate the accuracy of cone-beam computed tomography (CT)-based augmented fluoroscopy (AF) image guidance for endobronchial navigation to peripheral lung targets.

Methods: Prototypic endobronchial navigation AF software that superimposed segmented airways, targets, and pathways based on cone-beam CT onto fluoroscopy images was evaluated ex vivo in fixed swine lungs and in vivo in healthy swine (n = 4) without a bronchoscope. Ex vivo and in vivo (n = 3) phase 1 experiments used guide catheters and AF software version 1, whereas in vivo phase 2 (n = 1) experiments also used an endovascular steerable guiding sheath, upgraded AF software version 2, and lung-specific low-radiation-dose protocols.

View Article and Find Full Text PDF

Background: Bypassing the emergency department and the computed tomography suite by directly transporting to the neuroangiography suite for imaging assessment and treatment may shorten reperfusion times while maintaining proper patient selection.

Objective: To determine whether flat-panel detector multiphase computed tomography angiography protocol is associated with reduced treatment times and a similar safety profile as the standard imaging protocol.

Methods: Single-center prospective study of consecutive patients with anterior circulation large vessel occlusion strokes transferred to our facility for consideration of endovascular therapy from May 2016 to December 2017.

View Article and Find Full Text PDF

Purpose: Dose calculation for transarterial radioembolization (TARE) with glass yttrium-90 (Y) labeled microspheres is based on liver lobe and tumor volumes, currently measured from preprocedural MRI or CT. The variable time between MRI and radioembolization may not account for relevant tumor progression. Advances in cone beam computed tomography (CBCT) allow for intra-procedural assessment of these volumes that avoids this factor.

View Article and Find Full Text PDF

Background: Electromagnetic navigation bronchoscopy (ENB) has been widely adopted as a guidance technique for biopsy of peripheral lung nodules. However, ENB is limited by the lack of real-time confirmation of the biopsy devices. Intraprocedural cone-beam computed tomography (CBCT) imaging can be utilized to assess or confirm the location of biopsy devices.

View Article and Find Full Text PDF

Purpose: To determine the true distribution of radiopaque beads (ROBs) after hepatic embolization in swine as imaged by micro-computed tomography (microCT) compared with in vivo cone-beam computerized tomography (CT) imaged at different kVp settings.

Materials And Methods: Swine (n = 3) underwent hepatic transarterial embolization (n = 6) with the use of 70-150-μm ROBs under fluoroscopic guidance. After stasis, in vivo cone-beam CT was performed at 120, 100, and 80 kVp.

View Article and Find Full Text PDF