Publications by authors named "I Gamboa-Debuen"

To estimate the mean effective dose per procedure with multiple dosimetry, to calculate the annual effective dose to personnel working in neuroendovascular procedures and compared with methods reported in the literature and with national and international limits. The radiation dose to personnel was monitored in 20 procedures classified as diagnostic or therapeutic. During each procedure, the equivalent dose to eyes, thyroid, under and over the lead apron at chest level, hands, gonads and knees was measured with lithium fluoride thermoluminescent dosimeter chips (TLD-100).

View Article and Find Full Text PDF

Purpose: The purpose of this study was to evaluate the photon field effective energy (E ) distribution and percentage depth-dose (PDD) within a mammography phantom by the analysis of the CaF :Tm (TLD-300) thermoluminescent (TL) glow curve. The experimental procedure involves the use of TLD-300 to determine with single dosimeter exposures both the relative dose and the beam quality.

Methods: TLD-300 chips were exposed to x rays from a GE Senographe 2000D mammography unit at the surface and different depths within a BR12 phantom.

View Article and Find Full Text PDF

We study the high- to low- temperature signal ratio (HLTR) of the CaF2:Tm glow curve as a function of beam quality for low-energy photon beams with effective energy between 15.2 and 33.6 keV, generated with W, Mo and Rh anodes.

View Article and Find Full Text PDF

This work evaluates the radiological risk that patients treated with I for differentiated thyroid cancer could present to relatives and occupationally exposed workers. Recently, the International Atomic Energy Agency issued document K9010241, which recommends that patient discharge from the hospital must be based on the particular status of each patient. This work measures effective dose received by caregivers of patients treated with I at the Instituto Nacional de Cancerología, Mexico City.

View Article and Find Full Text PDF

Purpose: To assess the impact of the detector used to commission small photon beams on the calculated dose distribution in stereotactic radiosurgery (SRS).

Methods: In this study, six types of detectors were used to characterize small photon beams: three diodes [a silicon stereotactic field diode SFD, a silicon diode SRS, and a silicon diode E], an ionization chamber CC01, and two types of radiochromic film models EBT and EBT2. These detectors were used to characterize circular collimated beams that were generated by a Novalis linear accelerator.

View Article and Find Full Text PDF