Interference removal in inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) is strongly dependent on the gas selected for use within the collision/reaction cell. There has been little investigation on the effects that reaction gas impurities may have on the resulting spectra. The reactivity of 60 elements was evaluated using nitric oxide (NO 99.
View Article and Find Full Text PDFEur Phys J C Part Fields
May 2024
Noble element time projection chambers are a leading technology for rare event detection in physics, such as for dark matter and neutrinoless double beta decay searches. Time projection chambers typically assign event position in the drift direction using the relative timing of prompt scintillation and delayed charge collection signals, allowing for reconstruction of an absolute position in the drift direction. In this paper, alternate methods for assigning event drift distance via quantification of electron diffusion in a pure high pressure xenon gas time projection chamber are explored.
View Article and Find Full Text PDFUnderstanding the reactivity of metal cations with various reaction gases in inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) is important to determine the best gas to use for a given analyte/interference pair. In this study, nitric oxide (NO) was investigated as the reaction gas following previous experimental designs. The reactions with 50 elements were investigated to examine periodic trends in reactivity, validate theoretical modeling of reaction enthalpies as a method to screen reactant gases, and provide a baseline data set for potential in-line gas separation methods.
View Article and Find Full Text PDFDark matter (DM) particles with sufficiently large cross sections may scatter as they travel through Earth's bulk. The corresponding changes in the DM flux give rise to a characteristic daily modulation signal in detectors sensitive to DM-electron interactions. Here, we report results obtained from the first underground operation of the DAMIC-M prototype detector searching for such a signal from DM with MeV-scale mass.
View Article and Find Full Text PDFThe effect of ion kinetic energy on gas phase ion reactivity with ICP-MS/MS was investigated in order to explore tuning strategies for interference removal. The collision/reaction gases CO, NO and O were used to observe the ion product distribution for 48 elements using an Agilent tandem ICP-MS (ICP-MS/MS) as a function of reaction gas flow rate (pressure) and ion kinetic energy. The kinetic energy of the incident ion was varied by adjusting the octopole bias (V).
View Article and Find Full Text PDF