J Korean Soc Radiol
March 2024
Superficial radial neuropathy is a purely sensory neuropathy, usually caused by nerve entrapment in the distal forearm. We report a case of superficial radial neuropathy caused by the anomalous course of the superficial radial nerve, which was found to be spirally encircling the brachioradialis tendon in the distal forearm. To the best of our knowledge, this is the first report of an anatomical variant of the superficial radial nerve that causes neuropathy.
View Article and Find Full Text PDFImmunoglobulin G4 (IgG4)-related disease is a rare systemic fibroinflammatory condition characterized by organomegaly or tumefactive lesions associated with lymphoplasmacytic infiltration rich in IgG4 plasma cells. We report a case of IgG4-related disease involving the subcutaneous layer of the left upper arm in a 48-year-old female presenting with an unusual soft tissue mass. US and MRI showed an irregular infiltrative soft tissue mass, indicating possible malignancy or inflammation.
View Article and Find Full Text PDFPurpose: To compare the MR findings of septic and acute gouty arthritis of the knee joint.
Materials And Methods: This retrospective study included patients who underwent knee MRI for septic or gouty arthritis at our hospital between October 2012 and October 2018. The MR findings were analyzed for the presence of bone marrow edema, soft tissue edema, abscess, pattern of synovial thickening (frondlike, lamellated, diffuse linear), maximum thickness of the synovium, and joint effusion volume.
Chronic inflammatory condition associated with metallic implant insertion is a risk factor for diffuse large B-cell lymphoma (DLBCL). Metal ions play a role in the pathogenesis of lymphoma. We report a rare case of DLBCL in a patient who had a metallic implant in the proximal tibia for 15 months.
View Article and Find Full Text PDFObjective: The aim of the study was to retrospectively evaluate the safety and accuracy of computed tomography (CT)-guided percutaneous transthoracic needle biopsy (PTNB) of lung lesions during quiet breathing.
Methods: We investigated the diagnostic performance and complication rate of 585 procedures in 563 patients (357 men; mean age, 67.7 years), who underwent CT-guided PTNBs during quiet breathing, aided by a respiratory targeting technique from May 2017 to July 2019.
Background: The delayed diagnosis of developmental dysplasia of the hip (DDH) requires complex treatment and sometimes progresses to hip osteoarthritis.
Purpose: This study aimed to evaluate the risk factors and screening time for DDH in preterm infants.
Methods: A total of 155 preterm infants with a gestational age <32 weeks screened for DDH with ultrasonography were enrolled in this retrospective chart review.
Avulsion injuries result from the application of a tensile force to a musculoskeletal unit or ligament. Although injuries tend to occur more commonly in skeletally immature populations due to the weakness of their apophysis, adults may also be subject to avulsion fractures, particularly those with osteoporotic bones. The most common sites of avulsion injuries in adolescents and children are apophyses of the pelvis and knee.
View Article and Find Full Text PDFObjective: To compare the quality of various polychromatic and monochromatic images with or without using an iterative metal artifact reduction algorithm (iMAR) obtained from a dual-energy computed tomography (CT) to evaluate total knee arthroplasty.
Materials And Methods: We included 58 patients (28 male and 30 female; mean age [range], 71.4 [61-83] years) who underwent 74 knee examinations after total knee arthroplasty using dual-energy CT.
Taehan Yongsang Uihakhoe Chi
January 2021
Purpose: We evaluated the risk factors for progression to chronic complicated bronchopleural fistula (BPF) after pulmonary resection using follow-up CT.
Materials And Methods: We retrospectively reviewed 45 cases with BPF that had undergone pulmonary resection during 2010-2018. We compared the clinical and radiological characteristics of those with complicated BPF ( = 24) and those without complicated (sterilized) BPF ( = 21).
Background: Tin filter-based spectral shaping has been used for low-dose and ultra-low-dose computed tomography (CT) in several body parts. However, studies of shoulder CT arthrography with spectral shaping are limited.
Purpose: To investigate image quality and radiation dose of shoulder CT arthrography with tin filter-based spectral shaping at 100 kV (Sn 100 kV) and 140 kV (Sn 140 kV) in comparison with the conventional protocol.
Background: Although time-of-flight magnetic resonance angiography (TOF-MRA) is widely used, it has limited usefulness for follow-up after stent-assisted coil embolization. Contrast-enhanced MRA (CE-MRA) and ultrashort echo time MRA have been suggested as alternative methods for visualization after this procedure.
Purpose: To compare efficacy and usefulness of pointwise encoding time reduction with radial acquisition (PETRA) sequence in subtraction-based MRA (qMRA), TOF-MRA, and CE-MRA during the follow-up after Neuroform Atlas stent-assisted coil embolization for intracranial aneurysms.
This study aimed to compare ultrasonography (US) features and the Korean-Thyroid Imaging Reporting and Data System (K-TIRADS) categories for diagnosing isthmic and lobar papillary thyroid carcinomas (PTC). From January 2009 to December 2012, 163 patients who underwent thyroid surgery and were confirmed with a post-operative histopathological diagnosis of isthmic PTC were retrospectively included. Fifty-nine patients were excluded because their tumor size was <0.
View Article and Find Full Text PDFThe relationship between radioactive iodine therapy (RIT) and prevalence of thyroglossal duct cysts (TGDC) on ultrasonography (US) has not been reported. We assessed the prevalence and US features of TGDC according to RIT. From July 2017 to June 2018, 3,146 subjects underwent thyroid or neck US at our center.
View Article and Find Full Text PDFAccording to the reports presented at the Fourth Asian Oceanian Radiology Forum (AORF) 2018, organized by the Korean Society of Radiology during the Korean Congress of Radiology in September 2018 in Seoul, there is an increasing demand for the Asian Oceanian Society of Radiology and its member societies for international education in radiology in the Asian Oceanian region. In AORF 2018, the national delegates of the Asian Oceanian radiological partner societies primarily discussed their societies' activities and current status of international education in radiology.
View Article and Find Full Text PDFTaehan Yongsang Uihakhoe Chi
January 2020
Metallic artifacts on MR imaging are typically induced by differences in magnetic susceptibility between the metallic implant and surrounding tissue. Conventional techniques for metal artifact reduction require MR machines with low field strength, shift in the frequency-encoding and phase-encoding directions according to the axis of metallic implant, increased receiver bandwidth and matrix, decreased slice thickness, and utilization of the short tau inversion recovery or Dixon method for fat-suppression. Slice-encoding for metal artifact correction and multi-acquisition variable-resonance image combination can dramatically reduce the number of metallic artifacts.
View Article and Find Full Text PDFBACKGROUND This study aimed to evaluate the prevalence of thyroglossal duct cysts (TGDCs) on ultrasonography (US) and US features of TGDCs in adults, and to assess whether the prevalence or size of TGDCs increases after radioactive iodine ablation (RIA). MATERIAL AND METHODS Between July and December 2018, 2820 patients underwent thyroid or neck US examination, performed by 2 radiologists, at our center. On the basis of real-time US, the presence or absence of TGDCs was prospectively investigated by 2 radiologists.
View Article and Find Full Text PDFFront Endocrinol (Lausanne)
November 2019
Benign thyroid follicular tumors without histological evidence of carcinoma can metastasize. However, the pathogenesis of metastasis remains unclear. Here, the new proposed terminology, "non-invasive follicular thyroid neoplasm with papillary-like nuclear features" should be considered.
View Article and Find Full Text PDFThis study aimed to compare the ultrasonography (US) features of diffuse thyroid disease (DTD) and normal thyroid parenchyma (NTP), and to propose a structured imaging reporting system for detecting DTD. This retrospective study assessed the findings for 270 consecutive patients who underwent thyroid US before thyroid surgery. The following US data were analyzed: DTD-specific features, parenchymal echotexture and echogenicity, anteroposterior diameter, glandular margin, and parenchymal vascularity.
View Article and Find Full Text PDFBACKGROUND This study aimed to assess the utility and characteristics of preoperative ultrasonography (US) in patients transferred to referral hospitals from local clinics with a diagnosis of malignancy on US-guided fine-needle aspiration cytology of thyroid nodules. MATERIAL AND METHODS From January 2018 to June 2018, 109 transferred patients underwent preoperative US in our hospital for suspected thyroid malignancy on cytological analysis after US-guided fine-needle aspiration of thyroid nodules in local clinics. Preoperative US was performed by a single radiologist in all patients.
View Article and Find Full Text PDFIn this study, we compared ultrasound (US) features between normal parotid parenchyma (NPP) and incidental diffuse parotid disease (DPD). From January 2008 to December 2017, 180 patients underwent neck US before parotid surgery at our hospital. From these, 82 were excluded because of the lack of histopathological data concerning the parotid parenchyma or inadequate US images.
View Article and Find Full Text PDFObjective: To investigate the relationships of T₂-corrected 6-echo Dixon volumetric interpolated breath-hold examination (VIBE) imaging-based fat fraction (FF) and R₂ values with bone mineral density (BMD); determine their associations with sex, age, and menopause; and evaluate the diagnostic performance of the FF and R₂ for predicting osteopenia and osteoporosis.
Materials And Methods: This study included 153 subjects who had undergone magnetic resonance (MR) imaging, including MR spectroscopy (MRS) and T₂-corrected 6-echo Dixon VIBE imaging. The FF and R₂ were measured at the L4 vertebra.
In ultrasound (US)-guided fine-needle aspiration (FNA) of solid thyroid nodules (STN) using liquid-based cytology (LBC), the most appropriate needle size for LBC remains unclear. This study compared the cytological adequacy and complications associated with using 23- and 25-gauge needles in US-guided FNA of STNs using LBC. US-guided FNA was performed in consecutive patients by one radiologist to diagnose STNs ≥ 5 mm in the largest diameter.
View Article and Find Full Text PDFObjective: To investigate the image quality, radiation dose, and intermodality agreement of cervical spine CT using spectral shaping at 140 kVp by a tin filter (Sn140-kVp) in comparison with those of conventional CT at 120 kVp.
Materials And Methods: Patients who had undergone cervical spine CT with Sn140-kVp (n = 58) and conventional 120 kVp (n = 49) were included. Qualitative image quality was analyzed using a 5-point Likert scale.
Purpose: To evaluate the diagnostic performance, image quality, artifacts, and radiation doses of virtual non-contrast (VNC) images, relative to true non-contrast (TNC) images, in patients with surgically clipped aneurysms.
Methods: Seventy-six patients who underwent unenhanced computed tomography (CT) and dual-energy (DE)-CT angiography after surgical clipping of 85 intracranial aneurysms were included in the study. Diagnostic performances of VNC and TNC images were compared with respect to sensitivity, specificity, and positive and negative predictive values.
This study aimed to assess the diagnostic performance of computed tomography (CT) for differentiating diffuse thyroid disease (DTD) from normal thyroid parenchyma (NTP) using multicenter data. Between January 2016 and June 2016, 229 patients underwent preoperative neck CT and subsequent thyroid surgery at five participating institutions. The neck CT images of each patient were retrospectively reviewed and classified into the following four categories: no DTD, indeterminate, suspicious for DTD, and DTD.
View Article and Find Full Text PDF