Publications by authors named "Hwan Hur"

Spiral-phase-contrast imaging, which utilizes a spiral phase optical element, has proven to be effective in enhancing various aspects of imaging, such as edge contrast and shadow imaging. Typically, the implementation of spiral-phase-contrast imaging requires the formation of a Fourier plane through a 4f optical configuration in addition to an existing optical microscope. In this study, we present what we believe to be a novel single spiral-phase-objective, integrating a spiral phase plate, which can be easily and simply applied to a standard microscope, such as a conventional objective.

View Article and Find Full Text PDF

Spectrally encoded confocal microscopy (SECM) is a high-speed reflectance confocal microscopy technique. Here, we present a method to integrate optical coherence tomography (OCT) and SECM for complementary imaging by adding orthogonal scanning to the SECM configuration. The co-registration of SECM and OCT is automatic, as all system components are shared in the same order, eliminating the need for additional optical alignment.

View Article and Find Full Text PDF

Biochip-based research is currently evolving into a three-dimensional and large-scale basis similar to the in vivo microenvironment. For the long-term live and high-resolution imaging in these specimens, nonlinear microscopy capable of label-free and multiscale imaging is becoming increasingly important. Combination with non-destructive contrast imaging will be useful for effectively locating regions of interest (ROI) in large specimens and consequently minimizing photodamage.

View Article and Find Full Text PDF

Wavelength-tunable spiral-phase-contrast (SPC) imaging was experimentally accomplished in the visible wavelengths spanning a broad bandwidth of ∼200 nm based on a single off-axis spiral phase mirror (OSPM). By the rotation of an OSPM, which was designed with an integer orbital angular momentum (OAM) of l = 1 at a wavelength of 561 nm and incidence angle of 45°, high-quality SPC imaging was obtained at different wavelengths. For the comparison with wavelength-tunable SPC imaging using an OSPM, SPC imaging using a spiral phase plate (manufactured to generate an OAM of l = 1 at 561 nm) was performed at three wavelengths (473, 561, and 660 nm), resulting in clear differences.

View Article and Find Full Text PDF

Plasmonic photothermal therapy (PPTT) using gold nanoparticles (AuNPs) has shown great potential for use in selective tumor treatment, because the AuNPs can generate destructive heat preferentially upon irradiation. However, PPTT using AuNPs has not been added to practice, owing to insufficient heating methods and tissue temperature measurement techniques, leading to unreliable and inaccurate treatments. Because the photothermal properties of AuNPs vary with laser power, particle optical density, and tissue depth, the accurate prediction of heat generation is indispensable for clinical treatment.

View Article and Find Full Text PDF

In this study, a portable and large-area blackbody system was developed following a series of processes including design, computational analysis, fabrication, and experimental analysis and evaluation. The blackbody system was designed to be lightweight (5 kg), and its temperature could exceed the ambient temperature by up to 15 °C under operation. A carbon-fiber-based heat source was used to achieve a uniform temperature distribution.

View Article and Find Full Text PDF

We report a new, to the best of our knowledge, approach to correct image blurring due to the axial bulk motion of a sample in wavelength-sweeping Fourier domain parallel optical coherence tomography (OCT). This approach can estimate phase errors changing rapidly in time through direct measurements of the apparent axial shift during the sampling interval using common phase changes in parallel detection without additional hardware. To demonstrate the performance of the proposed algorithm, a single reflection and scattering sample were imaged with wavelength-sweeping parallel OCT implemented by scanning a spectrally dispersed line-field along the line direction.

View Article and Find Full Text PDF

In this paper, we report on a confocal thermoreflectance imaging system that can examine the thermal characteristics of microelectronic devices by penetrating the backside of a device through the substrate. In this system, the local reflectivity variations due to heat generation in the device are measured point by point by a laser scanning confocal microscope capable of eliminating out-of-focus reflections and the thermoreflectance is extracted via Fourier-domain signal processing. In comparison to the conventional widefield thermoreflectance microscope, the proposed laser scanning confocal thermoreflectance microscope improves the thermoreflectance sensitivity by ~23 times and the spatial resolution by ~25% in backside thermoreflectance measurements.

View Article and Find Full Text PDF

Micro-electronic devices are increasingly incorporating miniature multi-layered integrated architectures. However, the localization of faults in three-dimensional structure remains challenging. This study involved the experimental and numerical estimation of the depth of a thermally active heating source buried in multi-layered silicon wafer architecture by using both phase information from an infrared microscopy and finite element simulation.

View Article and Find Full Text PDF

We demonstrate a fiber-optic-based parallel optical coherence tomography (OCT) using spectrally encoded extended illumination with a common-path handheld probe, where the flexibility and robustness of the system are significantly improved, which is critical in the clinical environment. To the best of our knowledge, we present the first parallel OCT based on fiber optics including a fiber coupler with a sensitivity of 94 dB, which is comparable to that of point-scanning OCT. We also investigated the effect of the phase stability of the fiber-based interferometry on the parallel OCT system by comparing the common-path OCT with two-arm OCT.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionodmu9klsubo783ub56qjl7foavbhsfka): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once