Publications by authors named "Hutten G"

Background: Physiological-based cord clamping (PBCC) in preterm infants is beneficial for cardiovascular transition at birth and may optimize placental transfusion. Whether PBCC can improve clinical outcomes is unknown. The aim of the Aeration, Breathing, Clamping (ABC3) trial was to test whether PBCC results in improved intact survival in very preterm infants.

View Article and Find Full Text PDF

Introduction: Caffeine is the registered pharmacologic treatment for apnea of prematurity and is extensively used in the neonatal intensive care units (NICUs) based on evidence from randomized controlled trials. This study aimed to describe the clinical use of caffeine based on real-world data, hypothesizing a divergence from the registered dosing regimen.

Methods: A retrospective analysis included infants born before 30 weeks of gestation, admitted to the NICU of the Erasmus MC Rotterdam from 2018 to 2021.

View Article and Find Full Text PDF
Article Synopsis
  • The systematic review analyzes lung function in preterm-born children, who face increased risks of respiratory issues due to immature lung development.
  • It includes data from 42 studies with over 4,700 preterm children, revealing they have significantly lower forced expiratory volume (FEV) compared to term-born peers.
  • Key risk factors affecting FEV include gestational age, birthweight, bronchopulmonary dysplasia, and the use of mechanical ventilation, indicating that early developmental issues heavily influence long-term pulmonary health.
View Article and Find Full Text PDF

Objective: This study aims to evaluate the performance of the fabian-Predictive-Intelligent-Control-of-Oxygenation (PRICO) system for automated control of the fraction of inspired oxygen (FiO).

Design: Multicentre randomised cross-over study.

Setting: Five neonatal intensive care units experienced with automated control of FiO and the fabian ventilator.

View Article and Find Full Text PDF
Article Synopsis
  • The ABC3 trial investigates the potential benefits of physiological-based cord clamping (PBCC) compared to standard time-based cord clamping (TBCC) for very preterm infants, aiming to reduce complications like cerebral injury and necrotizing enterocolitis (NEC).
  • It is a multicenter, randomized clinical trial involving infants born before 30 weeks of gestation, assessing outcomes such as intact survival and short-term co-morbidities during NICU admission.
  • The results of this study will inform future clinical guidelines regarding optimal cord clamping practices at birth to enhance infant health outcomes.
View Article and Find Full Text PDF

Aim: The aim of our study was to investigate skin conditions when wearing and removing a novel wireless non-adhesive cardiorespiratory monitoring device for neonates (Bambi-Belt) compared to standard adhesive electrodes.

Study Design: This was a prospective study including preterm neonates requiring cardiorespiratory monitoring. Besides standard electrodes, the infants wore a Bambi Belt for 10 consecutive days.

View Article and Find Full Text PDF

Objective: This randomised study in preterm infants on non-invasive respiratory support investigated the effectiveness of automated oxygen control (A-FiO) in keeping the oxygen saturation (SpO) within a target range (TR) during a 28-day period compared with manual titration (M-FiO).

Design: A single-centre randomised control trial.

Setting: A level III neonatal intensive care unit.

View Article and Find Full Text PDF

Background: Apnoea of prematurity (AOP) is one of the most common diagnoses among preterm infants. AOP often leads to hypoxemia and bradycardia which are associated with an increased risk of death or disability. In addition to caffeine therapy and non-invasive respiratory support, doxapram might be used to reduce hypoxemic episodes and the need for invasive mechanical ventilation in preterm infants, thereby possibly improving their long-term outcome.

View Article and Find Full Text PDF

Introduction: We determined if the heart rate (HR) monitoring performance of a wireless and nonadhesive belt is non-inferior compared to standard electrocardiography (ECG). Secondary objective was to explore the belt's respiratory rate (RR) monitoring performance compared to chest impedance (CI).

Method: In this multicenter non-inferiority trial, preterm and term infants were simultaneously monitored with the belt and conventional ECG/CI for 24 h.

View Article and Find Full Text PDF

Preterm infants often experience breathing instability and a hampered lung function. Therefore, these infants receive cardiorespiratory monitoring and respiratory support. However, the current respiratory monitoring technique may be unreliable for especially obstructive apnea detection and classification and it does not provide insight in breathing effort.

View Article and Find Full Text PDF

Background: International guidelines recommend delayed umbilical cord clamping (DCC) up to 1 min in preterm infants, unless the condition of the infant requires immediate resuscitation. However, clamping the cord prior to lung aeration may severely limit circulatory adaptation resulting in a reduction in cardiac output and hypoxia. Delaying cord clamping until lung aeration and ventilation have been established (physiological-based cord clamping, PBCC) allows for an adequately established pulmonary circulation and results in a more stable circulatory transition.

View Article and Find Full Text PDF

Introduction: Cardiorespiratory monitoring is used in the neonatal intensive care unit (NICU) to assess the clinical status of newborn infants and detect critical deteriorations in cardiorespiratory function. Currently, heart rate (HR) is monitored by electrocardiography (ECG) and respiration by chest impedance (CI). Disadvantages of current monitoring techniques are usage of wired adhesive electrodes which may damage the skin and hinder care.

View Article and Find Full Text PDF

Introduction: Current cardiorespiratory monitoring in neonates with electrocardiogram (ECG) and chest impedance (CI) has limitations. Adding transcutaneous electromyography of the diaphragm (dEMG) may improve respiratory monitoring, but requires additional hardware. We aimed to determine the feasibility of measuring dEMG and ECG/CI simultaneously using the standard ECG/CI hardware, with its three electrodes repositioned to dEMG electrode locations.

View Article and Find Full Text PDF

Monitoring heart rate (HR) and respiratory rate (RR) is essential in preterm infants and is currently measured with ECG and chest impedance (CI), respectively. However, in current clinical practice these techniques use wired adhesive electrodes which can cause skin damage and hinder parent-infant interaction. Moreover, CI is not always reliable.

View Article and Find Full Text PDF

Objectives: Swift extubation is important to prevent detrimental effects of invasive mechanical ventilation but carries the risk of extubation failure. Accurate tools to assess extubation readiness are lacking. This study aimed to describe the effect of extubation on diaphragm activity in ventilated infants and children.

View Article and Find Full Text PDF

Objective: Monitoring work of breathing (WOB) is important to assess the pulmonary condition and adjust respiratory support in preterm infants. Conventional WOB measurement (esophageal pressure, tidal volume) is invasive and we hypothesized that monitoring diaphragm activity could be a noninvasive alternative to estimate WOB. The objective was to determine the correlation between conventional WOB measures and diaphragm activity, in preterm infants.

View Article and Find Full Text PDF

Objective: To assess feasibility of transcutaneous electromyography of the diaphragm (dEMG) as a monitoring tool for vital signs and diaphragm activity in the delivery room (DR).

Design: Prospective observational study.

Setting: Delivery room.

View Article and Find Full Text PDF

Objective: To determine the effect of changing electrode positions on vital signs and respiratory effort parameters measured with transcutaneous electromyography of the diaphragm (dEMG) in preterm infants.

Methods: In this observational study, simultaneous dEMG measurements were performed at the standard position and at one alternative electrode position (randomly assigned to lateral, superior, medial, inferior to the standard placement, or dorsal). The activity of the diaphragm was measured for 1 hour at both positions.

View Article and Find Full Text PDF

Transcutaneous electromyography (tc-EMG) has been used to measure the electrical activity of respiratory muscles during inspiration in various studies. Processing the raw tc-EMG signal of these inspiratory muscles has shown to be difficult as baseline noise, cardiac interference, cross-talk and motion artefacts can influence the signal quality. In this review we will discuss the most important sources of signal noise in tc-EMG of respiratory muscles and the various techniques described to suppress or reduce this signal noise.

View Article and Find Full Text PDF

Although most preterm infants breathe at birth, their respiratory drive is weak and supplemental oxygen is often needed to overcome hypoxia. This could in turn lead to hyperoxia. To reduce the risk of hyperoxia, currently an initial low oxygen concentration (21-30%) is recommended during stabilization at birth, accepting the risk of a hypoxic period.

View Article and Find Full Text PDF

Most preterm infants fail to aerate their immature lungs at birth and need respiratory support for cardiopulmonary stabilization. Cord clamping before lung aeration compromises cardiovascular function. Delaying cord clamping until the lung has aerated may be beneficial for preterm infants by optimizing hemodynamic transition and placental transfusion.

View Article and Find Full Text PDF

Background: Doxapram is a treatment option for severe apnea of prematurity (AOP). However, the effect of doxapram on the diaphragm, the main respiratory muscle, is not known.

Objectives: To investigate the effect of doxapram on diaphragmatic activity measured with transcutaneous electromyography of the diaphragm (dEMG).

View Article and Find Full Text PDF

Objective: To describe the incidence of patient-ventilator asynchrony and different types of asynchrony in preterm infants treated with non-synchronised nasal intermittent positive pressure ventilation (nIPPV).

Design: An observational study was conducted including preterm infants born with a gestational age (GA) less than 32 weeks treated with non-synchronised nIPPV. During 1 hour, spontaneous breathing was measured with transcutaneous electromyography of the diaphragm simultaneous with ventilator inflations.

View Article and Find Full Text PDF