Publications by authors named "Hussin Azlan"

Background: Advances in leadless pacemaker technology have enabled accelerometer-based atrioventricular (AV) synchronous pacing by sensing atrial mechanical contraction.

Objective: The purpose of this study was to report the performance of the Micra AV leadless pacemaker from the worldwide Micra AV post-approval registry (PAR) through 12 months.

Methods: The Micra AV PAR is a prospective, single-arm, observational registry designed to assess the safety and effectiveness of Micra AV in a real-world setting.

View Article and Find Full Text PDF

Background: Comprehensive data on patients at high risk of sudden cardiac death (SCD) in emerging countries are lacking. The aim was to deepen our understanding of the SCD phenotype and identify risk factors for death among patients at high risk of SCD in emerging countries.

Methods: Patients who met the class I indication for implantable cardioverter-defibrillator (ICD) implantation according to guideline recommendations in 17 countries and regions underrepresented in previous trials were enrolled.

View Article and Find Full Text PDF

Aims: The HINODE study aimed to analyse rates of mortality, appropriately treated ventricular arrhythmias (VA), and heart failure in Japanese patients and compared with those in Western patients.

Methods And Results: After treatment decisions following contemporary practice in Japan, patients were prospectively enrolled into four cohorts: (i) internal cardioverter-defibrillator (ICD), (ii) cardiac resynchronization therapy (CRT) defibrillator (CRT-D), (iii) standard medical therapy ('non-device': ND), or (iv) pacing (indicated for CRT; received pacemaker or CRT pacing). Cohorts 1-3 required a left ventricular ejection fraction ≤35%, a history of heart failure, and a need for primary prevention of sudden cardiac death based on two to five previously identified risk factors.

View Article and Find Full Text PDF

Background: In primary prevention (PP) patients the utilization of implantable cardioverter-defibrillators (ICD) and cardiac resynchronization therapy-defibrillators (CRT-D) remains low in many geographies, despite the proven mortality benefit.

Purpose: The objective of this analysis was to examine the mortality benefit in PP patients by guideline-indicated device type: ICD and CRT-D.

Methods: Improve sudden cardiac arrest was a prospective, nonrandomized, nonblinded multicenter trial that enrolled patients from regions where ICD utilization is low.

View Article and Find Full Text PDF

Background: Implantable cardioverter-defibrillators (ICDs) are underutilized in Asia, Latin America, Eastern Europe, the Middle East, and Africa. The Improve SCA Study is the largest prospective study to evaluate the benefit of ICD therapy in underrepresented geographies. This analysis reports the primary objective of the study.

View Article and Find Full Text PDF

Background: Despite available evidence that implantable cardioverter defibrillators (ICDs) reduce all-cause mortality among patients at risk for sudden cardiac death, utilization of ICDs is low especially in developing countries.

Objective: To summarize reasons for ICD or cardiac resynchronization therapy defibrillator implant refusal by patients at risk for sudden cardiac arrest (Improve SCA) in developing countries.

Methods: Primary prevention (PP) and secondary prevention (SP) patients from countries where ICD use is low were enrolled.

View Article and Find Full Text PDF

Background: Steroid-eluting (SE) electrodes suppress local inflammation and lower pacing capture thresholds (PCT); however, their effectiveness on quadripolar left ventricular (LV) leads in the cardiac vein is not fully studied. We evaluated the effectiveness of SE on all four LV pacing electrodes in human subjects enrolled in the Medtronic Attain® Performa™ quadripolar LV lead study.

Methods: A total of 1,097 subjects were included in this evaluation.

View Article and Find Full Text PDF

Aims: Biventricular (BiV) pacing was superior to right ventricular apical (RVA) pacing at extended follow-up in the Pacing to Avoid Cardiac Enlargement (PACE) trial. Early pacing-induced systolic dyssynchrony (DYS) might be related to mid-term result. However, it remains unknown whether early pacing-induced DYS can predict long-term reduction of left ventricular (LV) systolic function.

View Article and Find Full Text PDF

Aims: This study aims to demonstrate that primary prevention (PP) patients with one or more additional risk factors are at a similar risk of life-threatening ventricular arrhythmias when compared with secondary prevention (SP) patients, and would receive similar benefit from an implantable cardioverter defibrillator (ICD), or cardiac resynchronization therapy-defibrillator (CRT-D) implant. The study evaluates the benefits of therapy for high-risk patients in countries where defibrillation therapy for PP of SCA is underutilized.

Methods: Enrolment will consist of 4800 ICD-eligible patients from Asia, Latin America, Eastern Europe, the Middle East, and Africa.

View Article and Find Full Text PDF

Background: The Asian population with atrial fibrillation (AF) have a higher risk of stroke than the caucasian population and a higher risk of intracranial bleeding when anticoagulated with warfarin. There are few real-world studies comparing the efficacy of non-vitamin K antagonist oral anticoagulants (NOACs) and warfarin among Asian patients to assess its outcomes of ischemic stroke and hemorrhagic stroke.

Methods: A retrospective cohort study of 1000 patients on dabigatran and warfarin from 2009 to 2013.

View Article and Find Full Text PDF

Background: The Medtronic Attain Performa quadripolar leads provide 16 pacing vectors with steroid on every electrode. This includes a short bipolar configuration between the middle 2 electrodes.

Objective: A prospective clinical study was conducted to investigate the safety and effectiveness of these new leads in 27 countries.

View Article and Find Full Text PDF

Aims: We report the results of long-term follow-up of the Pacing to Avoid Cardiac Enlargement (PACE) trial, a prospective, double-blinded, randomized, multicentre study that confirmed the superiority of biventricular (BiV) pacing compared with right ventricular apical (RVA) pacing in prevention of LV adverse remodelling and deterioration of systolic function at 1 and 2 years.

Methods And Results: Patients with bradycardia and preserved LVEF were randomized to receive RVA (n = 88) or BiV pacing (n = 89). Co-primary endpoints were LV end-systolic volume (LVESV) and LVEF measured by echocardiography.

View Article and Find Full Text PDF

Background: Left ventricular (LV) lead implantation for cardiac resynchronization therapy (CRT) is associated with lead dislodgement rates ranging from 3% to 10%, and some implant approaches to prevent dislodgement may contribute to suboptimal CRT response. We report our early human experience with an LV lead with a side helix for active fixation to the coronary vein wall.

Objectives: To assess the feasibility and safety of the Model 20066 LV lead and to evaluate the implant procedure.

View Article and Find Full Text PDF

The use of novel anticoagulants such as dabigatran are increasing. Despite increased risks of intracerebral haemorrhage with warfarin among Asians, there is little published data on dabigatran to assess 'real world' efficacy and safety of dabigatran therapy in Asia. This was a retrospective observational study of patients prescribed dabigatran between 2010 and 2013.

View Article and Find Full Text PDF

Treatment with thalidomide is associated with vascular thrombosis. The effect of thalidomide on platelet activation is unclear, although the use of aspirin is justified for thromboprophylaxis. A study on platelet activation markers was done among multiple myeloma patients receiving thalidomide therapy with warfarin as thromboprophylaxis.

View Article and Find Full Text PDF

Background: Right ventricular apical (RVA) pacing is associated with adverse left ventricular (LV) remodeling and biventricular (BiV) pacing may prevent it although the mechanisms remain unclear. The current study aimed to assess the role of early pacing-induced systolic dyssynchrony (DYS) to predict adverse LV remodeling.

Methods: Patients with standard pacing indications and normal LV ejection fraction were randomized either to BiV (n=89) or RVA pacing (n=88).

View Article and Find Full Text PDF

Aims: The Pacing to Avoid Cardiac Enlargement (PACE) trial is a prospective, double-blinded, randomized, multicentre study that reported the superiority of biventricular (BiV) pacing to right ventricular apical (RVA) pacing in the prevention of left ventricular (LV) adverse remodelling and deterioration of systolic function at 1 year. In the current analysis, we report the results at extended 2-year follow-up for changes in LV function and remodelling.

Methods And Results: Patients (n = 177) with bradycardia and preserved LV ejection fraction (EF ≥45%) were randomized to receive RVA or BiV pacing.

View Article and Find Full Text PDF

Background: Observational studies suggest that conventional right ventricular apical pacing may have a deleterious effect on left ventricular function. In this study, we examined whether biventricular pacing is superior to right ventricular apical pacing in preventing deterioration of left ventricular systolic function and cardiac remodeling in patients with bradycardia and a normal ejection fraction.

Methods: In this prospective, double-blind, multicenter study, we randomly assigned 177 patients in whom a biventricular pacemaker had been successfully implanted to receive biventricular pacing (89 patients) or right ventricular apical pacing (88 patients).

View Article and Find Full Text PDF

Background: Deleterious effect on left ventricular (LV) function was observed with conventional right ventricular apical (RVA) pacing. Preliminary data suggested that biventricular pacing (BiV) may be superior to RVA pacing in patients with LV systolic dysfunction. However, the optimal pacing mode and site(s) for patients with normal LV systolic function remain controversial.

View Article and Find Full Text PDF

Coronary sinus perforation is a relatively uncommon but much feared complication that may occur during the placement of left ventricular pacing lead. Coronary sinus perforation, especially in the presence of an obstructive flap, usually indicates the need to abandon the implantation attempt, as there are difficulties in crossing the obstructive flap as well as uncertainty of whether the lead is in the true lumen or into the pericardial space. We describe our experience in successfully placing the left ventricular lead safely despite the problems arising from these circumstances.

View Article and Find Full Text PDF

Background: The normal sinus pacemaker complex is an extensive structure within the right atrium. We hypothesized that patients with sinus node disease (SND) would have evidence of diffuse atrial abnormalities.

Methods And Results: Sixteen patients with symptomatic SND and 16 age-matched controls were studied.

View Article and Find Full Text PDF

Background: The objective of this study was to describe the electrophysiological characteristics, anatomic distribution, and long-term outcome after focal ablation (RFA) of pulmonary vein (PV) atrial tachycardia (AT). Both atrial fibrillation (AF) and AT may be due to a rapidly firing focus in the PVs. Whether these represent two aspects of the same process is unknown.

View Article and Find Full Text PDF

Objectives: The study was done to characterize the electrocardiographic and electrophysiologic features of focal atrial tachycardia originating at the mitral annulus (MA).

Background: Though the majority of left atrial tachycardias originate around the ostia of the pulmonary veins, only isolated reports have described focal tachycardia originating from the MA.

Methods: Seven patients of a consecutive series of 172 patients undergoing radiofrequency ablation for focal atrial tachycardia are reported.

View Article and Find Full Text PDF

We report the case of an accessory pathway in a left inferoposterior diverticulum. The pathway masqueraded as a true left lateral pathway due to the direction of activation over a coronary sinus to left atrium connection. The patient had undergone four prior failed ablation attempts at other institutions using both a transseptal and retrograde approach.

View Article and Find Full Text PDF