Background: A composite, peripheral gene expression score based on quantitative RNA-measurements has been validated for detecting stenosis against invasive coronary X-ray angiography. IVUS/VH has been validated for quantitative measurements of coronary plaque volume and composition and has been shown to be predictive of outcomes and treatment effects. The correlation between peripheral gene expression and coronary plaque composition by intravascular ultrasound with radiofrequency backscatter (IVUS/VH) is unknown.
View Article and Find Full Text PDFBackground: Apoprotein B-containing lipoproteins are atherogenic, but atheroprotective functions of apoprotein A-containing high-density lipoprotein (HDL) particles are poorly understood. The association between lipoproteins and plaque components by coronary computed tomography angiography (CTA) and intravascular ultrasound with radiofrequency backscatter (IVUS/VH) has not been evaluated.
Methods And Results: Quantitative, 3-dimensional plaque measurements were performed in 60 patients with CTA and IVUS/VH.
Am J Cardiol
January 2014
The objective of this study was to compare the diagnostic accuracy of quantitative coronary angiography (QCA), coronary computed tomography angiography (CTA), and intravascular ultrasound (IVUS) with fractional flow reserve (FFR) measurements. Eighty-five lesions (40% to 99% diameter stenosis) in 85 patients were prospectively interrogated by QCA, CTA, IVUS, and FFR. Minimal lumen diameter (MLD), percent diameter stenosis (%DS), minimal lumen area (MLA), and percent area stenosis (%AS) were measured.
View Article and Find Full Text PDFJ Cardiovasc Transl Res
October 2013
Whether quantitative, two-dimensional, and three-dimensional plaque measurements by intravascular ultrasound with radiofrequency backscatter (IVUS/VH) are different between intermediate lesions with or without major adverse cardiovascular events (MACE) is unknown. IVUS/VH-derived parameters were compared in 60 patients with an intermediate coronary lesion (40-70 %) between lesions that did or did not result in MACE over 12 months. IVUS/VH measurements were done at the site of the minimal lumen area (MLA) and on a per-plaque basis, defined by 40 % plaque burden.
View Article and Find Full Text PDFObjectives: This study sought to determine the accuracy of 3-dimensional, quantitative measurements of coronary plaque by computed tomography angiography (CTA) against intravascular ultrasound with radiofrequency backscatter analysis (IVUS/VH).
Background: Quantitative, 3-dimensional coronary CTA plaque measurements have not been validated against IVUS/VH.
Methods: Sixty patients in a prospective study underwent coronary X-ray angiography, IVUS/VH, and coronary CTA.
Background: The whole-heart coronary artery calcium (CAC) score has poor predictive value for obstructive coronary artery disease (CAD). We hypothesized that vessel- and lesion-specific CAC scores are more accurate.
Objectives: To evaluate the usefulness of vessel- and lesion-specific CAC in predicting obstructive CAD and to assess the incremental value added by the vessel- and lesion-specific CAC to the conventional whole-heart CAC approach.
The dataset obtained with 64-slice multidetector CT (MDCT) for coronary artery evaluation can be used to calculate important left ventricular (LV) volumetric parameters. We compared LV parameters derived by new, commercially available, fully automated software for MDCT (Syngo Circulation, Siemens, Germany) to cardiac magnetic resonance (CMR) as a reference standard. Twenty patients underwent CMR after completing a clinically indicated MDCT.
View Article and Find Full Text PDF