A crystalline-fiber-based Mirau-type full-field optical coherence tomography (FF-OCT) system utilizing two partially coherent illumination modes is presented. Using a diode-pumped Ti:sapphire crystalline fiber with a high numerical aperture, spatially-incoherent broadband emission can be generated with high radiance. With two modes of different spatial coherence settings, either deeper penetration depth or higher B-scan rate can be achieved.
View Article and Find Full Text PDFCompared with the industry standard MTF consequential testing result, the full field transmitted wavefront testing is more analytical for field aberration analysis. A novel wavefront measuring device specialized for the miniature lens testing application is developed to measure the full field aberration in a high resolution of 35x36 radial-azimuthal fields. The device adapts the high dynamic range Shack-Hartman wavefront sensor to minimize the alignment uncertainty induced from collimator under high field angle.
View Article and Find Full Text PDFThe vibration modulated stitching interferometry acquires many subaperture phases timely forming the high overlapping density subapertures for asphere phase stitching. The large number of overlapping subapertures had been proven effective in suppressing the reference error. In this research, we propose a pixel-by-pixel reference calibration method by using the averaged difference between the stitched phase and compensated phase within the overlapping subapertures.
View Article and Find Full Text PDFThe subaperture stitching interferometer is a flexible testing device that measures either high-numerical-aperture or large aperture optics without the requirement of additional auxiliary optics. In the measurement, the interferometer reference optics error can contaminate the stitched phase of the complete tested optics and reduce measurement accuracy. We propose high-overlapping-density subaperture stitching interferometry (HOD-SSI) to reduce the impact of reference optics errors on the stitched phase.
View Article and Find Full Text PDFThe vibration-modulated subaperture stitching interferometer acquires the interferogram on the fly dynamically. With its highly improved measurement throughput, we applied the device for high overlapping density subaperture stitching interferometry to acquire hundreds of overlapping subapertures in a single phase stitching measurement. The averaging effect of the high overlapping density stitching interferometer is discussed.
View Article and Find Full Text PDFA novel subaperture stitching interferometry is developed to measure the surface deformation of the lens by utilizing the mechanical vibration induced from a motorized stage. The interferograms of different subapertures are acquired on the fly while the tested optics is rotating against its symmetrical axis. The measurement throughput and the subaperture positioning accuracy are improved simultaneously by adopting both the synchronous rotational scanning mechanism and the non-uniform phase shifting algorithm.
View Article and Find Full Text PDF