Publications by authors named "Humberto Gennari Filho"

Background: The aim of this systematic review is to evaluate the relationship between two methods used to assess implant stability, investigating whether both provide similar implant stability assessments for the same clinical case.

Methods: A literature search was conducted on MEDLINE-PubMed and Scopus databases, without limitation of the publication period, up to November 2015. The following key words were used, with associations among them: "dental implant," "dental implants," "Osstell," "resonance frequency analysis," "implant stability quotient," "ISQ," "Periotest," "Periotest value," and "PTV.

View Article and Find Full Text PDF

Introduction: The use of removable partial denture (RPD) is considered as low-cost and common treatment option to rehabilitate edentulous areas.

Aim: This study aimed to investigate the epidemiological data of patients rehabilitated with removable partial denture (RPD) in order to assess treatment survival rate and failures.

Materials And Methods: Epidemiological data and medical records of patients treated with RPD between 2007 and 2012 at the RPD discipline of a Brazilian University (Aracatuba Dental School- UNESP) were evaluated as well as dental records of patients who underwent RPD treatments (fabrication or repairs) between 2000 and 2010.

View Article and Find Full Text PDF

The aim of this study was to evaluate the stress distribution on full-arch prostheses, considering axial implants and tilted implants with or without abutments. Two photoelastic models were made, being that in 1 model the implants were inserted perpendicular, whereas in the other model 2 implants were inserted perpendicular and 2 implants were inserted with tilting 30° to the distal area. The prosthetic situations were evaluated: A-axial implants and nonsegmented full-arch prosthesis; B-axial implants and segmented full-arch prosthesis; C-tilted distal implants and nonsegmented full-arch prosthesis; D-tilted distal implants and segmented full-arch prosthesis, and was applied an axial load of 100 N at 5 points.

View Article and Find Full Text PDF

Photoelastic analysis was used to evaluate the biomechanical behaviour of implant-supported, double-screwed crowns with different connection systems and cantilever lengths. Three models were made in PL-2 photoelastic resin and divided into six groups, on the basis of the implant connection system (external hexagon [EH] or Morse taper [MT]), type of abutment (Mini Pilar [Neodent, Curitiba, Paraná, Brazil] or "UCLA") and number of crowns in the cantilever (one or two). The implant-prosthesis unit was placed in a circular polariscope.

View Article and Find Full Text PDF

The purpose of this literature review was to describe the main features of phantom eye syndrome in relation to their possible causes, symptoms, treatments, and influence of eye amputation on quality of life of anophthalmic patients. For this, a bibliographical research was performed in Pubmed database using the following terms: "eye amputation," "eye trauma," "phantom eye syndrome," "phantom pain," and "quality of life," associated or not. Thirteen studies were selected, besides some relevant references contained in the selected manuscripts and other studies hallowed in the literature.

View Article and Find Full Text PDF

Purpose: This study aimed to investigate the etiology, clinical manifestations, and treatment options of dental implants fractures through a literature review and to relate a clinical report.

Methods: A literature review was performed using the Medline database and this paper describes a case demonstrating the management of implant fracture. Twenty two articles were selected in the present literature review.

View Article and Find Full Text PDF

Because the biomechanical behavior of dental implants is different from that of natural tooth, clinical problems may occur. The mechanism of stress distribution and load transfer to the implant/bone interface is a critical issue affecting the success rate of implants. Therefore, the aim of this study was to conduct a brief literature review of the available stress analysis methods to study implant-supported prosthesis loading and to discuss their contributions in the biomechanical evaluation of oral rehabilitation with implants.

View Article and Find Full Text PDF

Background: Although the long-term success of implant treatment has been well- established, failures can still occur and the smoking habit has been reported as a risk factor for implant loss. A literature review on the effects of smoking on the survival of dental implants was undertaken.

Methods And Results: Medline database was used to carry out the review with the keywords "osseointegration", "smoking" and "bone healing".

View Article and Find Full Text PDF

Background: Amputations affect both the physical and the psychological aspects of an individual, causing significant impact on self-esteem. The main causes of finger amputations are work-related accidents with dangerous machinery, road traffic accidents, and animal bites, as well as systemic diseases such as diabetes. This report aims to describe a simple technique for fabrication of implant-retained finger prosthesis with a modified base of the retention system.

View Article and Find Full Text PDF

The purposes of this study were to photoelastically measure the biomechanical behavior of 4 implants retaining different cantilevered bar mandibular overdenture designs and to compare a fixed partial denture (FPD). A photoelastic model of a human edentulous mandible was fabricated, which contained 4 screw-type implants (3.75 × 10 mm) embedded in the parasymphyseal area.

View Article and Find Full Text PDF

Esthetics is important for success of implant-supported prostheses. This study aimed to review esthetics concepts for implant treatment. Research in the PubMed database included studies published from 1995 to 2010 with the keywords implant esthetics, implant-supported prostheses, and esthetics.

View Article and Find Full Text PDF

Objective: The purpose of this study was to compare the dental movement that occurs during the processing of maxillary complete dentures with 3 different base thicknesses, using 2 investment methods, and microwave polymerization.

Methods: A sample of 42 denture models was randomly divided into 6 groups (n = 7), with base thicknesses of 1.25, 2.

View Article and Find Full Text PDF

Unlabelled: The use of ocular prostheses for ophthalmic patients aims to rebuild facial aesthetics and provide an artificial substitute to the visual organ. Natural intemperate conditions promote discoloration of artificial irides and many studies have attempted to produce irides with greater chromatic paint durability using different paint materials.

Objectives: The present study evaluated the color stability of artificial irides obtained with two techniques (oil painting and digital image) and submitted to microwave polymerization.

View Article and Find Full Text PDF

Because of the widespread use of implant-supported restorations and that the success of this treatment depends on the passivity of the different component systems of implant-prosthesis, a literature review was performed to highlight issues related to passivity in framework of implant-supported fixed prosthesis. A search of English-language peer-review literature was completed using MEDLINE database (PubMed) focusing on acceptable levels of passivity, misfit classification, problems related to misfit, methods to evaluate misfit, general factors that affect the passivity, and the biologic tolerance in the presence of misfit. The information obtained in the present review suggested that even if it is hard to obtain an implant-supported prosthesis with complete passivity, the professional should use the technological resources to offer better conditions for their patients.

View Article and Find Full Text PDF

The demand for aesthetic restorations has increased during the last years. Dental ceramics are a successful alternative for some cases because of aesthetics and biocompatibility. Therefore, the aim of this literature review was to present the factors necessary to fabricate all-ceramic restorations with aesthetics similar to natural dentition.

View Article and Find Full Text PDF

The aim of this study was to evaluate the biomechanical behavior of a mandibular distal extension removable partial denture (DERPD) associated with an implant and different retention system, by bidimensional finite element method. Five hemimandible models with a canine and external hexagon implant at second molar region associated with DERPD were simulated: model A, hemimandible with a canine and a DERPD; model B, hemimandible with a canine and implant with a healing abutment associated to a DERPD; model C, hemimandible with a canine and implant with an ERA attachment associated to a DERPD; model D, hemimandible with a canine and implant with an O'ring attachment associated to a DERPD; and model E, hemimandible with a canine and implant-supported prosthesis associated to a DERPD. Cusp tips were loaded with 50 N of axial or oblique force (45 degrees).

View Article and Find Full Text PDF

During the process of facial rehabilitation, the mobility of ocular prostheses must be considered. Whereas some factors depend exclusively on the dentist, such as molding techniques and selection of material for denture construction, regarding ocular rehabilitation, factors, such as type of surgery, whether to adopt implants, and the use of lubricants, deserve special attention owing to their integration and their association with other factors pertaining exclusively to the patient. To establish harmony, and with the intention of aiding the dentist, after a discerning evaluation, the authors of this study report the factors that provide greater or less mobility to ocular prostheses and conceal the prosthesis in a more natural way, thereby contributing toward achieving a favorable aesthetic result in rehabilitations.

View Article and Find Full Text PDF

Objective: This study investigated the efficacy of different techniques for the union of fragments of a denture before repair and on the accuracy of the reposition.

Materials And Methods: For this study, 20 maxillary dentures made with Lucitone 550 heat-cured resin were used. Points were determined with a scanner on the cusp of the teeth, as a measurement of the segments.

View Article and Find Full Text PDF

Cancer is regarded as abnormal cellular multiplication; it is not controlled by the organism, and its cells present a differentiated DNA. Initially, the disease does not show clinical signs, but it can be diagnosed by laboratory examinations. When tumors are present in the maxillofacial area, the carrier can lose structures in this area, resulting to the carrier's social environment exclusion.

View Article and Find Full Text PDF

Objectives: The objective of this study was to evaluate by a visual method of comparison the color stability of nonpigmented and pigmented facial silicones after accelerated aging.

Materials And Methods: Two kinds of silicones were used in this study; one specifically formulated for facial prostheses and the other an acetic silicone for industrial use. Twenty-four trial bodies were made for each silicone.

View Article and Find Full Text PDF

The technique presented in this article presents a protocol for treatment that reduces the time required for the fabrication and placement of an implant supported prosthesis. It also offers improved patient comfort at a lower cost when compared to conventional technology.

View Article and Find Full Text PDF

The purpose of this study was to present a literature review about photoelasticity, a laboratory method for evaluation of implants prosthesis behavior. Fixed or removable prostheses function as levers on supporting teeth, allowing forces to cause tooth movement if not carefully planned. Hence, during treatment planning, the dentist must be aware of the biomechanics involved and prevent movement of supporting teeth, decreasing lever-type forces generated by these prosthesis.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to compare the artificial tooth positional changes following the flasking and polymerization of complete dentures by a combination of two flasking methods and two polymerization techniques using computer graphic measurements.

Materials And Methods: Four groups of waxed complete dentures (n = 10) were invested and polymerized using the following techniques: (1) adding a second investment layer of gypsum and conventional water bath polymerization (Control), (2) adding a second investment layer of gypsum and polymerization with microwave energy (Gypmicro), (3) adding a second investment layer of silicone (Zetalabor) and conventional polymerization (Silwater), and (4) adding a second investment layer of silicone and polymerization with microwave energy (Silmicro). For each specimen, six segments of interdental distances (A to F) were measured to determine the artificial tooth positions in the waxed and polymerized stages using software program AutoCad R14.

View Article and Find Full Text PDF

Purpose: The aim of this study was to compare splinting techniques for impression copings of osseointegrated implants with different angulations.

Materials And Methods: Replicas (N = 24) of a metal matrix (control) containing two implants at 90 degrees and 65 degrees in relation to the horizontal surface were obtained by using four impression techniques: Technique 1 (T1), direct technique with square copings without union in open trays; Technique 2 (T2), square copings splinted with dental floss and autopolymerizing acrylic resin; Technique 3 (T3),square copings splinted with dental floss and autopolymerizing acrylic resin, sectioned and splinted again with autopolymerizing acrylic resin; Technique 4 (T4), square copings splinted with prefabricated acrylic resin bar. The impression material was polyether.

View Article and Find Full Text PDF

Purpose: The longevity of an ocular prosthesis is directly related to the resistance to erosion of its material. The purpose of this study was to evaluate the effects of chemical disinfection and the method of investment on the microhardness of ocular prosthesis acrylic resin.

Materials And Methods: Thirty-two test specimen investments were obtained in two silicones.

View Article and Find Full Text PDF