A heterodyne interferometer is developed to measure the static and temporal behaviors of birefringence of a liquid crystal variable retarder. The interferometer is designed based on the analysis of the polarization state of a coherent wave. Since the optical components of the interferometer are fixed without any adjustment, the phase retardation and the azimuthal angle of a liquid crystal variable retarder is measured independently in real time, where the environmental perturbations and common mode noises can be reduced.
View Article and Find Full Text PDFThe control of the state of polarization of a light wave for noise reduction is implemented as optical balanced detection in a common path heterodyne interferometer, which is presented in this work for measuring ellipsometric angles in real time. These angles are determined accurately in terms of quadrature interference amplitudes and phase information by maximum likelihood estimation. Thus, the interference noise is significantly reduced by the common path design associated with the optical balanced detection approach.
View Article and Find Full Text PDFWe present a double-sideband suppressed-carrier (DSB-SC) technique achieved by an optical balanced detection approach for measuring small vibrations. The baseband signal is recovered by demodulating the DSB-SC signal with a self-mixing approach without local oscillator, which is usually required in coherent detection. The achievement of carrier suppression and vibration measurement is experimentally demonstrated, and the result closely agrees with the theoretical predictions.
View Article and Find Full Text PDFWe demonstrate in this report an envelope detection technique with maximum likelihood estimation in a least square sense for determining displacement. This technique is achieved by sampling the amplitudes of quadrature signals resulted from a heterodyne interferometer so that the resolution of displacement measurement of the order of λ/10(4) is experimentally verified. A phase unwrapping procedure is also described and experimentally demonstrated and indicates that the unambiguity range of displacement can be measured beyond a single wavelength.
View Article and Find Full Text PDFAn amplitude-sensitive technique associated with a heterodyne interferometer for detecting small differential phase is reported. The excess noise with the amplitude-sensitive technique is reduced by optical subtraction instead of electronic subtraction. The differential phase introduced by the orthogonally polarized laser beams is converted to the amplitudes of two heterodyne interferometric signals, which presents amplitude and phase quadrature simultaneously.
View Article and Find Full Text PDFJ Opt Soc Am A Opt Image Sci Vis
November 2008
A differential-phase decoder (DPD) together with a polarization common-path optical heterodyne interferometer is set up. Based on this interferometric configuration and a novel balanced-detector scheme, the performance of the quantum-noise-limited differential-phase decoder is demonstrated and analyzed. The minimum-detectable differential phase is on the order of 10(-7) rad/sqrt Hz when a 2.
View Article and Find Full Text PDFA novel balanced detector interferometric ellipsometer (BDIE), composed of a polarized common-path optical heterodyne interferometer incorporating a novel balanced detector, provides an amplitude-sensitive method for measurement of the elliptical parameters of a thin film. The requirement for equal amplitude of the polarized heterodyne signals for balanced detection results in the simultaneous measurement of the elliptical parameters in terms of the azimuth angle of a half-wave plate and the output intensity from the differential amplifier, respectively. The common-path feature of BDIE shows a common phase noise rejection mode and this enhances the sensitivity of the phase measurement.
View Article and Find Full Text PDFA novel technique that measures the linear birefringence of crystal quartz within the configuration of a Soliel-Babinet compensator (SBC) is proposed. A characteristic of this technique is that phase retardation introduced by quartz is amplitude modulation (AM) instead of phase modulation (PM). The linear birefringence is measured regardless of the azimuth angle of the SBC and the orientation of the linear polarization laser beam.
View Article and Find Full Text PDF