The recycling of polyethylene terephthalate (PET) stands as an effective strategy for mitigating plastic pollution and reducing resource waste. The study aimed to investigate the characterization and elimination efficiency of volatile organic compounds (VOCs) present in rPET at various recycling stages using comprehensive two-dimensional gas chromatography-quadrupole-time-of-flight-mass spectrometry coupled with chemometrics. The results revealed that 52, 135, 95, 44, and 33 VOCs, mostly classified into three chemical groups, were tentatively identified in virgin - PET (v-PET), cold water washed - rPET (C-rPET), decontaminated - rPET (D-rPET), melt-extruded - rPET (M-rPET), and solid-state polycondensation - rPET (S-rPET), respectively.
View Article and Find Full Text PDFA comprehensive understanding of the molecular mechanisms underlying microbial catabolism of dibutyl phthalate (DBP) is still lacking. Here, we newly isolated a bacterial strain identified as Pseudomonas aeruginosa PS1 with high efficiency of DBP degradation. The degradation ratios of DBP at 100-1000 mg/L by this strain reached 80-99 % within 72 h without a lag phase.
View Article and Find Full Text PDFRecycled PET (rPET) is gaining popularity for use in the production of new food contact materials (FCMs) under the context of circular economy. However, the limited information on contaminants in rPET from China and concerns about their potential risk are major obstacles to their use in FCM in China. Fifty-five non-volatile compounds were tentatively identified in 126 batches of hot-washed rPET flakes aimed for food packaging applications in China.
View Article and Find Full Text PDFFood Addit Contam Part A Chem Anal Control Expo Risk Assess
November 2023
The objective was to establish a robust and reliable approach for the characterisation of volatile organic compounds (VOCs) present in food contact paperboard. This was achieved through the utilisation of headspace solid-phase microextraction in tandem with comprehensive two-dimensional (2D) gas chromatography (GC) and quadrupole time-of-flight mass spectrometry (HS-SPME-GC × GC-QTOF-MS). The experimental parameters were optimised, involving the use of a DVB/C-WR/PDMS fibre at a temperature of 80 °C for a duration of 30 min.
View Article and Find Full Text PDFFood Addit Contam Part A Chem Anal Control Expo Risk Assess
August 2023
Plastic packaging waste, such as polyethylene terephthalate (PET) has increased significantly in recent decades, arousing a considerable and serious public concern regarding the environment, economy, and policy. Plastic recycling is a useful tool to mitigate this issue. Here, a feasible study was performed to investigate the potential of a novel method for identifying virgin and recycled PET.
View Article and Find Full Text PDFFood Addit Contam Part A Chem Anal Control Expo Risk Assess
March 2023
Due to recently introduced 'so-called' bio- and plant-based friendly food contact materials and articles (FCM/FCA), some neglected safety issues need to be raised. In this review, potential chemical contaminants from FCM/FCA made from or containing wood and bamboo are presented. Sources, migration, and analytical issues in determining contaminants including intentionally and non-intentionally added substances (IAS and NIAS, respectively) are reviewed.
View Article and Find Full Text PDFFood Addit Contam Part A Chem Anal Control Expo Risk Assess
February 2023
Plastic take-out food containers may release microplastics (MPs) into food and pose a potential risk to food safety and human health. Here, after being subjected to hot water treatment, MPs released from three types of plastic food containers (polypropylene, PP; polyethylene, PE; expanded polystyrene, EPS) were identified by micro-Raman spectroscopy. The results showed that the size of released MPs ranged from 0.
View Article and Find Full Text PDFA comparison was performed on various methods detecting the volatile contaminants (VCs) in recycled poly(ethylene terephthalate) (rPET) flakes, the results demonstrated that head-space solid phase micro-extraction combined with comprehensive two-dimensional gas chromatograph-tandem quadrupole-time-of-flight mass spectrometry (HS-SPME-GC×GC-QTOF-MS) was a sensitive, effective, accurate method, and successfully applied to analyze 57 rPET flakes collected from different recycling plants in China. A total of 212 VCs were tentatively identified, and the possible source were associated with plastic, food, and cosmetics. 45 VCs are classified as high-priority compounds with toxicity level IV or V and may pose a risk to human health.
View Article and Find Full Text PDFA growing attention is attracted to the use of recycled plastics as food contact materials, and its chemical safety research and discrimination approach are indispensable. In current study, ultraviolet-visible spectrometry (UV-Vis) and ultra-performance liquid chromatography quadrupole time-of-flight mass spectrometry (UPLC-Q-TOF-MS) were used to provide spectral and mass fingerprinting for polyethylene (PE). Coupling with chemometrics, two methods were developed to discriminate recycled and virgin PE.
View Article and Find Full Text PDFFood Addit Contam Part A Chem Anal Control Expo Risk Assess
December 2021
Food Addit Contam Part A Chem Anal Control Expo Risk Assess
May 2021
To determine the occurrence of mineral oil hydrocarbons (MOH) in food contact papers in China, and to investigate the potential sources of MOH contamination, a total of 159 food contact papers and raw materials were analysed by off-line solid-phase extraction-gas chromatography flame ionisation detection (SPE-GC-FID) and a GC-MS method. The migration of MOH from food contact papers into Tenax, olive oil or 50% ethanol under the worst foreseeable conditions of use was determined. The results indicated that the occurrence of MOH in China is of a potential health risk concerning the migration of mineral oil saturated hydrocarbons (MOSH) and mineral oil aromatic hydrocarbons (MOAH) which were detected in 82.
View Article and Find Full Text PDFAtmospheric pressure gas chromatography (APGC) coupled to quadrupole time-of-flight (QTOF) and electron ionization mass spectrometry together with commercial library search are two complementary techniques for non-target screening of volatile and semi-volatile compounds. Optimization was first conducted to achieve easier search of correspondent peaks between the two systems. Analytical strategy for the determination of volatile and semi-volatile compound with different identification confidence levels was then proposed and applied to food contact grade polypropylene (PP) samples.
View Article and Find Full Text PDFFood Addit Contam Part A Chem Anal Control Expo Risk Assess
November 2016
Three nanocopper/low-density polyethylene (LDPE) composite films were tested in food simulants (3% acetic acid and 10% ethanol) and real food matrices (rice vinegar, bottled water and Chinese liquor) to explore the behaviours of copper migration using ICP-OES and GFAAS. The effects of exposure time, temperature, nanocopper concentration and contact media on the release of copper from nanocopper/LDPE composite films were studied. It was shown that the migration of copper into 10% ethanol was much less than that into 3% acetic acid at the same conditions.
View Article and Find Full Text PDFFood Addit Contam Part A Chem Anal Control Expo Risk Assess
May 2015
An analytical method based on ICP-MS was developed for the determination of Ti in food simulants (3% (w/v) aqueous acetic acid and 50% (v/v) aqueous ethanol). The method was used to determine the migration of Ti from nano-TiO₂-PE films used for food packaging into food simulants under different temperature and migration time conditions. The maximum migration amounts into 3% (w/v) aqueous acetic acid were 1.
View Article and Find Full Text PDFNan Fang Yi Ke Da Xue Xue Bao
January 2006
Objective: To determine organochlorine pesticide residue in 9 Chinese herbs.
Methods: The organochlorine pesticides were extracted from the herbs with mixed solvents of n-hexane and acetone by a solid-phase extraction cartridge Florisil. Capillary gas chromatography was used to separate the samples.