This study is to optimize the multi-quality performance of magnetic catalyst/ozone process by combining a technique for order performance by similarity to ideal solution (TOPSIS) with the Taguchi method, which simultaneously has the best decomposition rate constant of benzoic acid and removal rate constant of total organic carbon (TOC). The optimal experimental parameters were pH of 7, initial concentration of 75 ppm and catalyst loading of 0.05 g/L.