Publications by authors named "Hoyeon Lee"

In radiation-based medical imaging research, computational modeling methods are used to design and validate imaging systems and post-processing algorithms. Monte Carlo methods are widely used for the computational modeling as they can model the systems accurately and intuitively by sampling interactions between particles and imaging subject with known probability distributions. This article reviews the physics behind Monte Carlo methods, their applications in medical imaging, and available MC codes for medical imaging research.

View Article and Find Full Text PDF

This study reports intrinsic multimodal memristivity of a nonconjugated radical polymer with ambient stability. Organic memristive devices represent powerful candidates for biorealistic data storage and processing. However, there exists a substantial knowledge gap in realizing the synthetic biorealistic systems capable of effectively emulating the cooperative and multimodal activation processes in biological systems.

View Article and Find Full Text PDF

Introduction: We developed and externally validated a fully automated algorithm using deep learning to detect large vessel occlusion (LVO) in computed tomography angiography (CTA).

Method: A total of 2,045 patients with acute ischemic stroke who underwent CTA were included in the development of our model. We validated the algorithm using two separate external datasets: one with 64 patients (external 1) and another with 313 patients (external 2), with ischemic stroke.

View Article and Find Full Text PDF

Purpose: In radiotherapy (RT) for brain tumors, patient heterogeneity masks treatment effects, complicating the prediction and mitigation of radiation-induced brain necrosis. Therefore, understanding this heterogeneity is essential for improving outcome assessments and reducing toxicity.

Experimental Design: We developed a clinically practical pipeline to clarify the relationship between dosimetric features and outcomes by identifying key variables.

View Article and Find Full Text PDF

To experimentally validate two online adaptive proton therapy (APT) workflows using Gafchromic EBT3 films and optically stimulated luminescent dosimeters (OSLDs) in an anthropomorphic head-and-neck phantom.A three-field proton plan was optimized on the planning CT of the head-and-neck phantom with 2.0 Gy(RBE) per fraction prescribed to the clinical target volume.

View Article and Find Full Text PDF

. To allow the estimation of secondary cancer risks from radiation therapy treatment plans in a comprehensive and user-friendly Monte Carlo (MC) framework..

View Article and Find Full Text PDF

Objectives: In this functional magnetic resonance imaging study, we aimed to investigate the differences in brain activation between individuals with autism spectrum disorder (ASD) and typically developing (TD) individuals during perspective taking. We also examined the association between brain activation and empathic and interoceptive abilities.

Methods: During scanning, participants from the ASD (n=17) and TD (n=22) groups were shown pain stimuli and asked to rate the level of the observed pain from both self- and other-perspectives.

View Article and Find Full Text PDF

Induced pluripotent stem cell (iPSC)-derived cardiac organoids offer a versatile platform for personalized cardiac toxicity assessment, drug screening, disease modeling, and regenerative therapies. While previous image-based contractility analysis techniques allowed the assessment of contractility of two-dimensional cardiac models, they face limitations, including encountering high noise levels when applied to three-dimensional organoid models and requiring expensive equipment. Additionally, they offer fewer functional parameters compared to commercial software.

View Article and Find Full Text PDF

Purpose: To demonstrate the suitability of optically stimulated luminescence detectors (OSLDs) for accurate simultaneous measurement of the absolute point dose and dose-weighted linear energy transfer (LET) in an anthropomorphic phantom for experimental validation of daily adaptive proton therapy.

Methods: A clinically realistic intensity-modulated proton therapy (IMPT) treatment plan was created based on a CT of an anthropomorphic head-and-neck phantom made of tissue-equivalent material. The IMPT plan was optimized with three fields to deliver a uniform dose to the target volume covering the OSLDs.

View Article and Find Full Text PDF

We present a 320 × 240 CMOS image sensor (CIS) using the proposed hybrid-correlated multiple sampling (HMS) technique with an adaptive dual-gain analog-to-digital converter (ADC). The proposed HMS improves the noise characteristics under low illumination by adjusting the ADC gain according to the incident light on the pixels. Depending on whether it is less than or greater than 1/4 of the full output voltage range from pixels, either correlated multiple sampling or conventional-correlated double sampling (CDS) is used with different slopes of the ramping signals.

View Article and Find Full Text PDF

The mTOR signaling pathway integrates signaling inputs from nutrients, including glucose and amino acids, which are precisely regulated by transporters depending on nutrient levels. The L-type amino acid transporter 1 (LAT1) affects the activity of mTORC1 through upstream regulators that sense intracellular amino acid levels. While mTORC1 activation by LAT1 has been thoroughly investigated in cultured cells, the effects of LAT1 expression on the activity of mTORC2 has scarcely been studied.

View Article and Find Full Text PDF

Purpose: This work evaluates an online adaptive (OA) workflow for head-and-neck (H&N) intensity-modulated proton therapy (IMPT) and compares it with full offline replanning (FOR) in patients with large anatomical changes.

Methods: IMPT treatment plans are created retrospectively for a cohort of eight H&N cancer patients that previously required replanning during the course of treatment due to large anatomical changes. Daily cone-beam CTs (CBCT) are acquired and corrected for scatter, resulting in 253 analyzed fractions.

View Article and Find Full Text PDF

. The TOol for PArticle Simulation (TOPAS) is a Geant4-based Monte Carlo software application that has been used for both research and clinical studies in medical physics. So far, most users of TOPAS have focused on radiotherapy-related studies, such as modeling radiation therapy delivery systems or patient dose calculation.

View Article and Find Full Text PDF

Circadian rhythms and sleep homeostasis constitute the two-process model for daily sleep regulation. However, evidence for circadian control of sleep-wake cycles has been relatively short since clock-less animals often show sleep behaviors quantitatively comparable to wild-type. Here we examine sleep behaviors under different light-dark regimes and demonstrate that circadian clocks gate light-induced arousal.

View Article and Find Full Text PDF

Background: Diagnostic performance based on x-ray breast imaging is subject to breast density. Although digital breast tomosynthesis (DBT) is reported to outperform conventional mammography in denser breasts, mass detection and malignancy characterization are often considered challenging yet.

Purpose: As an improved diagnostic solution to the dense breast cases, we propose a dual-energy DBT imaging technique that enables breast compositional imaging at comparable scanning time and patient dose compared to the conventional single-energy DBT.

View Article and Find Full Text PDF

Recent studies have shown that the ability to process number in the face of conflicting dimensions of magnitude is a crucial aspect of numerosity judgments, relying in part on the inhibition of the non-numerical dimensions. Here we report, for the first time, that these inhibitory control processes are specific to the conflicting dimension of magnitude. Using a non-symbolic numerical comparison task adapted to a conflict adaptation paradigm on a group of 82 adults, we show that congruency effects between numerical and non-numerical information were reduced only when the conflicting dimension was the same in the preceding incongruent trial.

View Article and Find Full Text PDF

To establish an open framework for developing plan optimization models for knowledge-based planning (KBP).Our framework includes radiotherapy treatment data (i.e.

View Article and Find Full Text PDF

Monte Carlo (MC) codes are increasingly used for accurate radiotherapy dose calculation. In proton therapy, the accuracy of the dose calculation algorithm is expected to have a more significant impact than in photon therapy due to the depth-dose characteristics of proton beams. However, MC simulations come at a considerable computational cost to achieve statistically sufficient accuracy.

View Article and Find Full Text PDF
Article Synopsis
  • * Researchers analyzed single-cell RNA profiles from both healthy control mice and those with doxorubicin-induced RPE senescence, identifying 4 main subpopulations in the control RPE with distinct biological functions.
  • * In mice with RPE senescence, significant changes were noted in a specific cell cluster associated with catalytic activity, along with altered expressions of 6 previously unlinked genes across 4 clusters, offering new insights into RPE senescence.
View Article and Find Full Text PDF

(Antarctic krill) serine protease (ESP) was investigated to gain insights into the activity-structural relationship, folding behavior, and regulation of the catalytic function. We purified ESP from the krill muscle and characterized biochemical distinctions via enzyme kinetics. Studies of inhibition kinetics and unfolding in the presence of a serine residue modifier, such as phenylmethanesulfonyl fluoride, were conducted.

View Article and Find Full Text PDF

Ras homologous A (RHOA), a signal mediator and a GTPase, is known to be associated with the progression of gastric cancer (GC), which is the fourth most common cause of death in the world. Previously, we designed pharmacologically optimized inhibitors against RHOA, including JK-136 and JK-139. Based on this previous work, we performed lead optimization and designed novel RHOA inhibitors for greater anti-GC potency.

View Article and Find Full Text PDF

Background: Digital breast tomosynthesis (DBT) is a technique that can overcome the shortcomings of conventional X-ray mammography and can be effective for the early screening of breast cancer. The compression of the breast is essential during the DBT imaging. However, since the periphery of the breast cannot be compressed to a constant value, nonuniformity of thickness and in-plane shape variation happen.

View Article and Find Full Text PDF

Simplifying assays while maintaining the robustness of reagents is a challenge in diagnostics. This problem is exacerbated when translating quality diagnostic assays to developing countries that lack resources and infrastructure such as trained health workers, high-end equipment, and cold-chain systems. To solve this problem, in this study, a simple solution that films assay reagents to simplify the operation of diagnostic assays and preserve the stability of diagnostic reagents without using cold chains is presented.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Notice

Message: fwrite(): Write of 34 bytes failed with errno=28 No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 272

Backtrace:

A PHP Error was encountered

Severity: Warning

Message: session_write_close(): Failed to write session data using user defined save handler. (session.save_path: /var/lib/php/sessions)

Filename: Unknown

Line Number: 0

Backtrace: