TauroH-23-(Se) selena-25-homocholic acid retention values are used in the diagnosis of bile acid malabsorption. The standard method for measuring values is with an uncollimated gamma camera, which can create some logistic difficulties, with other background sources of activity, which are irrelevant when a collimator is used, becoming significant. In this study we compare the retention values obtained with a collimated and an uncollimated gamma camera in phantoms and in 23 patients.
View Article and Find Full Text PDFDimercaptosuccinic acid imaging is the 'gold standard' for the detection of cortical defects and diagnosis of scarring of the kidneys. The Siemens planar processing package, which implements adaptive noise reduction using the Pixon algorithm, is designed to allow a reduction in image noise, enabling improved image quality and reduced acquisition time/injected activity. This study aimed to establish the level of improvement in image quality achievable using this algorithm.
View Article and Find Full Text PDFPurpose: The purpose of this study was to show the viability and performance of a shape-based pattern recognition technique applied to I-N-omega-fluoropropyl-2-beta-carbomethoxy-3beta-(4-iodophenyl) nortropane single-photon emission computed tomography (FP-CIT SPECT) in patients with parkinsonism.
Methods: A fully automated pattern recognition tool, based on the shape of FP-CIT SPECT images, was written using Java. Its performance was evaluated and compared with QuantiSPECT, a region-of-interest-based quantitation tool, and observer performance using receiver operating characteristic analysis and kappa statistics.
Objective: Audit Scotland has recommended that NHS boards should ensure that medical equipment performance information is used to assess whether the local area is making the best use of its medical equipment. A survey of nuclear medicine departments in Scotland was carried out to provide a benchmark.
Method: A questionnaire was sent to every nuclear medicine department in Scotland.
Background: The aim of this study was to examine the quality of nitrogen 13-labeled ammonia (NH(3)) perfusion data from coincidence-capable gamma camera positron emission tomography (GC-PET) systems compared with that from full-ring positron emission tomography (FR-PET).
Methods And Results: The performance parameters of the GC-PET system were examined and found adequate for imaging at the activity levels used clinically. We studied 15 patients who underwent stress and rest N-13-labeled NH(3) perfusion imaging on FR-PET and GC-PET systems.
Twenty seven patients with mild AD were enrolled in a prospective open label controlled study of rivastigmine. Assessments included a range of neuropsychiatric and behavioural measures and rCBF using HMPAO SPECTat baseline, three and six months. Significant enhancement of frontal, parietal and temporal brain blood flow with related psychometric improvement was observed in twelve of the treated patients.
View Article and Find Full Text PDF