Objective: Our study aims to quantitatively determine the concavity of the glenoid articular surface in patients with hypermobile shoulders compared to those without.
Method: We examined medical records of shoulder CTs from 2017 to 2022, selecting 50 patients with clinical signs of joint hypermobility for our case group and 54 for our control group. Two blinded readers independently assessed the glenoid morphology, calculating the glenoid concavity angle (GCA) and evaluating the articular surface shape as concave, flat, or convex.
To compare image quality and radiation exposure between super- and ultra-high-resolution helical and super-high-resolution volumetric CT of the temporal bone. Six cadaveric temporal bone specimens were used to evaluate key temporal bone structures using the following CT reconstruction and acquisition modes: helical and single-volume acquisition modes in super-high resolution (0.25-mm slice thickness, 1024 matrix), and helical mode in ultra-high resolution (0.
View Article and Find Full Text PDFObjectives: To evaluate the diagnostic performance of simplified post-processing approaches for quantitative wrist 4D-CT in the assessment of scapholunate instability (SLI).
Methods: A prospective monocentric case-control study included 60 patients with suspected post-traumatic scapholunate ligament (SLL) tears and persistent pain. Of these, 40 patients exhibited SLL tears, subdivided into two groups of 20 each: one group with completely torn ligaments and the other with partially torn ligaments.
Introduction: Ultrasound-guided placement of peripheral venous catheters requires appropriate equipment. Among the devices used, peripheral venous catheters have different structure and properties. This study aimed to define the impact of these different factors on the echogenicity of peripheral venous catheters.
View Article and Find Full Text PDFPurpose: The purpose of this study was to evaluate the achievable radiation dose reduction of an ultra-high resolution computed tomography (UHR-CT) scanner using deep learning reconstruction (DLR) while maintaining temporal bone image quality equal to or better than high-resolution CT (HR-CT).
Materials And Methods: UHR-CT acquisitions were performed with variable tube voltages and currents at eight different dose levels (volumic CT dose index [CTDIvol] range: 4.6-79 mGy), 1024 matrix, and 0.
Background, Aims: Stapes footplate thickness measurement using ultra-high-resolution CT has been described only in the lateral semicircular canal plane. The purpose of this study was to compare stapes footplate thickness between the lateral semicircular canal and stapes axial planes in patients with otosclerosis compared to controls.
Material And Methods: We performed a retrospective single-center study of patients undergoing high-resolution temporal bone CT.
Purpose: To describe the reliability of ultra-high-resolution computed tomography (UHR-CT) in the measurement of titanium stapes prostheses using manufacturer data as a reference.
Materials And Methods: This retrospective study included patients treated by stapedectomy with titanium prostheses who underwent UHR-CT between January 2020 and October 2023. Images were acquired using an ultra-high-resolution mode (slice thickness: 0.
Introduction: Ultrasound-guided placement of Midlines catheters (MCs) is a standard procedure with many benefits for patients. Even if there are some guidelines worldwide, this invasive technique is still taught at the patient's bed and relies on mentoring in many care centers. The performance of this care by novice practitioners raises ethical and quality of care issues mainly because of its risk of complications.
View Article and Find Full Text PDFIntroduction: Scaphotrapeziotrapezoid (STT) arthrodesis and Pyrocardan® implant for painful isolated STT osteoarthritis have shown good results, but no paper has compared their medium-term outcomes.
Hypotheses: Our main hypothesis would be that the Pyrocardan® implant, by preserving the carpal biomechanics, could lead to better wrist mobility. Our secondary hypotheses would be that no other clinical and radiological differences will be found between these two procedures at a mean 5 years follow-up.
Odour imagery, the ability to experience smell when an appropriate stimulus is absent, has widely been documented as being particularly difficult. However, previous studies have shown the beneficial effect of visual cues (e.g.
View Article and Find Full Text PDFPurpose: The purpose of this study was to evaluate the ability of ultra-high-resolution computed tomography (UHR-CT) to assess stapes and chorda tympani nerve anatomy using a deep learning (DLR), a model-based, and a hybrid iterative reconstruction algorithm compared to simulated conventional CT.
Materials And Methods: CT acquisitions were performed with a Mercury 4.0 phantom.
Objective(s): To determine the frequency of olfactory cleft (OC) stenosis and obstruction on paranasal sinus CT scans in pre-septorhinoplasty of patients who had septal deviation, septopyramidal deformation or nasal obstruction without other sinonasal conditions.
Methods: This retrospective study included patients referred to our institution between December 2013 and December 2021 for septorhinoplasty due to nasal obstruction without other sinonasal or neurological conditions. All patients underwent preoperative paranasal sinus CT scan and olfactory testing.
Focal bone lesions are frequent, and management greatly depends on the characteristics of their images. After briefly discussing the required work-up, we analyze the most relevant imaging signs for assessing potential aggressiveness. We also describe the imaging aspects of the various types of lesion matrices and their clinical implications.
View Article and Find Full Text PDFSemin Musculoskelet Radiol
August 2023
Bone microarchitecture has several clinical implications over and above estimating bone strength. Computed tomography (CT) analysis mainly uses high-resolution peripheral quantitative CT and micro-CT, research imaging techniques, most often limited to peripheral skeleton assessment. Ultra-high-resolution (UHR) CT and photon-counting detector CT, two commercially available techniques, provide images that can approach the spatial resolution of the trabeculae, bringing bone microarchitecture analysis into clinical practice and improving depiction of bone vascularization, tumor matrix, and cortical and periosteal bone.
View Article and Find Full Text PDFBackground Initial imaging work-up using radiography and CT arthrography sometimes can be insufficient to identify a scapholunate (SL) instability (SLI) in patients suspected of having SL ligament tears. Purpose To determine the diagnostic performance of four-dimensional (4D) CT in the identification of SLI and apply the findings to patients suspected of having SLI and with inconclusive findings on radiographs and CT arthrograms. Materials and Methods This prospective single-center study enrolled participants suspected of having SLI (recent trauma, dorsal pain, positive Watson test results, decreased grip strength) between March 2015 and March 2020.
View Article and Find Full Text PDFIntroduction: Adnexal torsion is a surgical emergency and its prognosis depends on the time elapsed prior to treatment. The diagnosis relies on pelvic ultrasound in which sensitivity remains low and may lead to misdiagnosis.The primary objective is to evaluate the diagnostic performance of contrast-enhanced ultrasound for the diagnosis of adnexal torsion in women with suspected adnexal torsion.
View Article and Find Full Text PDFObjectives: Evaluate the prevalence of radiological anomalies on orthopantomograms (OPT) performed as part of forensic age estimation in unaccompanied minors.
Methods: This is a retrospective study conducted on 208 OPT examinations requested by a magistrate. These OPTs were interpreted independently by two readers to establish the number of missing teeth (MT), presence of dental fillings (DF), and dental anomalies (DA).
Purpose: The purpose of this study was to evaluate the ability to depict in vivo bone vascularization using ultra-high-resolution (UHR) computed tomography (CT) with deep learning reconstruction (DLR) and hybrid iterative reconstruction algorithm, compared to simulated conventional CT, using osteoid osteoma as a model.
Materials And Methods: Patients with histopathologically proven cortical osteoid osteoma who underwent UHR-CT between October 2019 and October 2022 were retrospectively included. Images were acquired with a 1024 × 1024 matrix and reconstructed with DLR and hybrid iterative reconstruction algorithm.
Objectives: To qualitatively and quantitatively compare a single breath-hold fast half-Fourier single-shot turbo spin echo sequence with deep learning reconstruction (DL HASTE) with T2-weighted BLADE sequence for liver MRI at 3 T.
Methods: From December 2020 to January 2021, patients with liver MRI were prospectively included. For qualitative analysis, sequence quality, presence of artifacts, conspicuity, and presumed nature of the smallest lesion were assessed using the chi-squared and McNemar tests.
Connectivity studies with nuclear medicine systems are scarce in literature. They mainly employ PET imaging and group level analyses due to the low temporal resolution of PET and especially SPECT imaging. Our current study analyses connectivity at an individual level using dynamic SPECT imaging, which has been enabled by the improved temporal resolution performances provided by the 360°CZT cameras.
View Article and Find Full Text PDFThe purpose of this study was to report the outcomes of flexor tendon repair in zone II and compare two analytic tests - the original and adjusted Strickland scores - and a global hand function test, the 400-points test. We included 31 consecutive patients (35 fingers) with a mean age of 36 years (range 19-82 years) who underwent surgery for a flexor tendon repair in zone II. All patients were treated in the same healthcare facility by the same surgical team.
View Article and Find Full Text PDFObjective: To compare the diagnostic performance of standard MRI and standard MRI + ZTE images for the detection of rotator cuff calcific tendinopathy (RCCT) and to describe the artifacts encountered with ZTE images, using computed radiography (CR) as a reference.
Methods: In a retrospective study, patients with suspicion of rotator cuff tendinopathy who underwent standard MRI + ZTE images after radiography were enrolled between June 2021 and June 2022. Images were independently analyzed for calcific deposit presence and ZTE images artifacts, by two radiologists.